1. Ifihan
This manual provides essential instructions for the safe and effective operation, setup, and maintenance of the Fluke 123/003 Industrial ScopeMeter. The Fluke 123/003 is a handheld electrical test device combining a two-channel digital oscilloscope with a true RMS digital multimeter, designed for industrial and commercial applications.
2. Ohun ti o wa ninu Apoti
Daju pe gbogbo awọn nkan ti a ṣe akojọ rẹ si isalẹ wa ninu package rẹ:
- Fluke ScopeMeter series 120 handheld oscilloscope/multimeter
- Set of test leads with mini clips and alligator clips
- BNC-to-banana adapter
- Rechargeable NiMH battery pack (installed)
- AC adapter/battery charger
- Itọsọna olumulo (iwe yii)
- Optional: SCC120 kit (if purchased with kit), which includes:
- FlukeView software
- RS-232 / USB ohun ti nmu badọgba
- Lile rù nla

Figure 1: Fluke 123/003 ScopeMeter with its standard accessories, including test leads, BNC-to-banana adapter, battery charger, and the main unit.
3. Ọja Ipariview
The Fluke 123/003 ScopeMeter is a versatile tool for electrical testing, combining the functionalities of a digital oscilloscope and a digital multimeter. It is designed for accurate measurement and analysis of electrical signals in various industrial settings.
Awọn ẹya pataki:
- Iṣẹ ṣiṣe meji: Combines a two-channel digital oscilloscope and a true RMS digital multimeter.
- Awọn Agbara Oscilloscope: Akoko gidi sample rate of 25MS/s, record length of 512 points per channel, automatic and cursor measurement parameters, edge and video triggers.
- Àwọn Iṣẹ́ Multimeter: Awọn iwọn AC ati DC voltage (up to 1,250V), resistance (up to 50MΩ), capacitance (up to 500µF), frequency (up to 50MHz), and duty cycle (2% to 98%).
- RMS otitọ: Provides accurate readings for both linear and non-linear loads.
- Ifihan: 2.83" monochrome LCD with 240 x 240 pixels resolution and backlight for low-light conditions.
- Ibi ipamọ data: Internal memory for storing up to 10 setups and screenshots.
- TrendPlot: Chart recorder function for graphing minimum and maximum values over time.
- Asopọmọra: Optically isolated RS-232 interface for data transfer to a PC or printer.
- Awọn Ilana Abo: Meets EN 61010-1:2001, ANSI/ISA S82.02.01, CAN/CSA C22.2 61010-1-04, and UL 61010-1-04 safety standards; CAT III 600V rated; CE marking.
4. Eto
4.1. Agbara ẹrọ naa
The Fluke 123/003 operates on a rechargeable NiMH battery pack (pre-installed) or via the included AC adapter/charger.
- Iṣẹ Batiri: Ensure the NiMH battery pack is charged. The device will automatically shut down after 30 minutes of non-use to conserve battery life. A low-battery indicator will signal when recharging is needed.
- Agbara AC: Connect the AC adapter/charger to the device and a standard 120V, 60Hz power outlet for continuous operation and battery charging.
4.2. Connecting Test Leads and Probes
Connect the appropriate test leads or probes to the input channels of the ScopeMeter based on your measurement requirements. Use the BNC-to-banana adapter as needed for specific connections.
- Insert the test leads into the input jacks.
- Ensure connections are secure before taking any measurements.
- For external triggering, an optical port is available for attaching a Fluke ITP120 probe (sold separately).
5. Awọn ilana Iṣiṣẹ
The Fluke 123/003 features an intuitive interface with drop-down menus for easy navigation. Refer to the on-screen prompts and the full user manual for detailed operational procedures.
5.1. Iṣẹ Oscilloscope
- Waveform Acquisition: The oscilloscope acquires waveforms with a real-time sample rate of 25MS/s and a record length of 512 points per channel.
- Nfa: Utilize advanced automatic triggering, which recognizes signal patterns and optimizes triggering, timebase, and amplitude settings. Edge and video triggers are available for isolating specific signals.
- Awọn iwọn: Use automatic and cursor measurement parameters for in-depth waveform analysis.
5.2. Multimeter Išė
- Awọn ọna ipo: Select between manual ranging (user selects operating range) and auto ranging (device automatically selects appropriate range).
- Iṣẹ ibatan: Set a measurement as a reference and display subsequent measurements as deviations.
- Touch-Hold Mode: Captures and holds a stable reading on the display.
- Data-Hold Function: Freezes a reading on the display for documentation.
- Continuity and Diode Check: Use these functions to verify circuit conductivity and diode functionality.
5.3. Data Management
- Storing Data: Store up to 10 setups and screen shots in the internal memory.
- TrendPlot: Use the TrendPlot chart recorder to graph minimum and maximum values from both oscilloscope and multimeter functions over time. The recorder can be programmed for various time scales.
- PC/Printer Connection: Use the optically isolated RS-232 interface to connect to a compatible printer for direct data printing or to a PC for data storage and analysis (requires FlukeView software and RS-232/USB adapter, typically part of the SCC120 kit).
6. Itọju
6.1. Itọju batiri
To ensure optimal performance and longevity of the NiMH battery pack:
- Recharge the battery when the low-battery indicator appears.
- Use only the provided AC adapter/battery charger.
- The device features an automatic shutdown after 30 minutes of inactivity to preserve battery life.
6.2. Ninu
Nu ẹrọ ita ita pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
6.3. Iṣatunṣe
Regular calibration ensures the accuracy of your ScopeMeter. Refer to the full user manual for recommended calibration intervals and procedures. An example of a calibration certificate is shown below.

Olusin 2: Example of a Certificate of Calibration, demonstrating the importance of regular calibration for measurement accuracy.
7. Laasigbotitusita
For common operational issues, consult the comprehensive troubleshooting section in the full user manual. If you encounter problems not covered in the manual or require further assistance, please contact Fluke customer support.
Awọn imọran Laasigbotitusita Gbogbogbo:
- Ko si Agbara: Ensure the battery is charged or the AC adapter is properly connected.
- Awọn kika ti ko tọ: Verify test lead connections, ensure correct measurement mode is selected, and check for proper calibration.
- Awọn oran Ifihan: Check backlight settings. If the display remains blank or faulty, contact support.
8. Awọn pato
The following table outlines the key technical specifications for the Fluke 123/003 Industrial ScopeMeter:
| Sipesifikesonu | Iye |
|---|---|
| Ifihan | 2.83" monochrome LCD (240 x 240 pixels) |
| Bandiwidi | 20MHz |
| Awọn ikanni Input | Meji |
| Akoko gidi Sample Oṣuwọn | 25MS/s |
| Ipari Gbigbasilẹ | 512 points per channel |
| O pọju DC Voltage Idiwon | 1,250V |
| Maximum Resistance Measured | 50MΩ |
| Maximum Capacitance Measured | 500µF |
| Maximum Frequency Measured | 50MHz |
| Fifi sori Rating | CAT III, 600V |
| Awọn Ilana Abo Met | EN 61010-1:2001, ANSI/ISA S82.02.01, CAN/CSA C22.2 61010-1-04, UL 61010-1-04; CE marking |
| Orisun agbara | Rechargeable NiMH battery pack or 120V, 60Hz AC adapter/charger |
| Iwọn Nkan | 3 iwon |
Note: H is height, W is width, D is depth. These dimensions are not explicitly provided for the 123/003 model in the source data.
9. Alaye Aabo
Always adhere to safety precautions when operating electrical test equipment. The Fluke 123/003 ScopeMeter is designed and tested to meet stringent safety standards.
- Ibamu: The unit meets European Standard (EN) 61010-1:2001, American National Standards Institute and International Society of Automation (ANSI/ISA) S82.02.01, CAN/CSA (Canadian Standards Association) C22.2 61010-1-04, and UL (Underwriters Laboratories) 61010-1-04 safety standards. It also carries CE (European Conformity) marking.
- Ẹka fifi sori ẹrọ: Rated for CAT III installations to 600V. This covers equipment in fixed installations, such as switches in the fixed installation and some industrial equipment that is permanently connected to the fixed installation.
- Aabo gbogbogbo:
- Ma ṣe lo ẹrọ naa ti o ba han pe o bajẹ tabi ti n ṣiṣẹ laiṣe deede.
- Ensure all test leads and probes are in good condition and properly connected.
- Ṣe akiyesi gbogbo awọn koodu aabo agbegbe ati ti orilẹ-ede.
- Refer to the complete safety instructions in the full user manual before operation.
10. Atilẹyin ọja ati Support
Fluke Corporation manufactures electrical testing tools and software for industrial and commercial applications. For detailed warranty information, including terms and conditions, please refer to the warranty card included with your product or visit the official Fluke webojula.
For technical support, service, or to order replacement parts, contact Fluke customer service. Contact information can typically be found in the full user manual or on the Fluke Corporation webojula.
Olupese: Fluke Corporation, headquartered in Everett, WA, USA.