1. Ifihan
This manual provides essential instructions for the installation, operation, and maintenance of your APC Back-UPS BX600C-IN. This Uninterruptible Power Supply (UPS) system is designed to provide power backup and surge protection for home office equipment, desktop PCs, and other home electronics, ensuring continuous operation during power outages and protecting against voltage awọn iyipada.
2. Alaye Aabo pataki
Please read and understand these instructions carefully before installing or operating the UPS. Failure to follow these instructions can result in serious injury or equipment damage.
⚠ IKILO: EWU TI mọnamọna itanna
- Do not remove the cover. Hazardous live parts inside this UPS are present even when the unit is disconnected from the mains.
- Tọkasi iṣẹ si oṣiṣẹ ti o peye nikan.
- Rii daju didasilẹ to dara ti iṣan itanna.
- Do not connect non-computer related items like hair dryers, vacuum cleaners, or other high-power appliances to the battery backup outlets.
Always disconnect the UPS from the power source before performing any maintenance or service.
3. Package Awọn akoonu
The APC Back-UPS BX600C-IN package should contain the following items:
- APC Back-UPS BX600C-IN Unit
- Afowoyi Olumulo (iwe-ipamọ yii)
Inspect the package upon receipt. Notify the carrier and dealer if there is any damage.
4. Ọja Ipariview
4.1. Key Awọn ẹya ara ẹrọ
- Apẹrẹ Iwapọ: Line Interactive UPS with a load capacity of 360 Watts / 600VA.
- Battery Backup & Surge Protection: Three 6A, 2/3 Pin output Indian Power Sockets provide battery backup and surge protection.
- Aifọwọyi Voltage Ilana (AVR): Corrects incoming voltage fluctuations within a wide range of 145-290V.
- Batiri: Equipped with a 1x7.2Ah battery, offering 20-75 minutes of backup time depending on the load.
- Ibamu pẹlu Generator: Designed to work with generators.
- Low Power Load Compatibility: Suitable for devices like Wi-Fi routers and DSL modems.
- Cold Start Capability: Allows the UPS to power on using only battery power.
- Gbigba agbara yiyara: Recharges the battery in 4-6 hours.
- Isẹ idakẹjẹ: Maintains quiet operation during transfer from mains to generator power.
4.2. Igbimọ iwaju

Nọmba 1: Iwaju view of the APC Back-UPS BX600C-IN. This image displays the power button, battery indicator, and surge protection indicator on the front panel.
- Bọtini agbara: Controls the UPS power on/off.
- Atọka Batiri: Shows battery status (charging, on battery, low battery).
- Atọka Idaabobo Iṣẹ abẹ: Ṣe itanna nigbati aabo iṣẹ abẹ ṣiṣẹ.
4.3. Rule nronu

Nọmba 2: Ẹyìn view of the APC Back-UPS BX600C-IN. This image shows the three battery backup and surge protected outlets, the input power cord, and ventilation grilles.
- Àwọn ibi ìtajà tí a dáàbò bo láti inú batiri àti àtìlẹ́yìn: Three 6A, 2/3 Pin Indian standard outlets for connecting critical equipment. These outlets provide power during outagati aabo lodi si awọn igbi omi.
- Okun Agbara Ti nwọle: Connects the UPS to the utility power outlet.
- Awọn Grilles Afẹfẹ: Ensure proper airflow for cooling.
5. Awọn ilana iṣeto
- Ibi: Place the UPS in a cool, dry location, away from direct sunlight, excessive heat, or moisture. Ensure adequate ventilation around the unit.
- Gbigba agbara Batiri akọkọ: Connect the UPS to a grounded wall outlet using the attached power cord. Allow the unit to charge for at least 8 hours before connecting any equipment. This ensures optimal battery runtime.
- Ohun elo Sopọ:
- Connect your computer, monitor, and other critical devices (e.g., Wi-Fi router, modem) to the Afẹyinti Batiri & Awọn ile-iṣẹ Idabobo Agbara on the rear of the UPS.
- Do not overload the UPS. The total wattage of connected equipment should not exceed 360 Watts.
- Agbara Tan: Press the power button on the front panel to turn on the UPS. The power indicator will illuminate.
Ensure all connections are secure before powering on your devices.
6. Awọn ilana Iṣiṣẹ
6.1. Turning the UPS On/Off
- Lati Tan: Press and hold the power button on the front panel until a beep is heard. The power indicator will light up.
- Lati Pa: Press and hold the power button until a beep is heard and the power indicator turns off.
6.2. Understanding Indicators and Alarms
| Indicator/Alarm | Apejuwe |
|---|---|
| Power Indicator (Green LED) On | UPS is providing power to connected equipment. |
| Power Indicator (Green LED) Flashing | UPS n ṣiṣẹ lori agbara batiri. |
| Audible Alarm (Beeping) | Indicates the UPS is operating on battery power. Beeps more frequently as battery charge depletes. |
| Continuous Alarm / Red Indicator | Indicates low battery, overload, or a fault condition. |
| Surge Protection Indicator On | Surge protection is active and functioning. |
6.3. Aifọwọyi VoltagIlana (AVR)
UPS naa n ṣe atunṣe vol kekere laifọwọyitage fluctuations (sags and surges) without switching to battery power, extending battery life. If the voltage fluctuation is too severe or prolonged, the UPS will switch to battery power.
6.4. Cold Start Function
The cold start feature allows you to power on the UPS and connected equipment using only battery power, even if there is no utility power available. To perform a cold start, ensure the UPS is off, then press and hold the power button until the unit powers on.
7. Itọju
7.1. Battery Care and Replacement
The UPS contains a sealed, maintenance-free lead-acid battery. The battery is designed for a service life of 3-5 years under normal operating conditions. Factors like frequent power outages, high temperatures, and deep discharges can reduce battery life.
- Iru Batiri: The UPS uses one 12V battery.
- Rọpo: Battery replacement should only be performed by qualified service personnel. Refer to the safety information before attempting any service.
- Idasonu: Batteries must be recycled properly. Contact your local recycling center or APC for disposal information.
7.2. Ninu
Máa fọ ìta UPS náà lẹ́ẹ̀kọ̀ọ̀kan pẹ̀lú aṣọ gbígbẹ tó rọ. Má ṣe lo ohun èlò ìfọmọ́ omi tàbí aerosol. Rí i dájú pé àwọn ihò afẹ́fẹ́ kò ní eruku àti èérí.
8. Laasigbotitusita
This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact APC customer support.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| UPS ko ni tan. |
|
|
| UPS beeps frequently or continuously. |
|
|
| Akoko afẹyinti kukuru. |
|
|
| UPS makes chattering noises. |
|
|
9. Imọ ni pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Awoṣe | BX600C-IN |
| Agbara | 600VA / 360W |
| Iṣagbewọle Voltage Ibiti | 145-290V AC |
| O wujade Voltage | 230V AC |
| Igbohunsafẹfẹ Ijade | 47 - 63 Hz (Sync to mains) |
| Akoko Gbigbe | 10 ms aṣoju, 12 ms ti o pọju |
| Batiri Iru | 1 x 12V, 7.2Ah Sealed Lead-Acid |
| Aṣoju gbigba agbara Time | 4-6 wakati |
| Backup Time (Typical) | 20 - 75 minutes (load dependent) |
| Awọn iÿë | 3 x 6A, 2/3 Pin Indian Sockets (Battery Backup & Surge Protected) |
| Awọn iwọn (H x W x D) | 23.7 x 10.7 x 21.8 cm |
| Iwọn | 4.69 kg |
| Awọn iwọn otutu ti nṣiṣẹ | 0°C si 40°C (32°F si 104°F) |
10. Atilẹyin ọja ati Support
APC provides a comprehensive warranty for this product.
- Akoko atilẹyin ọja: The APC Back-UPS BX600C-IN comes with a 2-odun atilẹyin ọja covering parts and labor, including the battery.
- Olubasọrọ Support: For technical assistance, warranty claims, or service inquiries, please contact APC customer support. Refer to the official APC website or your purchase documentation for the most current contact information in your region.
- Olupese: SCHNEIDER ELECTRIC IT BUSINESS INDIA PRIVATE LIMITED.
Jọwọ ṣe idaduro ẹri rira rẹ fun awọn idi atilẹyin ọja.