Carrier ESTRELLA

Ìwé Ìtọ́sọ́nà Olùlò AC ESTRELLA PRO Fèrèsé 1 Tọ́n 3

Model: ESTRELLA PRO

1. Ifihan

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Carrier 1 Ton 3 Star Window AC, model ESTRELLA PRO. Please read this manual thoroughly before using the air conditioner and retain it for future reference.

Carrier 1 Ton 3 Star Window AC ESTRELLA PRO

Image 1.1: Carrier 1 Ton 3 Star Window AC ESTRELLA PRO. This image shows the front view of the white window air conditioner unit.

2. Alaye Aabo

Nigbagbogbo tẹle awọn iṣọra aabo ipilẹ nigba lilo awọn ohun elo itanna lati dinku eewu ina, mọnamọna, tabi ipalara.

  • Rí i dájú pé agbára ìpèsè náà bá àmì ìdíyelé tí ó wà lórí ẹ̀rọ náà mu.
  • Do not operate the AC with wet hands or when standing on a wet surface.
  • Ma ṣe fi awọn ika ọwọ tabi awọn nkan sii sinu ẹnu-ọna afẹfẹ / iṣan.
  • Pa awọn ọmọde kuro ni ẹyọkan.
  • Ge asopọ agbara ṣaaju ṣiṣe afọmọ tabi ṣiṣe.
  • Má ṣe gbìyànjú láti tún ẹ̀rọ náà ṣe fúnra rẹ. Pe àwọn òṣìṣẹ́ iṣẹ́ tó péye.

3. Eto

3.1 Ṣiṣii silẹ

Carefully remove the air conditioner from its packaging. Inspect the unit for any damage that may have occurred during shipping. Retain packaging materials for future transport or storage.

3.2 fifi sori ẹrọ

This window air conditioner requires proper installation in a suitable window opening. Ọjọgbọn fifi sori wa ni gíga niyanju to ensure correct placement, sealing, and electrical connection. Incorrect installation can lead to reduced performance, water leakage, or safety hazards. Amazon will raise an installation/demo request on your behalf within 24 hours of delivery. If you do not receive a confirmation call from the brand within this time, please contact the support number provided in the Warranty & Support section.

3.3 Asopọ agbara

Connect the power cord to a dedicated electrical outlet that meets the unit's power requirements (230 Volts). Do not use extension cords or adapter plugs, as these can pose a fire hazard.

4. Awọn ilana Iṣiṣẹ

4.1 Iṣakoso latọna jijin Loriview

The air conditioner is operated using the provided remote control. Insert two AAA batteries (not included) into the remote control. Point the remote control directly at the indoor unit when operating. Note that the remote control for this model does not display the current room temperature.

4.2 Basic Modes

  • Ipo Itura: Press the MODE button until the COOL indicator appears. Use the temperature adjustment buttons to set your desired temperature.
  • Ipo Ipele: Press the MODE button until the FAN indicator appears. The unit will circulate air without cooling. Adjust fan speed as desired.
  • Ipo gbigbẹ: Press the MODE button until the DRY indicator appears. This mode helps to reduce humidity in the room.

4.3 Atunṣe iwọn otutu

Lo awọn ati buttons on the remote control to increase or decrease the desired temperature setting. The adjustable range is typically between 16°C and 30°C.

4.4 Iyara Fan

Press the FAN SPEED button to cycle through available fan speeds: Low, Medium, High, and Auto. Auto fan speed adjusts automatically based on the room temperature.

4.5 Ipo orun

Activate Sleep Mode for comfortable overnight operation. In this mode, the set temperature will gradually increase by 1°C after the first hour and another 1°C after the second hour, maintaining a comfortable sleeping environment while conserving energy.

4.6 Anti Bacterial Filter

This unit is equipped with an Anti Bacterial Filter designed to help provide cleaner air. Regular cleaning of this filter is essential for optimal performance and air quality.

5. Itọju

Regular maintenance ensures efficient operation and extends the lifespan of your air conditioner. Always disconnect power before performing any maintenance.

5.1 Air Filter Cleaning

The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. To clean:

  1. Ṣí iwájú pátákó náà.
  2. Fara yọ afẹfẹ kuro.
  3. Fi omi gbígbóná àti ọṣẹ ìfọṣọ díẹ̀ fọ àlẹ̀mọ́ náà. Fi omi wẹ̀ ẹ́ dáadáa.
  4. Gba àlẹmọ laaye lati gbẹ patapata ṣaaju fifi sori ẹrọ. Ma ṣe fi si imọlẹ orun taara.
  5. Reinstall the dry filter and close the front panel.

5.2 Gbogbogbo Cleaning

Mu ese ita kuro pẹlu asọ, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure no water enters the electrical components.

5.3 Ibi ipamọ akoko

Ti o ba tọju ẹyọ naa fun igba pipẹ:

  • Ṣiṣẹ ẹrọ naa ni ipo Fan fun wakati diẹ lati gbẹ awọn paati inu.
  • Mọ àlẹmọ afẹfẹ ati ita.
  • Ge asopọ okun agbara.
  • Cover the unit to protect it from dust and store it in a dry place.

6. Laasigbotitusita

Ṣaaju ki o to kan si iṣẹ, tunview Awọn iṣoro ti o wọpọ ati awọn solusan wọnyi:

Isoro Owun to le Fa Ojutu
AC ko ni tan Kò sí agbára, ẹ̀rọ ìdènà ìṣiṣẹ́ tí ó ti bàjẹ́, ìsopọ̀ tí ó dẹ́kun. Ṣàyẹ̀wò okùn agbára, tún ẹ̀rọ ìdènà ìṣiṣẹ́ náà ṣe, rí i dájú pé o so mọ́ra dáadáa.
Itutu agbaiye ti ko to Dirty air filter, blocked air intake/outlet, room too large, doors/windows open, low refrigerant. Clean air filter, clear obstructions, ensure proper room size, close doors/windows. If refrigerant is low, contact service.
Unit jẹ alariwo Loose parts, fan obstruction, unit not level. Check for loose components, clear obstructions, ensure unit is level.
Omi jijo Improper installation, clogged drain pan. Ensure proper tilt during installation. Clear drain pan. Contact service if issue persists.

If the problem persists after attempting these solutions, or if you suspect a refrigerant leak, disconnect the power and contact authorized service personnel.

7. Awọn pato

Brand Olugbeja
Awoṣe ESTRELLA PRO
Agbara 1 Toonu
Lilo Agbara 3 Star BEE Rating
Agbara Itutu 3550 Wattis
Ariwo Ipele 49 Decibels
Iru fifi sori ẹrọ Ferese
Pataki Ẹya Àlẹmọ Anti Bakteria
Ohun elo Copper (Coil)
Voltage 230 Volts
Iwọn Nkan 39 kg
Awọn iwọn (LxWxH) 67.4 x 61.5 x 41.8 centimeters
Awọn irinše to wa 1 main unit and warranty card

8. Atilẹyin ọja & Atilẹyin

8.1 Atilẹyin ọja

This Carrier air conditioner comes with a 1 Odun atilẹyin ọja. Jọwọ tọkasi kaadi atilẹyin ọja ti o wa pẹlu ọja rẹ fun awọn ofin ati ipo ni kikun. Note: Warranty coverage may be dependent on installation by a certified Carrier technician.

8.2 Onibara Support

For any queries, installation requests, or technical assistance, please contact Carrier customer support:

Awọn iwe aṣẹ ti o jọmọ - ESTRELLA

Ṣaajuview Àwọn ìlànà ìfi sori ẹ̀rọ CRFLTTRK001A00 fún ẹ̀rọ alábọ́ọ́dé fún ẹ̀rọ orí òrùlé.
Detailed installation instructions for the Carrier CRFLTTRK001A00 accessory filter kit, designed for medium rooftop units (12.5 to 27.5 tons). Includes package contents, safety precautions, general information, model compatibility, and step-by-step installation procedures.
Ṣaajuview Carrier WeatherMaker® 48TC Orí Ilé HVAC: Dátà Ọjà Ìtutù Gáàsì/Iná mànàmáná
Explore the Carrier WeatherMaker® 48TC series of packaged rooftop units, offering gas heat and electric cooling for 6 to 15 nominal tons. This product data document details specifications, performance, options, and applications for efficient commercial HVAC solutions.
Ṣaajuview Àwọn ohun èlò ìfọṣọ tí a fi omi tútù ṣe tí ó ń gbé ọkọ̀ ayọ́kẹ́lẹ́ 30BAW Series (18-50 tọ́ọ̀nù) - Àwọn ẹ̀kúnrẹ́rẹ́ ìmọ̀-ẹ̀rọ àti àwọn ẹ̀yà ara rẹ̀
Detailed technical specifications, features, and diagrams for the Carrier 30BAW Series of water-cooled scroll chillers, ranging from 18 to 50 tons. Includes model nomenclature, general features, compressor details, heat exchanger information, protection functions, wiring diagrams, piping diagrams, dimensions, and unit conversions.
Ṣaajuview Carrier 25HCS3 Comfort Series Heat Pump Wiring Diagrams - 1.5 to 5 Tons
Comprehensive wiring diagrams for the Carrier 25HCS3 Comfort Series Heat Pump, covering models from 1 1/2 to 5 nominal tons using Puron® refrigerant. Includes connection diagrams, schematic diagrams (ladder form), a detailed legend of components and wiring, important notes, and DIP switch settings for defrost cycle configuration.
Ṣaajuview Installation Instructions: Manual Damper Accessory for Vertical and Horizontal Applications
Detailed installation instructions for Carrier's Manual Damper Accessory, designed for vertical and horizontal HVAC applications. Includes safety precautions, package contents, and step-by-step assembly guidance.
Ṣaajuview Packaged Air-Handling Units Duct Adapter Installation Instructions
Comprehensive installation instructions for Carrier, Bryant, and ICP 6 to 10 ton packaged air-handling unit duct adapter accessories (Part No. CADUCADP001A00). Includes safety, pre-installation, installation, start-up, and service information.