1. Ifihan
1.1 Ọja Loriview
The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.
1.2 Abo Alaye
Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.
- Ge asopọ agbara nigbagbogbo ṣaaju ṣiṣe eyikeyi fifi sori ẹrọ tabi itọju.
- Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
- Daju pe awọn ipese agbara voltage matches the pump's requirements (230 Volts AC).
- Do not operate the pump with damaged cables or connections.
- Wọ ohun elo aabo ara ẹni ti o yẹ (PPE) nigbati o ba n lo awọn kemikali tabi ṣe itọju.
2. Eto ati fifi sori
2.1 Iṣagbesori fifa soke
Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.
2.2 Itanna Asopọ
The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.
2.3 Fluid Connections
Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.
3. Awọn ilana Iṣiṣẹ
3.1 Ibẹrẹ ibẹrẹ
- Ensure all fluid connections are secure and the pump is properly mounted.
- Verify that the fluid source is available and the discharge line is correctly routed.
- Plug the pump into the power supply.
3.2 Flow Regulation
The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).
4. Itọju
4.1 Gbogbogbo Itọju
- Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
- Check all connections for leaks and tighten if required.
- Keep the pump's exterior clean and free from dust and debris.
4.2 Ninu
To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.
5. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | Ko si ipese agbara Okun agbara ti bajẹ | Ṣayẹwo asopọ agbara ati iṣan Inspect and replace cable if damaged |
| Ko si ṣiṣan omi | Tubing kinked tabi dina Àlẹmọ agbawole dí Potentiometer set to 0% | Inspect and clear tubing Nu tabi ropo agbawole àlẹmọ Adjust potentiometer to desired flow rate |
| Inconsistent flow | Afẹfẹ ni ila Worn tubing | Afẹfẹ ẹjẹ lati inu eto naa Replace peristaltic tubing |
| Jijo ni awọn asopọ | Awọn isopọ alaimuṣinṣin Damaged seals/tubing | Mu gbogbo awọn asopọ pọ Inspect and replace seals or tubing |
6. Imọ ni pato
| Sipesifikesonu | Iye |
|---|---|
| Brand | Astralpool |
| Nọmba awoṣe | 57178 |
| Awọn iwọn Ọja (L x W x H) | 23 x 11 x 13 cm |
| Iwọn | 900 giramu |
| Voltage | 230 Volt (AC) |
| Oṣuwọn sisan | Up to 12 L/H (continuously adjustable) |
| Ipa ti o pọju | 1 igi |
| Apoju Awọn ẹya ara wiwa | Alaye ko si |