Simplex 4099 9004

Simplex 4099-9004 Single Action Addressable Manual Pull Station User Manual

Awoṣe: 4099-9004

1. Ifihan

This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4099-9004 Single Action Addressable Manual Pull Station. This device is designed to initiate a fire alarm signal upon manual activation, integrating seamlessly into compatible fire alarm control panels.

The Simplex 4099-9004 is a robust and reliable component of a comprehensive fire detection system, ensuring prompt notification in emergency situations. It features a single-action pull mechanism for straightforward activation.

2. Alaye Aabo

IKILO: Installation and servicing of this device must be performed by qualified personnel only, in accordance with all local and national electrical codes, fire codes, and the manufacturer's instructions. Failure to do so may result in property damage, serious injury, or death.

3. Eto ati fifi sori

The Simplex 4099-9004 pull station is designed for indoor surface or flush mounting. Proper installation is critical for reliable operation.

3.1 Unboxing ati ayewo

Upon receiving the product, carefully inspect the packaging and the device for any signs of damage. The product packaging includes key identification information such as the Product ID (PID), Description, Part Number, and Serial Number.

Simplex 4099-9004 Pull Station product box with label showing PID, description, part number, and serial number.

Figure 1: Packaging for the Simplex 4099-9004 Pull Station, displaying product identification details including PID: 4099-9004, Description: STATION-LED, SA ADDR, Part No. 06501205, and Serial No. 0650120516047/997.

3.2 Iṣagbesori

Mount the pull station at the height specified by local codes (typically 42-48 inches from the floor to the operating handle). Ensure the mounting surface is flat and secure. Use appropriate screws and anchors for the wall material.

3.3 Onirin

Connect the pull station to the fire alarm control panel's Signaling Line Circuit (SLC) using appropriate gauge wire as specified by the system's design and local codes. The 4099-9004 is an addressable device, meaning it communicates digitally with the control panel. Refer to the specific wiring diagram provided with your fire alarm control panel for detailed connection instructions. Ensure proper polarity and secure all connections within the terminal block.

4. Awọn ilana Iṣiṣẹ

The Simplex 4099-9004 is a single-action pull station. To activate the fire alarm:

  1. Locate the manual pull station.
  2. Firmly grasp the handle and pull it down.
  3. The handle will latch in the down position, indicating activation.
  4. The pull station will send a signal to the fire alarm control panel, initiating the alarm sequence (e.g., sounding horns, flashing strobes, notifying monitoring station).

To reset the pull station after activation, insert the appropriate key into the keyhole and turn it to release the handle. The handle will return to its original position. Remove the key.

Video 1: A demonstration of the Simplex 4099-9004 pull station, showcasing its design and how it appears from various angles. This video provides a visual overview of the product's physical characteristics.

5. Itọju

Regular maintenance ensures the longevity and reliability of your Simplex 4099-9004 pull station.

5.1 baraku Cleaning

Clean the exterior of the pull station periodically with a soft, damp asọ. Ma ṣe lo awọn olutọpa abrasive tabi awọn olomi, nitori iwọnyi le ba ipari tabi awọn paati inu jẹ.

5.2 Igbeyewo iṣẹ

Functional testing should be performed regularly as required by local fire codes and NFPA standards (e.g., annually, semi-annually). During testing, activate the pull station to ensure it sends an alarm signal to the control panel. Reset the device after testing. All tests should be conducted by trained and authorized personnel.

6. Laasigbotitusita

This section addresses common issues you might encounter with the Simplex 4099-9004 pull station. For complex issues, contact a qualified fire alarm technician.

IsoroOwun to le FaOjutu
Pull station does not activate alarm.
  • Ti firanṣẹ ti ko tọ.
  • Ẹ̀rọ tí ó ní àṣìṣe.
  • Control panel issue.
  • Verify wiring connections and polarity.
  • Test the device with a multimeter (if qualified).
  • Check control panel status and error logs.
Pull station cannot be reset.
  • Ti lo bọtini ti ko tọ.
  • Internal mechanism jammed.
  • Ensure the correct reset key is used.
  • Do not force the mechanism; contact a technician for repair or replacement.
False alarms from pull station.
  • Physical damage or tampsisun.
  • Environmental factors (e.g., excessive vibration).
  • Wiring issues (e.g., short circuit).
  • Ṣayẹwo fun bibajẹ.
  • Ensure stable mounting.
  • Check wiring for shorts or loose connections.

7. Awọn pato

IwaẸ̀kúnrẹ́rẹ́
BrandSimplex
Nọmba awoṣe4099-9004
Nọmba apakan4099-9004
ApejuweSingle Action Addressable Manual Pull Station
Orisun agbaraManual (System Powered)
Àwọ̀Pupa
Iru ItanijiAudible (via connected system)
Iwọn Nkan13.7 iwon
Ọja Mefa6 x 5 x 4 inches
UPC647358696167

8. Atilẹyin ọja ati Support

For warranty information and technical support regarding your Simplex 4099-9004 Pull Station, please contact Simplex customer service or your authorized Simplex distributor. Keep your purchase receipt and product serial number handy for any inquiries.

Olupese: Simplex Grinnell

For further assistance, refer to the official Simplex webaaye tabi kan si awọn ikanni atilẹyin wọn taara.

Awọn iwe aṣẹ ti o jọmọ - 4099 9004

Ṣaajuview Simplex IDNet/MAPNET II Adirẹsi Afọwọkọ Ina Itaniji Ibusọ - Data ọja
Alaye alaye lori Simplex 4099 Series addressable Afowoyi ina itaniji ibudo, ni ibamu pẹlu IDNet ati MAPNET II awọn ọna šiše. Awọn ẹya ara ẹrọ, awọn pato, awọn aṣayan iṣagbesori, ati yiyan ọja fun ọpọlọpọ awọn awoṣe, pẹlu iṣe ẹyọkan, iṣe meji (gilasi fifọ ati titari), ati awọn aṣayan GRIP KO. Ni ibamu pẹlu awọn ibeere ADA ati atokọ nipasẹ UL, ULC, FM, ati CSFM.
Ṣaajuview Àwọn Ibùdó Ìtọ́sọ́nà Àdírẹ́sì Simplex: IDNet/MAPNET II Peripherals
Ṣawari awọn ibudo itaniji ina ti a le fi ọwọ ṣe, ṣe alaye awọn ẹya ara ẹrọ wọn, awọn iru iṣẹ kan/meji, awọn aṣayan KO GRIP, ati ibamu pẹlu awọn eto IDNet/MAPNET II. Pẹlu alaye fifi sori ẹrọ ati alaye ni pato.
Ṣaajuview Simplex 2099 Series Single and Double Action Manual Fire Alarm Stations Datasheet
Datasheet for Simplex 2099 Series non-coded, non-addressable manual fire alarm pull stations. Covers features, operation types, application references, product selection, mounting options, and specifications.
Ṣaajuview Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
Ṣaajuview Simplex 4007ES Fire Detection and Control Unit Datasheet
Detailed datasheet for the Simplex 4007ES Fire Detection and Control Unit, covering its MX Digital Addressable Initiation and Addressable Notification capabilities, features, specifications, and installation details.
Ṣaajuview Simplex 4010ES: Systèmes de commande d'extinction automatique pour gicleurs
Guide technique Simplex 4010ES détaillant les modules de commande pour les systèmes d'extinction automatique par gicleurs, couvrant les modes déluge et préventif, avec spécifications, homologations et schémas de câblage.