COTEK SP-3000-112

Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter User Manual

Model: SP-3000-112

1. Ifihan

This manual provides essential information for the safe and efficient operation of your Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter. This device converts 12V DC power from batteries into 120V AC power, suitable for a wide range of electronic appliances. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Alaye Aabo

Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always exercise caution when working with electrical equipment.

Illustration of a battery with a recycling symbol
Always handle batteries with care and ensure proper disposal.
Hard hat, safety glasses, and gloves on a wooden surface
Wọ ohun elo aabo ara ẹni ti o yẹ lakoko fifi sori ẹrọ ati itọju.

3. Ọja Ipariview

3.1 Key Awọn ẹya ara ẹrọ

3.2 Àwọn Ẹ̀yà Inverter

Cotek SP-3000-112 Pure Sine Wave Inverter, front-side view
Nọmba 1: Lapapọ view of the Cotek SP-3000-112 Pure Sine Wave Inverter. This image shows the robust blue and grey casing, ventilation grilles, and the general form factor of the unit.
Rear panel of the Cotek SP-3000-112 Inverter showing AC outlet and controls
Nọmba 2: Rear panel of the inverter. Visible components include the hardwire AC output terminal, the main power switch (ON/OFF), LED indicators, DIP switches for settings, and an RJ45 port for remote control.
Front panel of the Cotek SP-3000-112 Inverter showing DC input terminals and cooling fan
Nọmba 3: Front panel of the inverter. This view highlights the heavy-duty DC input terminals (red for positive, black for negative), the chassis ground connection, and the cooling fan vents.
Close-up of the control panel on the Cotek SP-3000-112 Inverter
Nọmba 4: Alaye view of the control panel. This section includes the LED indicators (Power, Fault, Overload), DIP switches for configuration, the RJ45 remote control port, and the green terminal for remote ON/OFF control.

4. Eto ati fifi sori

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to local electrical codes and standards.

4.1 Ibi

4.2 Onirin

All wiring must comply with applicable electrical codes and be performed by a qualified electrician.

  1. Ilẹ: Connect the inverter's chassis ground terminal to a reliable earth ground using appropriate gauge wire.
  2. Asopọ igbewọle DC:
    • Ensure the battery bank voltage jẹ 12VDC.
    • Use appropriately sized cables for the DC input to minimize voltage drop and ensure safety. Refer to cable sizing charts based on current and distance.
    • Connect the positive (+) terminal of the battery bank to the red (+) terminal on the inverter.
    • Connect the negative (-) terminal of the battery bank to the black (-) terminal on the inverter.
    • Install a DC-rated fuse or circuit breaker between the battery bank and the inverter's positive terminal, as close to the battery as possible.
  3. Asopọ jade AC:
    • Connect your AC loads to the hardwire AC output terminal block.
    • Ensure the total load does not exceed the inverter's continuous power rating (3000W).
  4. Iṣakoso Latọna jijin (Aṣayan): Connect the remote control unit to the RJ45 port or use the green terminal for external ON/OFF control if desired.

5. Awọn ilana Iṣiṣẹ

5.1 Titan / Pa a

  1. Lati Fi agbara: Ensure all DC and AC connections are secure. Flip the main power switch on the inverter's rear panel to the 'ON' position. The Power LED indicator should illuminate.
  2. Lati Paarẹ: Disconnect all AC loads from the inverter. Flip the main power switch to the 'OFF' position.

5.2 LED Atọka

The inverter features 3-color LED status indicators on the control panel (refer to Figure 4) to provide operational feedback:

5.3 DIP Yipada Eto

The DIP switches on the control panel allow for customization of certain inverter parameters, such as output voltage, frequency, and power saving mode. Refer to the detailed specifications table (Figure 5) or the product datasheet for specific configurations. Always adjust DIP switches when the inverter is powered off.

6. Itọju

Regular maintenance ensures the longevity and reliable operation of your inverter.

7. Laasigbotitusita

Apá yìí fún wa ní ìdáhùn sí àwọn ìṣòro tó wọ́pọ̀ tí o lè bá pàdé. Tí ìṣòro náà bá ń bá a lọ, kan si olùrànlọ́wọ́ oníbàárà.

IsoroOwun to le FaOjutu
Inverter ko tan.No DC input power; Loose battery connections; Blown DC fuse/breaker; Inverter switch OFF.Ṣayẹwo batiri voltage; Tighten connections; Replace fuse/reset breaker; Turn inverter switch ON.
Ko si iṣẹ AC.Overload; Short circuit; Over-temperature shutdown; Low/High DC input voltage.Reduce AC load; Check for short circuits in wiring/appliances; Allow inverter to cool; Check battery voltage.
Yellow LED illuminated.Low batiri voltage warning; High temperature warning.Recharge batteries; Ensure adequate ventilation, reduce load.
Red LED illuminated / Inverter shut down.Overload; Short circuit; Over-temperature; Under/Over voltage.Identify and correct the fault (e.g., reduce load, fix short, allow cooling, check battery voltage), then restart the inverter.
Cooling fan runs constantly or loudly.High internal temperature due to heavy load or poor ventilation.Reduce load; Improve ventilation around the inverter.

8. Awọn pato

The following table outlines the technical specifications for the Cotek SP-3000 Series Pure Sine Wave Inverter, specifically for the SP-3000-112 model.

Detailed specifications table for Cotek SP-3000 series inverters
Nọmba 5: Technical specifications for the Cotek SP-3000 Series, including the SP-3000-112 model.
ẸkaParamitaSP-3000-112
AbajadeAC Voltage100/110/115/120VAC ±5%
Ti won won Agbara3000W
Surge Power (1 Sec.)6000W
Agbara Ijade ti o pọju (1 min)3450W
Iwajade WaveformPure Sine Wave (THD<3%)
Igbohunsafẹfẹ50/60 Hz ± 0.5%
IṣawọleDC Voltage12VDC
Voltage Ibiti10.5 ~ 16.5VDC
Ko si fifuye Lọwọlọwọ<3.0A @ 12VDC
Ipo fifipamọ agbara<0.4A @ 12VDC
Imudara (Max.)90%
IdaaboboInput Under - Voltage Idaabobo10.5 ± 0.3VDC
Input Under - Voltage Itaniji11.0 ± 0.3VDC
Input Under - Voltage Ìgbàpadà12.0 ± 0.3VDC
Input Over - Voltage Idaabobo16.5 ± 0.3VDC
Input Over - Voltage Ìgbàpadà14.5 ± 0.3VDC
Ijade ApọjuTiipa o wu voltage, tun bẹrẹ lati bọsipọ
O wu KukuruTiipa o wu voltage, tun bẹrẹ lati bọsipọ
AyikaIwọn otutu nṣiṣẹ.-20°C ~ +40°C
Ibi ipamọ otutu. & Ọriniinitutu-30°C ~ +70°C, 10 ~ 95% RH
GbogboogboAwọn iwọn (W x H x D)442 x 214 x 102 mm (17.4 x 8.4 x 4.0 inches)
Iwọn8.2kg (18.1 lbs)
Itutu agbaiyeAfẹfẹ itutu iṣakoso iwọn otutu & fifuye
Mechanical drawings with dimensions for Cotek SP-3000 series inverter
Nọmba 6: Mechanical drawings providing dimensional information for installation planning.

9. Atilẹyin ọja ati Support

9.1 atilẹyin ọja Alaye

The Cotek SP-3000-112 Pure Sine Wave Inverter comes with a 2-Odun olupese atilẹyin ọja. Atilẹyin ọja yi ni wiwa awọn abawọn ninu awọn ohun elo ati iṣẹ ṣiṣe labẹ lilo deede. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.

9.2 Onibara Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cotek customer support through their official website or your point of purchase. Provide your model number (SP-3000-112) and a detailed description of the issue to expedite service.

Awọn iwe aṣẹ ti o jọmọ - SP-3000-112

Ṣaajuview COTEK SP Series Pure Sine Wave Inverter ká Afowoyi
Iwe afọwọkọ olumulo pipe fun COTEK SP Series Pure Sine Wave Inverters (SP-700 si SP-4000). Kọ ẹkọ nipa fifi sori ẹrọ, iṣẹ ṣiṣe, ailewu, awọn pato imọ-ẹrọ, ati awọn ẹya ilọsiwaju bii iṣelọpọ igbi omi mimọ ati aabo to lagbara.
Ṣaajuview COTEK SP Series Pure Sine Wave Inverter ká Afowoyi
Comprehensive user's manual for COTEK SP Series Pure Sine Wave Inverters (SP-700, SP-1000, SP-1500, SP-2000, SP-3000, SP-4000). Covers specifications, installation, operation, safety, and RS-232 communication for reliable power conversion.
Ṣaajuview COTEK SPT Series Pure Sine Wave Inverter with Transfer Switch - Product Introduction and Specifications
A ṣoki ti pariview of the COTEK SPT Series Pure Sine Wave Inverters with Transfer Switch, detailing their technical specifications, product appearance, installation guidelines, and warranty information for various models.
Ṣaajuview COTEK SE Series Pure Sine Wave Inverter User Manual (200W, 350W, 400W)
Comprehensive user manual for the COTEK SE Series Pure Sine Wave Inverters, covering models 200W, 350W, and 400W. This guide provides detailed information on safety precautions, product features, electrical specifications, installation procedures, operation, maintenance, troubleshooting, and warranty details.
Ṣaajuview COTEK SK Series 1500W Pure Sine Wave Inverter User's Manual
Comprehensive user's manual for the COTEK SK Series 1500W Pure Sine Wave Inverter, covering safety, features, specifications, installation, operation, maintenance, and troubleshooting. Provides detailed guidance for proper use and care.
Ṣaajuview COTEK SK120, SK200, SK350 Series Pure Sine Wave Inverter Afọwọṣe olumulo
Iwe afọwọkọ olumulo yii n pese alaye alaye lori COTEK SK120, SK200, ati jara SK350 awọn inverters sine igbi mimọ, aabo ibora, awọn ẹya, fifi sori ẹrọ, iṣẹ ṣiṣe, laasigbotitusita, ati atilẹyin ọja.