Ọrọ Iṣaaju
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Alaye Aabo
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Daju pe voltage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Rí i dájú pé ilẹ̀ tó yẹ lẹ̀ níbi tó bá yẹ.
Ọja Pariview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing and internal components.
Eto ati fifi sori
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Ge asopọ agbara: Ensure all power to the circuit is completely disconnected before beginning installation.
- Iṣagbesori: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Asopọmọra: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

olusin 3: Isalẹ view of the relay, showing the through-hole connector pins for wiring connections.
- Voltage Ijeri: Jerisi pe ipese voltage for the coil matches the relay's specified voltage ti 110-120V AC, 50/60Hz.

olusin 4: Isunmọ view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

olusin 5: Apa view of the relay, displaying detailed electrical ratings and certifications.
- Ṣayẹwo Ipari: Before restoring power, double-check all connections for security and correctness.
Awọn ilana Iṣiṣẹ
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage ibiti o fun gbẹkẹle isẹ.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Itoju
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Ayewo wiwo: Periodically check the relay for any signs of physical damage, discoloration, or loose connections.
- Ninu: Tí ó bá pọndandan, fi aṣọ gbígbẹ tí ó rọra fọ ìta relay náà pẹ̀lú pẹ̀lẹ́pẹ̀lẹ́. Má ṣe lo àwọn ohun èlò ìfọ́ tàbí àwọn ohun èlò ìfọ́mọ́ra.
- Àyẹ̀wò Olùbáṣepọ̀: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Awọn ipo Ayika: Rii daju pe agbegbe iṣẹ wa laarin iwọn otutu ti a sọ ati awọn sakani ọriniinitutu lati ṣe idiwọ ikuna ti tọjọ.
Laasigbotitusita
If the relay is not functioning as expected, consider the following common issues:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Awọn pato
| Paramita | Iye |
|---|---|
| Nọmba awoṣe | RH2B-UL-AC110-120V |
| Brand | Idec |
| Coil Voltage | 110-120V AC |
| Igbohunsafẹfẹ | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| Horsepower Rating | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Iṣagbesori Iru | DIN Rail Oke |
| Asopọmọra Iru | Nipasẹ Iho |
| Ipo Isẹ | Laifọwọyi |
| Iwọn Nkan | 0.01 iwon |
| Olupese | Idec |
Atilẹyin ọja ati Support
For warranty information and technical support, please contact Idec directly through their official webojula tabi onibara iṣẹ awọn ikanni. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.
Idec Official Webojula: us.idec.com