Ọrọ Iṣaaju
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the FW Murphy EGS21T-250-12 Temperature SWICHGAGE. This device is designed to monitor temperatures within a range of 0-250 degrees Fahrenheit and provide a switching output based on predefined temperature thresholds. Please read this manual thoroughly before installation and operation to ensure safe and proper use.
Alaye Aabo
Nigbagbogbo ṣe akiyesi awọn iṣọra aabo wọnyi:
- Disconnect all power sources before installation or maintenance.
- Rii daju pe iṣẹ voltage (12 VDC) matches the power supply.
- Installation should be performed by qualified personnel familiar with electrical and mechanical systems.
- Do not exceed the specified temperature range of 0-250°F.
- Protect the device from excessive vibration, moisture, and extreme temperatures outside its operating range.
- Ọja yii ni awọn kemikali ti a mọ si Ipinle California lati fa akàn ati awọn abawọn ibimọ tabi ipalara ibisi miiran. Fọ ọwọ lẹhin mimu.
Ọja Pariview
The FW Murphy EGS21T-250-12 is a robust temperature SWICHGAGE featuring a UV stabilized lens and a screw-on mounting clamp case. It provides accurate temperature readings and includes a normally open contact for switching applications.


The device is designed for panel mounting and utilizes screw terminals for secure electrical connections. Its compact dimensions make it suitable for various industrial and automotive applications.
Eto ati fifi sori
Follow these steps for proper installation of the EGS21T-250-12 SWICHGAGE:
- Igbaradi igbimọ: Cut a suitable opening in the mounting panel for the gauge. Refer to the product dimensions (4 x 4 x 4 inches) for appropriate sizing.
- Iṣagbesori: Insert the SWICHGAGE into the prepared opening. Secure it using the screw-on mounting clamp case. Ensure the gauge is firmly seated and stable.
- Awọn Isopọ Itanna:
- Identify the screw terminals on the rear of the unit (refer to Figure 2).
- Connect the 12 VDC power supply to the appropriate terminals. Observe polarity.
- Connect the normally open contact to your control circuit as required.
- Ensure all connections are tight and secure to prevent intermittent operation or damage.
- Ibi sensọ: Ensure the temperature sensing element (not explicitly shown but implied by "Temperature SWICHGAGE") is correctly positioned to accurately measure the desired temperature.
- Ṣayẹwo Ipari: Before applying power, double-check all connections and mounting to ensure everything is correct and secure.
Awọn ilana Iṣiṣẹ
The EGS21T-250-12 Temperature SWICHGAGE operates automatically once properly installed and powered.
- Agbara Tan: Apply 12 VDC power to the unit. The gauge needle will indicate the current temperature.
- Abojuto iwọn otutu: The gauge continuously monitors the temperature within its range of 0-250 degrees Fahrenheit.
- Iṣẹ Iyipada: The internal switch (normally open contact) will change state when the monitored temperature reaches a factory-set or user-adjustable (if applicable, not specified here) threshold. This can be used to trigger alarms, shut down systems, or activate cooling mechanisms.
- Kíkà Ìwé Gíga: Read the temperature directly from the dial (Figure 1).
Itoju
The FW Murphy EGS21T-250-12 SWICHGAGE is designed for minimal maintenance. However, periodic checks are recommended:
- Ninu: Gently wipe the UV stabilized lens with a soft, damp cloth to remove dust or debris. Do not use abrasive cleaners or solvents.
- Ṣayẹwo Asopọmọra: Periodically inspect electrical connections for tightness and signs of corrosion. Re-tighten screw terminals if necessary.
- Ayewo ti ara: Check the mounting and casing for any signs of damage or wear. Ensure the gauge remains securely mounted.
- Iṣatunṣe: This unit is factory calibrated. If you suspect inaccurate readings, contact FW Murphy customer support for assistance. Do not attempt to recalibrate the unit yourself.
Laasigbotitusita
If you encounter issues with your EGS21T-250-12 SWICHGAGE, refer to the following table:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Gauge not responding / No reading | Ko si agbara tabi onirin ti ko tọ. | Verify 12 VDC power supply is connected correctly and active. Check all screw terminal connections for tightness. |
| Kika iwọn otutu ti ko pe | Sensor improperly placed or damaged. Unit out of calibration. | Ensure the temperature sensor is correctly positioned and making good contact with the medium being measured. If problem persists, contact FW Murphy support. |
| Switching function not working | Incorrect wiring of the contact. Temperature not reaching threshold. Faulty contact. | Verify wiring of the normally open contact to your control circuit. Confirm the temperature is actually reaching the set point. If still not working, contact FW Murphy support. |
| Physical damage to lens or casing | Impact or improper handling. | Discontinue use if damage compromises safety or function. Contact FW Murphy for replacement parts or service. |
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | EGS21T-250-12 |
| Brand | FW Murphy |
| Iwọn otutu | 0-250 iwọn Fahrenheit |
| Awọn ọna Voltage | 12 Volts DC |
| Olubasọrọ Iru | Ṣii ni deede |
| Asopọmọra Iru | Clamp, Dabaru |
| Ebute Iru | Dabaru |
| Iṣagbesori Iru | Panel Oke |
| Actuator Iru | Gbona |
| Awọn Iwọn Nkan (L x W x H) | 4 x 4 x 4 inches |
| Iwọn Nkan | 1 iwon |
| Ohun elo | Ejò (Ohun èlò ìfọwọ́kàn) |
| International Idaabobo Rating | IP00 |
| UPC | 650056083863 |
Alaye atilẹyin ọja
FW Murphy products are manufactured to high standards. For specific warranty terms and conditions applicable to the EGS21T-250-12, please refer to the warranty documentation included with your purchase or visit the official FW Murphy website. Typically, warranties cover defects in materials and workmanship under normal use.
Onibara Support
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact FW Murphy customer support. Have your model number (EGS21T-250-12) and purchase details ready when contacting support.
You can find contact information on the official FW Murphy webaaye tabi nipasẹ olupin ti a fun ni aṣẹ.