1. Ifihan
The Greenlee CM-660 is a general-purpose AC True RMS clamp meter designed for accurate electrical measurements. This instrument is capable of measuring AC currents, DC voltages, resistance, and frequency. It incorporates a digital low-pass filter for precise readings on variable frequency drives (VFDs) and features AmpTip™ technology for enhanced accuracy on small wires carrying low currents (60 amps tabi kere si).
Key features include non-contact AC voltage detection, continuity testing, and diode testing. The meter can record average, maximum, and minimum readings, and offers two voltage detection modes: non-contact or single test lead. It is powered by two 1.5V AAA batteries and comes with test leads and a carrying case for convenience. The CM-660 has a 6000-count LCD display and a 1.18-inch jaw opening. It is UL listed, ensuring compliance with safety standards.

Figure 1.1: Greenlee CM-660 General Purpose AC Clamp Mita.
2. Alaye Aabo
Always adhere to safety precautions when using electrical test equipment. Failure to do so may result in injury or damage to the meter.
- Ka Awọn ilana: Read and understand all instructions and safety information before operating the meter.
- Oṣiṣẹ ti o peye: This meter should only be used by qualified personnel who are familiar with electrical hazards.
- Ohun elo Idaabobo Ti ara ẹni (PPE): Always wear appropriate PPE, including safety glasses and insulated gloves, when working with electrical circuits.
- Voltage Awọn ifilelẹ: Maṣe kọja iwọn ti o pọjutage ratings specified for the meter (600 VAC/DC).
- Awọn opin lọwọlọwọ: Do not exceed the maximum current ratings (600 Amps).
- Ṣayẹwo awọn itọsọna idanwo: Before each use, inspect test leads for damage. Do not use if insulation is cracked or if the conductor is exposed.
- Non-Olubasọrọ Voltage Iwari: Use non-contact voltage detection as a preliminary check only. Always verify with direct contact measurements.
- Rirọpo Batiri: Ensure the meter is disconnected from all circuits before opening the battery compartment.
- Awọn ipo Ayika: Do not use the meter in wet conditions or in the presence of explosive gases or dust.
- Proper Function: If the meter appears to be damaged or is not operating correctly, discontinue use immediately.
3. Eto
3.1 Fifi sori batiri
The Greenlee CM-660 requires two 1.5V AAA batteries for operation. These are typically included with the meter.
- Ensure the meter is turned OFF and disconnected from any electrical circuits.
- Wa ideri ibi ipamọ batiri naa ni ẹhin mita naa.
- Lo screwdriver lati tú dabaru ti o ni aabo ideri batiri naa.
- Remove the cover and insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Ropo ideri batiri ki o si Mu dabaru ni aabo.
3.2 Ibẹrẹ Ayẹwo
Before first use, and periodically thereafter, perform a visual inspection of the meter and its accessories.
- Check the meter casing for any cracks, damage, or signs of wear.
- Inspect the test leads for frayed insulation, exposed wires, or damaged connectors.
- Ensure the jaw mechanism opens and closes smoothly and securely.
- Verify the display is clear and free from defects when the meter is powered on.

Figure 3.1: Included test leads and carrying case.
4. Awọn ilana Iṣiṣẹ
The Greenlee CM-660 offers various measurement functions. Always select the appropriate function before making a measurement.
4.1 Mita Loriview

Figure 4.1: Diagram illustrating key features of the Greenlee CM-660 clamp meter, including the clamp jaw, AmpTip, non-contact AC voltagìwádìí e, ìdìpọ̀ ACtage with digital filter, over-molded grip, and display.
- Clamp Ẹrẹ: Used for non-contact AC current measurements.
- AmpTip™: Provides increased accuracy for low AC currents (60 amps or less) on small wires.
- Ṣiṣe ipe iṣẹ: Selects the desired measurement mode (AC Current, DC Voltage, Resistance, Frequency, Continuity, Diode).
- Ifihan: 6000-count LCD for clear reading of measurements.
- Àwọn Ìgbékalẹ̀ Ìdánwò: Ports for connecting test leads for voltage, resistance, continuity, and diode measurements.
- Non-olubasọrọ AC Voltage Iwari: Integrated sensor for detecting live AC voltage lai taara olubasọrọ.
- Digital Low Pass Filter: Improves accuracy when measuring AC voltage on variable frequency drives.
4.2 Wiwọn Okun AC (Cl)amp)
- Turn the function dial to the AC current (A~) position.
- Ṣii clamp ẹnu nípa títẹ lefa náà.
- So adarí kan ṣoṣo mọ́ cl náàamp jaw. Ensure the jaw is fully closed around the conductor.
- Ka iye AC lọwọlọwọ lori ifihan.
- For small wires carrying 60 amps or less, the AmpTip™ feature automatically provides increased accuracy.

Figure 4.2: The CM-660 clamp meter in use, measuring current by clamping ni ayika kan nikan adaorin.
4.3 Idiwon DC Voltage
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the DC voltage (V=) position.
- So asiwaju idanwo pupa naa pọ mọ apa rere ti iyipo naa ati asiwaju idanwo dudu naa si apa odi.
- Ka DC voltage iye lori ifihan.
4.4 Idiwọn Resistance
- Rii daju pe iyika naa ti ni agbara ṣaaju idiwọn resistance.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Resistance (Ω) position.
- So awọn itọsọna idanwo kọja paati tabi iyika lati wọn.
- Ka iye resistance lori ifihan.
4.5 Igbeyewo Ilọsiwaju
- Rí i dájú pé agbára ìṣiṣẹ́ náà ti dínkù kí o tó ṣe ìdánwò ìtẹ̀síwájú.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Continuity (Buzzer symbol) position.
- So awọn itọsọna idanwo kọja Circuit tabi paati.
- The meter will emit an audible tone if continuity is detected (low resistance).
4.6 Idanwo Diode
- Ensure the circuit is de-energized before performing a diode test.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Diode (Diode symbol) position.
- So asiwaju igbeyewo pupa pọ si anode ati asiwaju idanwo dudu si cathode ti diode.
- Awọn àpapọ yoo fi awọn siwaju voltage drop. Reverse the leads; the display should show "OL" (Open Line) for a good diode.
4.7 Non-olubasọrọ AC Voltage Iwari
- Turn the function dial to the NCV (Non-Contact Voltage) ipo.
- Hold the meter with the NCV sensor near the conductor or outlet.
- Ti AC voltage is present, the meter will indicate with an audible beep and/or visual indicator.
- IKILO: This feature is for preliminary detection only. Always verify voltage presence and magnitude with direct contact measurements using test leads.
5. Itọju
Proper maintenance ensures the longevity and accuracy of your Greenlee CM-660 clamp mita.
5.1 Ninu
- Nu mita naa casing pẹlu ipolowoamp asọ ati ìwọnba detergent. Ma ṣe lo abrasive ose tabi epo.
- Ensure no moisture enters the meter's openings.
- Clean the test leads regularly, especially the probe tips, to ensure good electrical contact.
5.2 Batiri Rirọpo
Refer to Section 3.1 for battery installation instructions. Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings.
5.3 Ibi ipamọ
- Tọ́jú ìwọ̀n mita náà sínú àpótí ìrù rẹ̀ nígbà tí o kò bá lò ó láti dáàbò bò ó kúrò lọ́wọ́ eruku àti ìbàjẹ́ ara.
- If storing for extended periods, remove the batteries to prevent leakage.
- Store in a cool, dry environment, away from direct sunlight and extreme temperatures.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Mita ko ni agbara lori. | Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ. | Ṣayẹwo polarity batiri; ropo awọn batiri. |
| "OL" (Overload) ni a fihan. | Wíwọ̀n náà kọjá ìwọ̀n mítà. | Ensure the measurement is within the meter's specified range. |
| Awọn kika ti ko pe. |
|
|
| Ko si ohun orin ilosiwaju. |
|
|
7. Awọn pato
The following table outlines the key specifications for the Greenlee CM-660 General Purpose AC Clamp Mita.
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | CM-660 |
| Orisi wiwọn | AC Current, DC Voltage, Resistance, Frequency, Continuity, Diode |
| AC Lọwọlọwọ Range | Titi di 600 Amps |
| DC Voltage Ibiti | Titi di 600 VDC |
| AC Voltage Ibiti | Titi di 600 VAC |
| Resistance Range | Up to 60 kΩ |
| Iwọn Igbohunsafẹfẹ | 50/60 Hz (voltage/AmpTip currents), 50-400 Hz (higher currents) |
| Ifihan | 6000 Count LCD |
| Ibẹrẹ ẹnu | 1.18 inches (30 mm) |
| Orisun agbara | 2 x 1.5V AAA Awọn batiri |
| Aabo Rating | UL Listed, CAT IV 300V, CAT III 600V |
| Awọn iwọn (L x W x H) | 5.5 x 11.4 x 2.2 inches (isunmọ) |
| Iwọn Nkan | 16 iwon (1 iwon) |
| Pataki Awọn ẹya ara ẹrọ | AmpTip™, Digital Low Pass Filter, Non-Contact AC Voltage Detection, Max/Min/Avg Recording, Data Hold, Auto Power Off |

Figure 7.1: Approximate dimensions of the CM-660 clamp meter shown in hand for scale.
8. Atilẹyin ọja & Atilẹyin
8.1 atilẹyin ọja Alaye
Greenlee products are manufactured to high standards and are backed by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions applicable to your CM-660 clamp meter, please refer to the warranty card included with your product or visit the official Greenlee webojula. Jeki ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.
8.2 Onibara Support
For technical assistance, troubleshooting, or service inquiries, please contact Greenlee customer support. Contact information can typically be found on the Greenlee webaaye tabi ni apoti ọja.
Awọn orisun Ayelujara: For additional product information, FAQs, and support, visit the official Greenlee webojula: www.greenlee.com
Product Videos and Demonstrations: For product videos and demonstrations, you may visit the link provided in some product documentation: http://tagr.com/t/V3v6VF