Testo 0572 1753

Testo 175 T3 Temperature Logger User Manual

Awoṣe: 0572 1753

1. Ọja Ipariview

The Testo 175 T3 temperature logger is designed for precise temperature recording across two channels using external thermocouple probes (Type T or Type K). It is suitable for applications requiring simultaneous temperature monitoring, such as heating system checks or industrial process control. The device features a clear display for current, min/max values, limit violations, and battery life, ensuring high data security with a large memory capacity and long battery life.

Testo 175 T3 Temperature Logger front view

olusin 1: Iwaju view of the Testo 175 T3 Temperature Logger, showing its display and control button.

Testo 175 T3 Temperature Logger placed inside a meat display case, monitoring temperature.

Figure 2: The Testo 175 T3 in use within a meat display case, demonstrating its application in food temperature monitoring.

Testo 175 T3 Temperature Logger mounted inside a refrigerated transport vehicle, monitoring temperature of goods.

Figure 3: The Testo 175 T3 mounted inside a refrigerated transport vehicle, illustrating its use for monitoring temperatures during transit.

2. Awọn akoonu Apoti

Lẹhin ṣiṣi silẹ, rii daju pe gbogbo awọn paati wa:

  • Testo 175 T3 temperature logger (2-channel, with external sensor connections for thermocouple type T and type K)
  • Odi akọmọ
  • Titiipa
  • Awọn batiri (3 x AAA)
  • Ilana odiwọn

Akiyesi: External thermocouple probes and a USB cable for programming/reading are sold separately and are required for full functionality.

3. Eto

  1. Fifi sori batiri: The Testo 175 T3 uses 3 AAA batteries. These are included. Ensure correct polarity when inserting. The logger is designed to retain saved measurement data even if batteries are empty or replaced.
  2. Iṣagbesori: Use the provided wall bracket to securely mount the logger in the desired measurement location.
  3. Asopọ Iwadi: Connect the external thermocouple probes (Type T or Type K, purchased separately) to the two designated connections on the logger. The logger requires at least one external probe to be connected for operation.
  4. Agbara Ibẹrẹ Tan: Once batteries are installed and probes connected, the device will power on. The display will show current readings.

4. Awọn ilana Iṣiṣẹ

4.1. Ifihan Alaye

The clear display provides the following information:

  • Current measuring values for both channels.
  • Minimum (Min) and Maximum (Max) recorded values.
  • Set limit values.
  • Indications of limit value violations.
  • Remaining battery life.

4.2. Gedu data

The Testo 175 T3 automatically logs data at a user-defined measuring rate, ranging from 10 seconds to 24 hours. It has a memory capacity of up to 1 million readings.

4.3. Programming and Data Analysis

To program the data logger and analyze measurement data, a USB cable (optional) and software are required. Three software versions are available:

  • ComSoft Basic: Free download for fast programming and easy data analysis.
  • ComSoft Professional: Optional purchase for more detailed analysis possibilities.
  • ComSoft CFR 21 Part 11: Optional purchase, suitable for pharmaceutical sector requirements (CFR 21 Part 11).
Testo 175 T3 connected to a laptop via USB cable, showing data analysis software on screen.

Figure 4: The Testo 175 T3 connected to a laptop for programming and data analysis using ComSoft software.

5. Itọju

  • Ninu: The device has an IP65 protection class, offering protection against dust ingress and water spray/jets. For cleaning, wipe the exterior with a damp asọ. Ma ṣe lo abrasive ose tabi epo.
  • Rirọpo Batiri: When the battery indicator shows low power, replace the 3 AAA batteries. Ensure the device is powered off before replacement. Data security is maintained during battery changes.
  • Iṣatunṣe: Regular calibration is recommended to ensure continued accuracy. Refer to the calibration protocol included with your device for details.

6. Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹrọ ti ko ni agbara lori.Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ.Replace batteries (3 x AAA) and ensure correct polarity.
No temperature readings displayed.No external probe connected or probe faulty.Connect at least one external thermocouple probe. Check probe connection and integrity.
Cannot connect to PC for data transfer.USB cable not connected, driver issue, or software not running.Ensure USB cable is securely connected. Install necessary drivers. Launch ComSoft software.
Awọn kika ti ko pe.Probe damage or calibration required.Inspect probes for damage. Consider professional calibration.

7. Imọ ni pato

ParamitaIye
Temperature - TC Type K (NiCr-Ni)
Iwọn iwọn-50 si +1000 °C
Yiye±0.5 °C (-50 to +70 °C), ±0.7 % of mv (+70.1 to +1000 °C)
Ipinnu0.1 °C
Temperature - TC Type T (Cu-CuNi)
Iwọn iwọn-50 si +400 °C
Yiye±0.5 °C (-50 to +70 °C), ±0.7 % of mv (70.1 to +1000 °C)
Ipinnu0.1 °C
Gbogbogbo Imọ Data
Ibi ipamọ otutu-20 si +55 °C
Awọn iwọn89 x 53 x 27 mm
Awọn iwọn otutu ti nṣiṣẹ-20 si +55 °C
Idaabobo kilasiIP65
Awọn ikanni2 ita
Wiwọn oṣuwọn10 s - 24 h
Iru batiri3 x AIMn type AAA or Energizer
Aye batiri3 years at 15 min. meas. rate
Iranti1,000,000 awọn iye iwọn
Iwọn Nkan130 g
Ohun eloPolycarbonate (PC)
Iru ifihanLCD
AsopọmọraUSB (with optional cable)

8. atilẹyin ọja Information

The Testo 175 T3 Temperature Logger comes with a 2-odun atilẹyin ọja. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the documentation provided with your product or contact Testo customer support.

9. Atilẹyin ati Olubasọrọ

For technical support, software downloads (ComSoft Basic), or inquiries regarding optional accessories (probes, USB cable, ComSoft Professional/CFR 21 Part 11), please visit the official Testo website or contact your local Testo distributor. Contact information can typically be found on the Testo official webojula.

Awọn iwe aṣẹ ti o jọmọ - 0572 1753

Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Àwọn Olùkọ Ìdátà 160 Lórí Ayélujára
Ìwé ìtọ́ni olùlò fún àwọn olùtọ́jú ìwádìí lórí ayélujára Testo 160, tí ó bo ìṣètò, iṣẹ́, ìtọ́jú, àti àwọn ìlànà ìmọ̀-ẹ̀rọ fún ìwọ̀n otútù, ọriniinitutu, adùn, àti UV.
Ṣaajuview testo Saveris 2 WiFi Data Logger System Instruction Manual
Comprehensive instruction manual for the testo Saveris 2 WiFi data logger system, covering setup, configuration, operation, safety, technical data, and troubleshooting.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Àwọn Olùkọ Ìdátà 164 Lórí Ayélujára
User manual for the Testo 164 series of online data loggers (T1, H1, DC) and the GW Gateway. Learn about system setup, commissioning, operation, maintenance, troubleshooting, and technical specifications for accurate environmental monitoring.
Ṣaajuview Àwọn Olùkọsílẹ̀ Dátà Testo 175: Ìwé Ìtọ́ni
Ìwé ìtọ́ni tó péye fún àwọn olùtọ́jú ìwádìí ìwádìí Testo 175, tó bo iṣẹ́ wọn, àwọn ìlànà ìmọ̀ ẹ̀rọ, àti ìtọ́jú wọn fún ìtọ́jú iwọ̀n otútù àti ọriniinitutu.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Onígbọ̀wọ́ Dátà Testo 176 - Ìwọ̀n otútù, Ọrinrin, Àbójútó Ìfúnpá
Ìwé ìtọ́ni tó péye fún àwọn olùtọ́jú ìwádìí ìwádìí Testo 176, títí kan àwọn àpẹẹrẹ T1, T2, T3, T4, H1, H2, àti P1. Kọ́ nípa lílo ọjà, àwọn ìlànà ìmọ̀ ẹ̀rọ, ìṣètò, ìṣiṣẹ́, ìtọ́jú, àti ìṣòro fún ìgbóná ara tó péye, ọriniinitutu, àti ìṣàyẹ̀wò titẹ.
Ṣaajuview testo 176 データロガー 取扱説明書
testo 176.176 P1モデルの機能、技術仕様、初期操作、ディスプレイ表示、GOボタン機能、センサ接続、プログラミング、メンテナンス、トラブルシューティング、アクセサリ、保証に関する詳細情報を提供します。testo ComSoft ソフトウェアとの連携についても解説。