1. Ifihan

The Weintek MT8100iE is a 10.2-inch Human Machine Interface (HMI) designed for industrial automation applications. It features an 800 x 480 TFT industrial-grade LCD and is built to fully support major PLCs such as Rockwell, Siemens, Mitsubishi, and Omron. This manual provides essential information for the proper installation, operation, and maintenance of your MT8100iE HMI.

2. Alaye Aabo

Please read and understand all safety instructions before operating the device. Failure to comply may result in injury or damage to the equipment.

  • Rí i dájú pé a ti ge ina agbara kuro kí a tó ṣe ìfisí tàbí ìtọ́jú èyíkéyìí.
  • Àwọn òṣìṣẹ́ tó ní ìmọ̀ nìkan ló yẹ kí wọ́n fi ẹ̀rọ yìí sí àti ṣe àtúnṣe rẹ̀.
  • Ma ṣe fi ẹrọ naa han si ọrinrin ti o pọ ju, eruku, tabi awọn iwọn otutu to gaju.
  • Verify correct wiring and connections to prevent electrical hazards.
  • The front panel is NEMA4/IP65 compliant, but ensure proper sealing during installation to maintain this rating.

3. Package Awọn akoonu

Jẹrisi pe gbogbo awọn ohun kan wa ninu package:

  • MT8100iE HMI Unit
  • Àwọn Báàkẹ́ẹ̀tì Ìfìsórí (4x)
  • Asopọ agbara
  • Afowoyi Olumulo (iwe-ipamọ yii)
  • CD-ROM with EasyBuilder Pro Software (or download link)

4. Ọja Ipariview

Familiarize yourself with the components and interfaces of the MT8100iE HMI.

4.1 Iwaju View

Iwaju view of the Weintek MT8100iE HMI displaying an industrial boiler control system interface.

olusin 4.1: Iwaju view of the MT8100iE HMI, showing the 10.2-inch TFT LCD touchscreen and the power indicator LED at the top left.

4.2 Ẹgbẹ View

Pro ẹgbẹfile of the Weintek MT8100iE HMI, showing its slim design.

olusin 4.2: Ẹgbẹ profile of the MT8100iE, illustrating its compact form factor suitable for panel mounting.

4.3 Ẹyìn View

Ẹyìn view of the Weintek MT8100iE HMI, showing mounting points, fuse holder, and reset button.

olusin 4.3: Ẹyìn view of the MT8100iE, highlighting the mounting holes for panel installation, the fuse holder for power protection, and the system reset button.

4.4 Communication Ports

Isalẹ view of the Weintek MT8100iE HMI showing USB, Ethernet, and serial communication ports.

olusin 4.4: Isalẹ view of the MT8100iE, detailing the various communication ports including USB, Ethernet, COM1 (RS-232), and COM2 (RS-485 2W/4W).

5. Eto

5.1 Panel iṣagbesori

  1. Cut an opening in the control panel according to the dimensions provided in the installation guide (refer to the separate installation template for precise measurements).
  2. Insert the MT8100iE HMI into the cutout from the front.
  3. From the rear of the panel, insert the four mounting brackets into the slots on the HMI unit.
  4. Tighten the screws on the mounting brackets evenly until the HMI is securely fastened to the panel. Do not overtighten.

5.2 Asopọ agbara

  • Connect a 24V DC power supply to the power input terminal block on the rear of the HMI.
  • Ensure correct polarity (+ and -).
  • Secure the connection firmly.

5.3 Awọn isopọ ibaraẹnisọrọ

  • Tẹlentẹle Awọn ibudo: Use the COM1 (RS-232) and COM2 (RS-485 2W/4W) ports to connect to PLCs or other serial devices. Refer to your PLC's documentation for specific wiring diagrams.
  • Àjọlò Port: Connect an Ethernet cable to the RJ45 port for network communication with PLCs or for remote access.
  • Awọn ibudo USB: Use the USB host ports for connecting USB flash drives for project transfers or other peripherals.

6. Awọn ilana Iṣiṣẹ

6.1 Agbara Lori

Once all connections are secure, apply power to the HMI. The power indicator LED will illuminate, and the HMI will boot up, displaying the configured project.

6.2 Project Download

To load a new project or update an existing one:

  1. Create or modify your HMI project using the EasyBuilder Pro software on a PC.
  2. Connect the PC to the HMI via Ethernet or USB.
  3. In EasyBuilder Pro, use the 'Download' function to transfer the project to the HMI.
  4. The HMI will restart with the new project loaded.

6.3 Touchscreen isẹ

The MT8100iE features a resistive touchscreen. Use your finger or a non-sharp stylus to interact with the on-screen elements such as buttons, input fields, and displays.

6.4 PLC Communication

The HMI is designed to communicate with various PLCs. Ensure the communication settings (protocol, baud rate, station ID, etc.) configured in your EasyBuilder Pro project match those of your connected PLC.

7. Itọju

Regular maintenance ensures optimal performance and longevity of your HMI.

  • Ninu: Lo asọ, damp cloth to clean the screen and casing. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
  • Awọn imudojuiwọn famuwia: Periodically check the Weintek website for firmware updates to ensure your HMI has the latest features and bug fixes.
  • Rirọpo Fuse: If the HMI does not power on, check the fuse located on the rear panel. Replace it with a fuse of the same type and rating if necessary. Always disconnect power before replacing the fuse.
  • Awọn ipo Ayika: Rí i dájú pé àyíká iṣẹ́ náà wà láàrín ìwọ̀n otutu àti ọriniinitutu tí a sọ tẹ́lẹ̀ láti dènà ìbàjẹ́.

8. Laasigbotitusita

Abala yii n pese awọn ojutu si awọn ọran ti o wọpọ ti o le ba pade.

IsoroOwun to le FaOjutu
HMI ko ṣiṣẹ.No power supply, incorrect wiring, blown fuse.Check power connection, verify wiring polarity, replace fuse if blown.
Iboju ifọwọkan ko dahun.Screen calibration issue, hardware fault.Perform screen calibration (refer to EasyBuilder Pro documentation), contact support if issue persists.
Cannot communicate with PLC.Incorrect communication settings, wrong cable, PLC offline.Verify communication protocol, baud rate, and station ID in EasyBuilder Pro. Check cable connections. Ensure PLC is powered on and running.
Project download fails.Network issue, incorrect IP address, firewall blocking.Check network cable, verify HMI and PC IP addresses are in the same subnet. Temporarily disable firewalls for testing.

9. Awọn pato

Ẹya ara ẹrọApejuwe
Nọmba awoṣeeMT3070A1WK
Iwon iboju10.2 inches
Ipinnu800 x 480
Apakan Ipin1.66:1
Iboju IbojuDidan
Iranti-Itumọ ti ni 128 MB Flash Memory
Aago gidi-gidi (RTC)Bẹẹni
Iwaju Panel RatingNEMA4/IP65 Compliant
Serial PortsCOM1 RS-232 / COM2 RS-485 (2W/4W)
Ifitonileti ImeeliStatus e-Mail notification feature

10. Atilẹyin ọja ati Support

Weintek products are manufactured to high quality standards. For warranty information and technical support, please refer to the official Weintek website or contact your authorized distributor. Keep your purchase receipt as proof of purchase for warranty claims.

For software downloads, drivers, and additional resources, visit the official Weintek support portal.

Awọn iwe aṣẹ ti o jọmọ - eMT3070A1WK

Ṣaajuview WEINTEK cMT3106XM Handheld HMI Datasheet | Specifications & Features
Detailed datasheet for the WEINTEK cMT3106XM 10.1-inch WVA Handheld HMI. Explore features, technical specifications, environmental ratings, and ordering information.
Ṣaajuview Weintek cMT2108X2 10.1-inch TFT HMI - Datasheet and Specifications
Detailed datasheet for the Weintek cMT2108X2, a 10.1-inch TFT HMI with 1024x600 resolution, 4GB flash memory, and industrial-grade features. Includes specifications, dimensions, and ordering information.
Ṣaajuview WEINTEK MODBUS RTU, RTU over TCP PLC Connection Guide
Technical guide from WEINTEK detailing the configuration and connection of HMIs using MODBUS RTU and RTU over TCP protocols. Covers HMI and PLC settings, device addressing, wiring diagrams, and Modbus RTU function codes for industrial automation.
Ṣaajuview Weintek cMT-G02X Series HMI Awọn ilana fifi sori ẹrọ
Awọn ilana fifi sori ẹrọ ni kikun fun Weintek cMT-G02X Series HMI, tito eto ayika, agbara ati awọn asopọ ibaraẹnisọrọ, iṣeto ni sọfitiwia, awọn iṣọra ailewu, ati alaye atilẹyin ọja.
Ṣaajuview Weintek cMT-CTRL01 Series HMI Installation Guide
Installation instructions for the Weintek cMT-CTRL01 Series HMI. This guide covers environmental setup, unpacking, physical installation, power and communication connections, system settings, LED indicators, reset procedures, battery replacement, and warranty information. Designed for industrial automation professionals.
Ṣaajuview cMT-G05X Series fifi sori ilana | Weintek HMI
Awọn ilana fifi sori ẹrọ osise fun Weintek cMT-G05X Series HMI. Ni wiwa iṣeto, ayika, awọn asopọ agbara, awọn eto eto, ibaraẹnisọrọ, sọfitiwia, ati atilẹyin ọja.