Ọja Pariview
The GoControl GC-TBZ48 Z-Wave Battery-Powered Smart Thermostat offers advanced control over your home's heating and cooling system. It is designed for easy installation and integrates seamlessly with Z-Wave hubs, providing remote access and smart automation capabilities. This thermostat can be powered by four AA batteries or an HVAC system's 24-volt AC C-wire.

Nọmba 1: Iwaju view of the GoControl Smart Thermostat, showing the LCD display and control buttons.
Key Awọn ẹya ara ẹrọ
- Z-Wave Compatibility: Works with most Z-Wave hubs, including 2GIG GC2 panel.
- Awọn aṣayan Agbara Meji: Can be powered by 4 AA batteries (up to 2 years) or a 24-volt AC C-wire.
- HVAC System Support: Compatible with standard HVAC systems (2-stage heat & 2-stage cool) and heat pump HVAC systems (3-stage heat & 2-stage cool).
- Eto ti o rọrun: Features a 7-character scrolling display for simplified programming.
- Iṣakoso ohun: Works with Alexa for voice control (hub and Alexa device sold separately).
- FLiRS Functionality: Supports Z-Wave FLiRS (Frequently Listening Routing Slave) for improved responsiveness.
- Firmware Upgradable: USB firmware upgrade capability.
Fifi sori ẹrọ ati Eto
1. Awọn iṣọra aabo
- Always turn off power to the HVAC system at the circuit breaker before installation.
- Rí i dájú pé ẹni tó tóótun ló ṣe gbogbo wáyà tí o bá ní iyèméjì.
- Tẹle gbogbo awọn koodu itanna agbegbe.
2. Iṣagbesori Thermostat
The thermostat can be wall-mounted or installed on a single-gang junction box. Choose a location away from direct sunlight, drafts, and heat sources for accurate temperature readings.
3. Awọn itọnisọna Wiring
The GC-TBZ48 supports both battery power and 24V AC C-wire power. Refer to the wiring diagrams below for common HVAC system configurations. Ensure wires are securely connected to the appropriate terminals.
- Standard HVAC Systems: Connect R, W, Y, G, C (if using C-wire).
- Heat Pump Systems: Connect R, O/B, Y, G, C (if using C-wire), W2/Aux.
Note: Detailed wiring diagrams are typically found in the full PDF user guide. For specific wiring, consult the document linked in the product information.
The product description mentions a user guide PDF: Itọsọna olumulo (PDF)
4. Fifi sori batiri
If not using the C-wire, install four AA alkaline batteries into the front-loading battery compartment. Ensure correct polarity. The thermostat is designed to operate for up to 2 years on battery power.
5. Pípọ̀mọ́ra Z-Wave
- Put your Z-Wave hub into inclusion/pairing mode.
- On the thermostat, navigate to the menu and select "Install" or "Pair".
- The thermostat will display a confirmation once successfully paired.
- Configure the thermostat mode (e.g., "Heat-pump" mode) via the thermostat menu or your Z-Wave controller as needed.
Ṣiṣẹ Thermostat
Awọn iṣakoso afọwọṣe
- Bọtini MODE: Cycles through system operating modes: Off, Heat, Cool, Auto.
- Bọtini FAN: Cycles through fan operation modes: Auto (fan runs only when heating/cooling) or On (fan runs continuously).
- Awọn itọka oke/isalẹ: Adjusts the temperature setpoint.
Z-igbi Iṣakoso
Once paired with a Z-Wave hub, you can control the thermostat remotely via your hub's interface or associated mobile application. This includes:
- Changing system mode (Heat, Cool, Auto, Off).
- Adjusting temperature setpoints.
- Setting fan mode.
- Creating schedules and automation rules (functionality depends on your Z-Wave hub).
Itoju
- Rirọpo Batiri: Replace AA batteries approximately every 2 years, or when the low battery indicator appears on the display. Use high-quality alkaline batteries.
- Ninu: Musẹ ita ita gbangba igbona pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
- Awọn imudojuiwọn famuwia: Check the GoControl website or your Z-Wave hub manufacturer's support pages for available firmware updates. The thermostat supports USB firmware upgrades.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Thermostat kò ṣiṣẹ́. | Dead batteries or no C-wire connection. | Replace batteries or verify C-wire connection and HVAC power. |
| A ko le so pọ mọ ibudo Z-Wave. | Hub not in inclusion mode, thermostat too far from hub, or interference. | Ensure hub is in inclusion mode. Move thermostat closer to hub. Check for Z-Wave network interference. Try excluding and re-including the device. |
| Eto HVAC ko dahun. | Incorrect wiring, HVAC power off, or thermostat mode incorrect. | Verify wiring connections. Check HVAC system's circuit breaker. Ensure thermostat is set to the correct system mode (Heat/Cool/Auto). |
| Kika iwọn otutu ti ko pe. | Ipo iwọn otutu ti o kan nipasẹ awọn iyaworan, oorun taara, tabi awọn orisun ooru. | Relocate thermostat if possible. Allow 15 minutes for sensor adjustment after installation or significant temperature changes. |
Awọn pato
- Orukọ awoṣe: GC-TBZ48
- Nọmba apakan: BRO-NTBZ48
- Brand: GoControl
- Asopọmọra: Z-Wave (Ver. 4.5.5), Z-Wave FLiRS
- Orisun Agbara: 4 AA batteries (included) or 24V AC C-wire
- Iru ifihan: LCD with 7-character scrolling display
- Awọn iwọn: 9.59 x 6.16 x 2.08 inches
- Ìwọ̀n Nkan: 1.15 iwon
- Ohun elo: Ṣiṣu
- Àwọ̀: Funfun
- Iru fifi sori: Wall Mount or Single-Gang Junction Box
- Awọn iwe-ẹri: UL Akojọ
- Awọn oludari ibaramu: Nexia, Vera, GoControl, Amazon Alexa (via compatible hub), SmartThings
Alaye atilẹyin ọja
The GoControl GC-TBZ48 Smart Thermostat comes with a 1-odun atilẹyin ọja against manufacturer defects. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official GoControl documentation or contact customer support.
Onibara Support
For technical assistance, troubleshooting, or warranty inquiries, please contact GoControl customer support. Refer to the GoControl official webojula fun awọn julọ lọwọlọwọ alaye olubasọrọ.
Awọn orisun Ayelujara:
- Official GoControl Website (for support contact and product information)
- Itọsọna olumulo (PDF): https://manuals.plus/m/9d31e8db4621f9c765178be18fb86e60397d995b2bbf0055524db570ec6b144d