Ọrọ Iṣaaju
This manual provides essential information for the safe and efficient operation of your Aspen AX3001/1 Mobile Air Conditioner. Please read these instructions thoroughly before installation and use, and retain them for future reference. Proper use and maintenance will ensure optimal performance and extend the lifespan of your unit.
Awọn Itọsọna Aabo
Pataki: Nigbagbogbo tẹle awọn iṣọra aabo ipilẹ nigba lilo awọn ohun elo itanna lati dinku eewu ina, mọnamọna, ati ipalara si eniyan.
- Rii daju pe ipese agbara ibaamu voltage pato lori awọn kuro ká Rating aami.
- Ma ṣe ṣiṣẹ ẹyọ naa pẹlu okun ti o bajẹ tabi pulọọgi.
- Má ṣe fi ìka tàbí ohun kan sínú ẹnu ọ̀nà afẹ́fẹ́ tàbí ibi tí a ti ń yọ omi kúrò.
- Keep the unit at least 50 cm away from walls or other objects to ensure proper airflow.
- Yọọ kuro nigbagbogbo ṣaaju ṣiṣe mimọ tabi ṣiṣe.
- Ohun elo yii kii ṣe ipinnu fun lilo nipasẹ awọn eniyan (pẹlu awọn ọmọde) pẹlu idinku ti ara, imọlara tabi awọn agbara ọpọlọ, tabi aini iriri ati imọ, ayafi ti wọn ba ti fun wọn ni abojuto tabi itọnisọna nipa lilo ohun elo nipasẹ eniyan ti o ni iduro fun aabo wọn.
- Awọn ọmọde yẹ ki o wa ni abojuto lati rii daju pe wọn ko ṣere pẹlu ohun elo naa.
Package Awọn akoonu
Daju pe gbogbo awọn nkan wa ninu apoti:
- Aspen AX3001/1 Mobile Air Conditioner Unit
- eefi Hose
- Window Sealing Kit (adaptor, flat nozzle)
- Isakoṣo latọna jijin
- Imugbẹ Okun
- Afowoyi Olumulo (iwe-ipamọ yii)
Ṣeto
1. Ipò tí a fi ń gbé ẹ̀rọ náà sí
Place the air conditioner on a flat, stable surface. Ensure there is at least 50 cm of clear space around the unit for proper air circulation. Do not block the air inlets or outlets.

Aworan: Iwaju view of the Aspen AX3001/1 Mobile Air Conditioner. The unit is white with black accents, featuring a control panel on top and a side exhaust port.
2. Eefi Hose fifi sori
- Screw one end of the exhaust hose onto the air outlet on the back of the unit.
- So ohun ti nmu badọgba ohun elo window si opin miiran ti okun eefi.
- Extend the window sealing kit and place it in a partially open window. Secure the window to prevent air leakage.
- Connect the exhaust hose with the adapter to the opening in the window sealing kit. Ensure the hot air is expelled outdoors.

Image: The Aspen AX3001/1 Mobile Air Conditioner shown with the exhaust hose connected, illustrating how hot air is directed away from the unit.
3. Asopọ agbara
Plug the power cord into a grounded electrical outlet. Ensure the outlet meets the power requirements of the unit (240 Volts).
Awọn ilana Iṣiṣẹ
Ibi iwaju alabujutoview
The control panel is located on the top of the unit. It includes buttons for power, mode selection, fan speed, and temperature adjustment. A digital display shows the current settings.

Image: Close-up of the control panel on the top of the Aspen AX3001/1, showing the digital display and various function buttons.
Isẹ ipilẹ
- Titan/Apapa: Tẹ awọn Agbara bọtini lati tan tabi pa kuro.
- Aṣayan Ipo: Tẹ awọn Ipo button to cycle through cooling, fan, and dehumidifier modes.
- Atunṣe iwọn otutu: In cooling mode, use the Up ati Isalẹ awọn ọfa lati ṣeto iwọn otutu ti o fẹ.
- Iyara Olufẹ: Tẹ awọn Iyara Fan button to select low, medium, or high fan speed.
- Iṣẹ Aago: Refer to the remote control section for detailed timer settings.
Isakoṣo latọna jijin
The remote control allows for convenient operation from a distance. It duplicates most functions available on the main control panel.

Image: The remote control for the Aspen AX3001/1 Mobile Air Conditioner, showing buttons for power, mode, fan speed, temperature, and timer functions.
Itoju
Ninu Ajọ Afẹfẹ
The air filter should be cleaned every two weeks or more frequently depending on usage. A dirty filter reduces efficiency and can damage the unit.
- Yọọ air kondisona kuro ninu iṣan agbara.
- Wa ki o yọ àlẹmọ afẹfẹ kuro lati ẹhin tabi ẹgbẹ ti ẹyọkan.
- Wẹ àlẹmọ pẹlu gbona, omi ọṣẹ. Fi omi ṣan daradara.
- Gba àlẹmọ laaye lati gbẹ patapata ṣaaju fifi sori ẹrọ. Ma ṣe fi si imọlẹ orun taara.
Omi Nmu
The unit has a self-evaporating system, but in high humidity conditions, the water tank may fill up. When the tank is full, the unit will stop operating and display an error code (e.g., "FL").
- Yọọ kuro.
- Fi pan tabi atẹ kekere kan si abẹ ibudo omi ni ẹhin isalẹ ti ẹrọ naa.
- Yọ plug sisan kuro lati jẹ ki omi san jade.
- Ni kete ti sisan, rọpo pulọọgi ṣiṣan ni aabo.
Ibi ipamọ
Ti ẹyọ naa ko ba ni lo fun igba pipẹ:
- Sisan gbogbo awọn akojo omi.
- Mọ àlẹmọ afẹfẹ.
- Ṣiṣe ẹyọ naa ni ipo afẹfẹ-nikan fun awọn wakati diẹ lati gbẹ awọn paati inu.
- Yọọ okun agbara naa ki o si ṣa o daradara.
- Bo ẹyọ naa pẹlu apo ike tabi asọ lati daabobo rẹ lati eruku.
- Fipamọ si ibi ti o gbẹ, ti o tutu.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko ni tan-an. | Kò sí agbára; okùn agbára náà ti yọ; ẹ̀rọ ìfọ́mọ́ra náà ti bàjẹ́. | Ṣayẹwo asopọ agbara; atunto Circuit fifọ. |
| Ẹyọ náà kò fi bẹ́ẹ̀ tutù. | Dirty air filter; exhaust hose not properly installed; windows/doors open; room too large. | Clean air filter; ensure exhaust hose is sealed; close windows/doors; consider room size limitations. |
| Unit displays "FL" (Full Water). | Omi omi ti kun. | Fa omi kuro ninu ojò naa gẹgẹbi awọn ilana itọju. |
| Ariwo ariwo nigba isẹ. | Ẹyọ náà kò sí lórí ilẹ̀ títẹ́jú; ìdènà afẹ́fẹ́. | Place on a flat surface; check for obstructions in fan area. |
Ti iṣoro naa ba wa lẹhin igbiyanju awọn iṣeduro wọnyi, jọwọ kan si atilẹyin alabara.
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | AXE3001/1 |
| Brand | Aspen |
| Agbara Itutu | 3.5 kW (approx. 12000 BTU) |
| Orisun agbara | Ina pẹlu okun |
| Voltage | 240 Volts |
| Iwọn Nkan | 32 kg |
| Pataki Awọn ẹya ara ẹrọ | Dehumidifier iṣẹ |
| Ipin Iṣiṣẹ Agbara Igba Igba (SEER) | 10.57 |
| Fọọmù ifosiwewe | Gbigbe |
Atilẹyin ọja ati Support
The Aspen AX3001/1 Mobile Air Conditioner comes with a limited warranty. Please refer to the warranty card included in your packaging for specific terms and conditions. For technical support, spare parts, or warranty claims, please contact your retailer or the manufacturer directly.
Olupese: Aspen
Orukọ awoṣe: AX3001