WTW 103644 Model Sentix H pH Electrode User Manual

Model: 0916A26EA

Ọrọ Iṣaaju

The WTW Sentix H pH Electrode is specifically designed for challenging measurements, particularly in high alkaline solutions. This specialized electrode ensures accurate pH readings even in low-ion samples or when dealing with very small volumes. Its robust design and advanced features make it a reliable tool for various laboratory and industrial applications.

WTW Sentix H pH Electrode with S7 Plug Head

Nọmba 1: WTW Sentix H pH Electrode. This image displays the full length of the electrode, highlighting its slender body, the S7 plug head at the top, and the sensing bulb at the bottom. The blue labeling on the electrode body is also visible.

Ṣeto

Proper setup is crucial for optimal performance of your Sentix H pH Electrode. Follow these steps:

  1. Ṣii silẹ: Carefully remove the electrode from its packaging. Inspect for any visible damage.
  2. Storage Solution Removal: The electrode tip is typically protected by a cap containing a storage solution. Remove this cap. Do not discard the cap or solution, as it is needed for storage.
  3. Rinsin: Rinse the electrode tip thoroughly with distilled or deionized water to remove any residual storage solution. Gently blot dry with a lint-free tissue.
  4. Connecting to Meter: Connect the S7 plug head of the electrode to the corresponding S7 input port on your compatible pH meter. Ensure a secure connection.
  5. Pre-conditioning (if necessary): For new electrodes or those that have been stored dry, immerse the electrode tip in a suitable electrode storage solution or pH 7 buffer for at least 30 minutes to an hour before first use.

Awọn ilana Iṣiṣẹ

The Sentix H electrode is optimized for high alkaline solutions. Adhere to the following operational guidelines:

Itoju

Regular maintenance extends the lifespan and ensures the accuracy of your electrode:

Laasigbotitusita

Tí o bá ní ìṣòro, wo tábìlì ní ìsàlẹ̀ yìí fún àwọn ìṣòro àti ìdáhùn tó wọ́pọ̀:

IsoroOwun to le FaOjutu
Unstable or Drifting Readings
  • Dirty or clogged junction
  • Insufficient immersion
  • Awọn iyipada iwọn otutu
  • Old or contaminated buffers
  • Air bubbles on sensing bulb
  • Clean electrode as per maintenance section
  • Ensure proper immersion depth
  • Gba sample/electrode to equilibrate to temperature
  • Use fresh buffer solutions
  • Gently tap electrode to dislodge bubbles
Àkókò Ìdáhùn Díẹ̀díẹ̀
  • Ogbe ti gbẹ
  • Ipade didimu
  • Old electrode
  • Recondition electrode by soaking in storage solution
  • Elekiturodu mimọ
  • Consider electrode replacement
Inaccurate Readings / Calibration Failure
  • Incorrect calibration procedure
  • Contaminated buffers
  • Elekiturodu ti bajẹ
  • Incorrect temperature compensation
  • Review pH meter manual for calibration steps
  • Use fresh, accurate buffers
  • Inspect electrode for physical damage
  • Verify temperature settings

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Orukọ awoṣeSentix H pH Electrode
Nọmba Awoṣe Nkan0916A26EA
OlupeseWTW
ASINB01N7MVTLV
Ohun eloHigh Alkaline Solutions, Low-ion Samples, Small Volumes
Pulọọgi OriS7
Key Awọn ẹya ara ẹrọSpecial glass membranes, adapted diaphragm technique

Atilẹyin ọja ati Support

For information regarding warranty coverage, technical support, or service, please contact WTW directly or refer to their official website. Keep your purchase receipt and model number handy for faster assistance.

Olupese: WTW

Awọn iwe aṣẹ ti o jọmọ - 0916A26EA

Ṣaajuview WTW SenTix® 950 / 980 / Micro 900(-P) pH Electrode Operating Manual
This operating manual provides comprehensive instructions for the WTW SenTix® 950, 980, and Micro 900(-P) pH electrodes with liquid electrolyte. It covers essential topics including automatic sensor recognition, commissioning, calibration procedures, measurement guidelines, proper storage, maintenance and cleaning, detailed technical specifications, available accessories, and disposal information.
Ṣaajuview WTW-PDRP4620EASD3/4630ESD3 カメラ 取扱説明書:メニュー設定と安全ガイド
この取扱説明書は、WTW-PDRP4620EASD3 および WTW-PDRP4630ESD3 ドームカメラのOSDメニュー設定、基本接続、および安全上の注意事項を解説します。製品のセットアップと安全な使用に必要な情報を提供します。
Ṣaajuview WTW Camera OSD Menu and Connection Guide
Comprehensive guide to connecting WTW surveillance cameras and configuring their On-Screen Display (OSD) menu settings, covering video modes, exposure, day/night settings, and more. Includes detailed connection diagrams and setup instructions.
Ṣaajuview WTW セキュリティカメラシステム 取扱説明書:安全上の注意とメニュー設定
WTW製セキュリティカメラシステムの安全上の注意、基本接続方法、およびOSDメニュー設定に関する詳細な取扱説明書。カメラ設定、ビデオモード、言語選択、露出調整などの機能について解説。
Ṣaajuview WTW-WSP12-BM / WSP18-BM / WSP21-BM IPカメラ 取扱説明書
塚本無線 WTW-WSP12-BM, WTW-WSP18-BM, WTW-WSP21-BM IPカメラの取扱説明書。設置、設定、機能、トラブルシューティング、保証に関する詳細情報。
Ṣaajuview WTW-EGDRY388GWX/GBX IP Camera User Manual
This manual provides instructions for setting up, registering, and using the WTW-EGDRY388GWX/GBX IP Camera, including app installation, camera configuration, motion detection, recording, playback, sharing, and troubleshooting.