This manual provides essential information for the safe and efficient operation of your Intermatic HB112 Heavy-Duty 240 VAC Timer. This energy-saving, heavy-duty appliance timer is designed to plug directly into a wall outlet and control 240-volt air conditioners, heaters, and other heavy-duty appliances and lamps. It features a 3600-watt capacity and a manual override switch for convenience.
Alaye Aabo pataki
Please read and understand all instructions before installing or operating this timer. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ewu Itanna: This device operates on 240 Volts. Installation and servicing should only be performed by qualified personnel.
- Ilẹ: Ensure the timer is properly grounded using its 3-prong grounded plug and receptacle.
- Agbara fifuye: Do not exceed the maximum load capacity of 3600 watts or 2 HP motor loads. Overloading can cause overheating and fire.
- Ayika: This timer is designed for indoor use. Avoid exposure to water or extreme moisture.
- Awọn ọmọde: Jeki kuro ni arọwọto awọn ọmọde.
Package Awọn akoonu
Rii daju pe gbogbo awọn nkan wa lori ṣiṣi silẹ:
- Intermatic HB112 Timer Unit
- Itọsọna itọnisọna
Ọja Pariview

Figure 1: Intermatic HB112 Heavy-Duty 240 VAC Timer. The image shows a white, rectangular timer unit with a black 3-prong plug extending from its left side. The front features a large, circular mechanical dial with numbers from 1 to 12 (AM/PM) and smaller segments. Two red pins are visible on the dial, indicating ON/OFF settings. The text 'INTERMATIC' and 'HEAVY DUTY TIME-ALL®' are printed on the timer's face. A black manual override switch is located at the bottom right of the dial.
The Intermatic HB112 timer features a robust design for controlling high-power appliances. Key components include:
- Mechanical Dial: A 24-hour rotating dial used to set the current time and program ON/OFF cycles.
- Push Segments (Pins): Small, black segments around the dial that are pushed down to set desired ON times and pulled up for OFF times. The timer supports 2 ON/2 OFF settings per day.
- Yipada Yipada Afọwọṣe: A switch located on the side or bottom of the unit that allows you to manually turn the connected appliance ON or OFF, bypassing the programmed settings.
- 3-Prong Grounded Plug and Receptacle: Ensures safe electrical connection for 240-volt appliances.
Awọn pato
| Olupese | Intermatic |
| Nọmba apakan | HB112 |
| Nọmba Awoṣe Nkan | HB112 |
| Ọja Mefa | 6.35 x 7.62 x 11.11 cm |
| Iwọn Nkan | 249.48 g |
| Àwọ̀ | Funfun |
| Ohun elo | Ṣiṣu |
| Voltage | 240 Volts |
| Wattage Agbara | 3600 Wattis |
| Motor fifuye | 2 HP |
| Nkan Package opoiye | 1 |
| Iṣagbesori Iru | Plug-Ni Oke |
| Ijẹrisi | CSA, UL |
| Awọn batiri To wa? | Rara |
| Ti beere awọn batiri? | Rara |
Ṣeto
- Jẹrisi Voltage: Ensure your appliance and wall outlet are rated for 240 Volts. This timer is designed for 240 VAC applications only.
- Plug In Timer: Insert the 3-prong grounded plug of the HB112 timer directly into a compatible 240-volt wall receptacle.
- Ohun elo Sopọ: Plug your 240-volt appliance into the receptacle on the timer. Ensure the appliance's wattage and HP rating do not exceed the timer's capacity (3600 watts, 2 HP).
- Ṣeto Akoko lọwọlọwọ: Rotate the entire mechanical dial clockwise until the arrow (present time pointer) aligns with the current time of day. The dial is marked with AM and PM hours.
Awọn ilana Iṣiṣẹ
Setting ON/OFF Times
The timer allows for up to 2 ON and 2 OFF settings per 24-hour period using the black push segments (pins) around the dial.
- Ṣe idanimọ awọn pinni: The dial has small black segments. Each segment represents 15 minutes.
- Ṣètò Àkókò Tí Ó Ń SÍ: Push down the segments corresponding to the desired time you want the appliance to turn ON. For example, to turn ON at 6:00 AM, push down the four segments between 5:45 AM and 6:00 AM.
- Àkókò Ṣíṣí: Pull up the segments corresponding to the desired time you want the appliance to turn OFF. For example, to turn OFF at 8:00 AM, pull up the four segments between 7:45 AM and 8:00 AM.
- Minimum ON/OFF Duration: Ensure a minimum of 45 minutes between ON and OFF settings for reliable operation.
Idojukọ Afowoyi
The HB112 timer includes a manual override switch, typically located on the side or bottom of the unit. This switch allows you to temporarily bypass the programmed settings.
- LORI Ipo: Move the switch to the 'ON' position to keep the appliance continuously powered, regardless of the dial settings.
- PA Ipò: Move the switch to the 'OFF' position to keep the appliance continuously off, regardless of the dial settings.
- TIMER Position: Move the switch to the 'TIMER' position to allow the programmed ON/OFF cycles to operate.
Itoju
- Ninu: Wipe the timer with a dry, soft cloth. Do not use liquid cleaners or abrasive materials.
- Ibi ipamọ: Tọju aago naa ni ibi gbigbẹ, ti o tutu nigbati ko si ni lilo.
- Ko si Awọn apakan Iṣẹ Olumulo: Do not attempt to open or repair the timer. Refer servicing to qualified personnel.
Laasigbotitusita
- Appliance does not turn ON/OFF at programmed times:
- Ensure the manual override switch is set to 'TIMER'.
- Verify that the current time on the dial is correctly aligned with the present time.
- Check that the ON/OFF segments (pins) are correctly pushed down or pulled up for the desired times.
- Confirm the appliance is properly plugged into the timer and is functioning correctly.
- Timer stops operating after a power outage:
- This mechanical timer does not have an internal battery backup. After a power outage, you must manually reset the current time on the dial.
- Timer makes a faint humming noise:
- A faint humming noise is normal for mechanical timers as the internal motor operates the dial.
Atilẹyin ọja ati Support
The Intermatic HB112 Heavy-Duty 240 VAC Timer comes with a 1-odun atilẹyin ọja lati ọjọ ti o ra.
For technical support, troubleshooting assistance, or warranty claims, please contact Intermatic customer service through their official webaaye tabi alaye olubasọrọ ti a pese ninu iwe rira rẹ.