The BRESSER Temeo Quadro Temperature Station is designed to monitor temperature and humidity at up to four different locations simultaneously. This system includes a main display unit and three remote sensors, allowing you to track environmental conditions both indoors and outdoors, or in various rooms of your home. The remote sensors transmit data wirelessly to the main unit via a 433 MHz radio signal.

Alaye Aabo

  • Ka gbogbo awọn ilana ni pẹkipẹki ṣaaju lilo ẹrọ naa.
  • Jeki iwe afọwọkọ yii fun itọkasi ọjọ iwaju.
  • Ma ṣe fi ẹrọ naa han si awọn iwọn otutu to gaju, imọlẹ orun taara, tabi ọriniinitutu giga.
  • Yago fun sisọ silẹ tabi tẹriba ẹrọ si awọn ipa to lagbara.
  • Ma ṣe gbiyanju lati tunto tabi tun ẹrọ naa funrararẹ. Kan si oṣiṣẹ iṣẹ ti o peye.
  • Sọ awọn batiri ti a lo ni ifojusọna ni ibamu si awọn ilana agbegbe.

Package Awọn akoonu

  • 1x BRESSER Temeo Quadro Main Display Unit
  • 3x Remote Sensors
  • 1x Itọsọna olumulo (iwe yii)

Note: Batteries are not included. The main unit requires 3x AAA (LR03) batteries, and each remote sensor requires 2x AAA (LR03) batteries.

Ọja Pariview

Akọkọ Ifihan Unit

Iwaju view of the BRESSER Temeo Quadro main unit display.

Aworan: Iwaju view of the BRESSER Temeo Quadro main unit display. A clear view of the main unit's LCD screen, showing temperature and humidity values for four channels.

Ẹyìn view of the BRESSER Temeo Quadro main unit, showing control buttons and battery compartment.

Aworan: Ẹyìn view of the BRESSER Temeo Quadro main unit, showing control buttons and battery compartment. The back of the main unit includes buttons for 'CHANNEL', 'ALARM', 'MAX/MIN', and 'SET', along with the battery compartment cover.

  • Ifihan LCD: Shows temperature and humidity for the main unit (IN) and up to three remote sensors (1, 2, 3).
  • Bọ́tìnì Ìkànnì: Selects which remote sensor's data is displayed or cycles through channels.
  • Bọtini itaniji: Activates/deactivates temperature/humidity alarms.
  • Bọtini Max/MIN: Displays maximum and minimum recorded values.
  • Ṣeto Bọtini: Ó wọ ipo iṣeto fun akoko, ọjọ, ati awọn eto itaniji.
  • Abala Batiri: Located on the rear, for 3x AAA batteries.
  • Iduro Ijọpọ: For desktop placement.

Sensọ latọna jijin

BRESSER Temeo Quadro remote sensor, front and back views.

Aworan: BRESSER Temeo Quadro remote sensor, front and back views. A remote sensor unit, showing its display on the front and the battery compartment and mounting hole on the back.

  • Ifihan LCD: Shows its current temperature and humidity.
  • Yipada ikanni: Allows selection of channel 1, 2, or 3.
  • Abala Batiri: For 2x AAA batteries.
  • Iho iṣagbesori: Fun iṣagbesori odi.

Ṣeto

1. Fifi sori batiri

  1. For Remote Sensors:
    • Open the battery compartment cover on the back of each remote sensor.
    • Insert 2x AAA (LR03) batteries into each sensor, observing the correct polarity (+/-).
    • Set the channel switch (1, 2, or 3) on each sensor to a unique channel.
    • Pa ideri iyẹwu batiri naa.
  2. For Main Display Unit:
    • Ṣii ideri iyẹwu batiri ni ẹhin ẹyọ akọkọ.
    • Insert 3x AAA (LR03) batteries, observing the correct polarity (+/-).
    • Close the battery compartment cover. The main unit will power on and begin searching for sensor signals.

2. Sensọ Sisopọ

  • After installing batteries in both the sensors and the main unit, the main unit will automatically attempt to connect with the remote sensors.
  • Ensure the remote sensors are within range (typically up to 30 meters in open air) of the main unit during initial setup.
  • The corresponding channel numbers (1, 2, 3) on the main unit's display will show readings once a connection is established. The 'IN' channel displays the main unit's internal readings.
  • If a sensor does not connect, remove and reinsert its batteries, then press the 'CHANNEL' button on the main unit to initiate a new search.

3. Ifiweranṣẹ

  • Place the main unit indoors in a central location, away from direct sunlight or heat sources.
  • Position remote sensors in desired monitoring areas. For outdoor use, place sensors in a sheltered spot to protect them from direct rain and sun, which can affect accuracy and device longevity.

Awọn ilana Iṣiṣẹ

Viewing Awọn iwọn otutu ati ọriniinitutu

  • The main display unit continuously shows the current temperature and humidity for the internal sensor ('IN') and the three remote sensors (1, 2, 3).
  • The display also indicates comfort levels (e.g., 'COM' for comfortable, 'DRY' for dry, 'WET' for wet) based on humidity levels.

MAX/MIN Records

  • Tẹ awọn MAX/MIN button once to display the maximum temperature and humidity recorded since the last reset.
  • Tẹ awọn MAX/MIN button a second time to display the minimum temperature and humidity recorded.
  • To clear the MAX/MIN records, press and hold the MAX/MIN button for approximately 3 seconds while MAX or MIN values are displayed.

Aṣayan Iwọn otutu (°C/°F)

  • On the main unit, press the SET button to toggle between Celsius (°C) and Fahrenheit (°F).

Setting Alarms (if applicable)

  • Tẹ awọn Itaniji bọtini lati tẹ ipo itaniji sii.
  • Lo awọn CHANNEL ati MAX/MIN buttons to adjust the desired high and low temperature/humidity alarm thresholds for each channel.
  • Tẹ Itaniji again to confirm settings and activate the alarm. An alarm icon will appear on the display.
  • When an alarm threshold is met, the unit will emit an audible alert and the corresponding channel's reading will flash.

Itoju

  • Ninu: Nu ẹrọ naa pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
  • Rirọpo Batiri: Replace batteries when the low battery indicator appears on the display. Always replace all batteries in a unit at the same time.
  • Ibi ipamọ: Tí o bá ń tọ́jú ẹ̀rọ náà fún ìgbà pípẹ́, yọ gbogbo bátìrì kúrò kí ó má ​​baà jò.

Laasigbotitusita

IsoroOwun to le FaOjutu
Ko si ifihan lori akọkọ kuro.Awọn batiri ti ku tabi fi sii lọna ti ko tọ.Ṣayẹwo polarity batiri ki o si ropo pẹlu awọn batiri AAA tuntun.
Remote sensor not displaying data on main unit.Sensor out of range, incorrect channel setting, or dead batteries.
  • Gbe sensọ sunmọ ẹyọ akọkọ.
  • Ensure sensor channel switch matches the desired channel on the main unit.
  • Rọpo awọn batiri sensọ.
  • Press the 'CHANNEL' button on the main unit to re-scan for sensors.
Awọn kika ti ko pe.Sensọ tí a fi sí ojú oòrùn tààrà, àwọn orísun ooru, tàbí ọrinrin.Relocate sensors to a more appropriate, sheltered environment. Allow time for readings to stabilize.
Intermittent signal loss.Interference from other electronic devices or physical obstructions.Move the main unit or sensors away from potential sources of interference (e.g., TVs, microwaves, large metal objects).

Awọn pato

Nọmba awoṣe7000020CM3000
BrandBRESSER
Awọn iwọn Ọja (Ẹka akọkọ)1.02 x 4.13 x 4.72 inches (2.59 x 10.49 x 11.99 cm)
Item Weight (Main Unit)0.19 kilo (iwọn 6.7 iwon)
Temperature Range (Main Unit)Internal sensor range not specified, but upper rating is 55 °C.
Yiye iwọn otutu±1 °C
Ibiti ọriniinitutuNot specified, but typically 20% to 95% for similar devices.
Alailowaya Igbohunsafẹfẹ433 MHz
Orisun Agbara (Ẹka Akọkọ)3x AAA (LR03) batteries
Power Source (Remote Sensor)2x AAA (LR03) batteries per sensor
Number of Remote Sensors Supported3

Atilẹyin ọja

This BRESSER product comes with a meji-odun atilẹyin ọja against factory defects from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper use, accidents, unauthorized repairs, or normal wear and tear.

Atilẹyin

For technical support, warranty claims, or further information, please visit the official BRESSER website or contact their customer service department. Refer to the packaging or the BRESSER webAaye fun awọn alaye olubasọrọ lọwọlọwọ julọ.

Online resources may include FAQs, additional manuals, and contact forms.

Awọn iwe aṣẹ ti o jọmọ - 7000020CM3000

Ṣaajuview Bresser ClimaTrend Hygro Quadro Digital Thermo-Hygrometer User Manual
Comprehensive instruction manual for the Bresser ClimaTrend Hygro Quadro digital thermo-hygrometer, detailing setup, operation, alarm functions, and specifications. Includes model numbers 7000020CM3000, 7000020GYE000, 7000020QT5000.
Ṣaajuview Bresser ClimaTrend Hygro Quadro Wireless Weather Station Instruction Manual
Comprehensive instruction manual for the Bresser ClimaTrend Hygro Quadro wireless weather station, covering setup, operation, features, alarm settings, comfort level, declarations, maintenance, warranty, and contact information.
Ṣaajuview BRESSER Thermo-/Hygrometer Quadro mit 3 Außensensoren Bedienungsanleitung
Umfassende Bedienungsanleitung für das BRESSER Thermo- / Hygrometer Quadro. Erfahren Sie mehr über Einrichtung, Bedienung, Funktionen und Wartung für präzise Innen- und Außentemperatur- und Luftfeuchtigkeitsmessungen.
Ṣaajuview Bresser ClimaTrend Hygro Quadro Ilana itọnisọna
Itọsọna okeerẹ fun ibudo oju ojo Bresser ClimaTrend Hygro Quadro, iṣeto alaye, iṣẹ ṣiṣe, awọn ẹya bii ibojuwo sensọ pupọ, awọn aṣa iwọn otutu, awọn ipele itunu, ati awọn itaniji fun awọn awoṣe 7000020CM3000, 7000020GYE000, 7000020QT5000.
Ṣaajuview BRESSER Quadro NV Ilana itọnisọna Thermo-Hygrometer
Ilana itọnisọna pipe fun BRESSER Quadro NV Thermo-Hygrometer, iṣeto ibora, awọn ẹya ara ẹrọ, awọn alaye imọ-ẹrọ, ati alaye ailewu ni awọn ede pupọ.
Ṣaajuview BRESSER Quadro NV Ilana itọnisọna Thermo-Hygrometer
Iwe itọnisọna pipe fun BRESSER Quadro NV Thermo-Hygrometer, iṣeto ibora, awọn iṣẹ ṣiṣe, awọn alaye imọ-ẹrọ, ati didanu. Pẹlu awọn itumọ ede pupọ.