APC BX600C-IN

Ìwé Ìtọ́sọ́nà Olùlò Ẹ̀rọ UPS APC BX600C-IN 600VA / 360W

Model: BX600C-IN

1. Ifihan

This manual provides essential instructions for the installation, operation, and maintenance of your APC Back-UPS BX600C-IN. This Uninterruptible Power Supply (UPS) system is designed to provide power backup and surge protection for home office equipment, desktop PCs, and other home electronics, ensuring continuous operation during power outages and protecting against voltage awọn iyipada.

2. Alaye Aabo pataki

Please read and understand these instructions carefully before installing or operating the UPS. Failure to follow these instructions can result in serious injury or equipment damage.

⚠ IKILO: EWU TI mọnamọna itanna

  • Do not remove the cover. Hazardous live parts inside this UPS are present even when the unit is disconnected from the mains.
  • Tọkasi iṣẹ si oṣiṣẹ ti o peye nikan.
  • Rii daju didasilẹ to dara ti iṣan itanna.
  • Do not connect non-computer related items like hair dryers, vacuum cleaners, or other high-power appliances to the battery backup outlets.

Always disconnect the UPS from the power source before performing any maintenance or service.

3. Package Awọn akoonu

The APC Back-UPS BX600C-IN package should contain the following items:

Inspect the package upon receipt. Notify the carrier and dealer if there is any damage.

4. Ọja Ipariview

4.1. Key Awọn ẹya ara ẹrọ

4.2. Igbimọ iwaju

Iwaju view of APC Back-UPS BX600C-IN showing power button and indicators

Nọmba 1: Iwaju view of the APC Back-UPS BX600C-IN. This image displays the power button, battery indicator, and surge protection indicator on the front panel.

4.3. Rule nronu

Ẹyìn view of APC Back-UPS BX600C-IN showing power outlets and input

Nọmba 2: Ẹyìn view of the APC Back-UPS BX600C-IN. This image shows the three battery backup and surge protected outlets, the input power cord, and ventilation grilles.

5. Awọn ilana iṣeto

  1. Ibi: Place the UPS in a cool, dry location, away from direct sunlight, excessive heat, or moisture. Ensure adequate ventilation around the unit.
  2. Gbigba agbara Batiri akọkọ: Connect the UPS to a grounded wall outlet using the attached power cord. Allow the unit to charge for at least 8 hours before connecting any equipment. This ensures optimal battery runtime.
  3. Ohun elo Sopọ:
    • Connect your computer, monitor, and other critical devices (e.g., Wi-Fi router, modem) to the Afẹyinti Batiri & Awọn ile-iṣẹ Idabobo Agbara on the rear of the UPS.
    • Do not overload the UPS. The total wattage of connected equipment should not exceed 360 Watts.
  4. Agbara Tan: Press the power button on the front panel to turn on the UPS. The power indicator will illuminate.

Ensure all connections are secure before powering on your devices.

6. Awọn ilana Iṣiṣẹ

6.1. Turning the UPS On/Off

6.2. Understanding Indicators and Alarms

UPS Status Indicators
Indicator/AlarmApejuwe
Power Indicator (Green LED) OnUPS is providing power to connected equipment.
Power Indicator (Green LED) FlashingUPS n ṣiṣẹ lori agbara batiri.
Audible Alarm (Beeping)Indicates the UPS is operating on battery power. Beeps more frequently as battery charge depletes.
Continuous Alarm / Red IndicatorIndicates low battery, overload, or a fault condition.
Surge Protection Indicator OnSurge protection is active and functioning.

6.3. Aifọwọyi VoltagIlana (AVR)

UPS naa n ṣe atunṣe vol kekere laifọwọyitage fluctuations (sags and surges) without switching to battery power, extending battery life. If the voltage fluctuation is too severe or prolonged, the UPS will switch to battery power.

6.4. Cold Start Function

The cold start feature allows you to power on the UPS and connected equipment using only battery power, even if there is no utility power available. To perform a cold start, ensure the UPS is off, then press and hold the power button until the unit powers on.

7. Itọju

7.1. Battery Care and Replacement

The UPS contains a sealed, maintenance-free lead-acid battery. The battery is designed for a service life of 3-5 years under normal operating conditions. Factors like frequent power outages, high temperatures, and deep discharges can reduce battery life.

7.2. Ninu

Máa fọ ìta UPS náà lẹ́ẹ̀kọ̀ọ̀kan pẹ̀lú aṣọ gbígbẹ tó rọ. Má ṣe lo ohun èlò ìfọmọ́ omi tàbí aerosol. Rí i dájú pé àwọn ihò afẹ́fẹ́ kò ní eruku àti èérí.

8. Laasigbotitusita

This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact APC customer support.

Laasigbotitusita Itọsọna
IsoroOwun to le FaOjutu
UPS ko ni tan.
  • Not connected to utility power.
  • Batiri ko gba agbara.
  • Batiri ti ko tọ.
  • Ensure the UPS is securely plugged into a grounded wall outlet.
  • Allow the UPS to charge for at least 8 hours.
  • Contact APC support for battery replacement if necessary.
UPS beeps frequently or continuously.
  • Operating on battery power.
  • Batiri kekere.
  • Apọju ipo.
  • Check utility power. Save work and shut down equipment if power outage persists.
  • Allow battery to recharge.
  • Disconnect non-essential equipment from battery backup outlets. Reduce total load to below 360W.
Akoko afẹyinti kukuru.
  • Batiri ko gba agbara ni kikun.
  • Batiri ti o sunmọ opin aye.
  • Apọju.
  • Ensure UPS is fully charged before use.
  • Consider battery replacement by qualified personnel.
  • Dín ẹrù tí a so pọ̀ kù.
UPS makes chattering noises.
  • Fluctuating input power (AVR engaging).
  • Loose internal components (rare).
  • This is normal operation for AVR.
  • If persistent and loud, contact APC support.

9. Imọ ni pato

APC Back-UPS BX600C-IN Specifications
Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
AwoṣeBX600C-IN
Agbara600VA / 360W
Iṣagbewọle Voltage Ibiti145-290V AC
O wujade Voltage230V AC
Igbohunsafẹfẹ Ijade47 - 63 Hz (Sync to mains)
Akoko Gbigbe10 ms aṣoju, 12 ms ti o pọju
Batiri Iru1 x 12V, 7.2Ah Sealed Lead-Acid
Aṣoju gbigba agbara Time4-6 wakati
Backup Time (Typical)20 - 75 minutes (load dependent)
Awọn iÿë3 x 6A, 2/3 Pin Indian Sockets (Battery Backup & Surge Protected)
Awọn iwọn (H x W x D)23.7 x 10.7 x 21.8 cm
Iwọn4.69 kg
Awọn iwọn otutu ti nṣiṣẹ0°C si 40°C (32°F si 104°F)

10. Atilẹyin ọja ati Support

APC provides a comprehensive warranty for this product.

Jọwọ ṣe idaduro ẹri rira rẹ fun awọn idi atilẹyin ọja.

Awọn iwe aṣẹ ti o jọmọ - BX600C-IN

Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Àtìlẹ́yìn APC: Àwọn Àwòrán 250-1250
Ìwé ìtọ́ni tó péye fún àwọn oníbàárà APC Back-UPS tí kò lè dáwọ́ dúró 250, 400, 450, 600, 900, àti 1250. Ó ní ààbò, ìfisílẹ̀, ìṣiṣẹ́, ìṣòro àti àwọn ìlànà pàtó.
Ṣaajuview APC Back-UPS ES 400/550/700 Itọsọna olumulo ati Awọn pato
Itọsọna olumulo fun APC Back-UPS ES 400, 550, ati 700 jara awọn ipese agbara ti ko ni idilọwọ (UPS), iṣeto ibora, asopọ, ṣiṣe, laasigbotitusita, awọn pato, ati atilẹyin ọja.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Àtìlẹ́yìn APC BN600G
Ìwé ìtọ́ni fún APC Back-UPS BN600G Uninterruptible Power Supply (UPS), èyí tí ó ń pèsè ìwífún nípa ààbò, àwọn ìlànà pàtó, fífi sori ẹ̀rọ, iṣẹ́, ṣíṣe àtúnṣe, àti àwọn àlàyé ìdánilójú.
Ṣaajuview Ìtọ́sọ́nà Ìfisílẹ̀ àti Ìṣiṣẹ́ APC Back-UPS Pro 1200/1500 230V
Ìtọ́sọ́nà tó péye fún fífi sori ẹrọ àti ṣíṣiṣẹ́ APC Back-UPS Pro 1200/1500 230V. Ó ní ààbò, ìṣètò, fífi sọ́fítíwèlì sí, ìṣiṣẹ́, ìṣòro, àwọn ìlànà pàtó, àti àtìlẹ́yìn.
Ṣaajuview APC Back-UPS Pro 900 Installation and Operation Guide
This guide provides instructions for installing and operating the APC Back-UPS Pro 900, including setup, software installation, connection of equipment, operational features like power saving and display modes, troubleshooting, and specifications.
Ṣaajuview APC Back-UPS BR1000G-IN / BR1500G-IN: Ìwé Ìtọ́sọ́nà fún Fífi sori ẹrọ àti Ìṣiṣẹ́
Ìtọ́sọ́nà pípéye fún fífi APC Back-UPS BR1000G-IN àti BR1500G-IN Uninterruptible Power Supply (UPS) sí àti ṣíṣiṣẹ́, èyí tí ó ní àwọn ìlànà pàtó, àwọn ìsopọ̀, àwọn ẹ̀yà ara, ìṣòro, àti iṣẹ́.