1. Ifihan
This manual provides essential instructions for the safe installation, operation, and maintenance of your KING KB2407-1-B2-ECO ECO2S 7500W Garage Heater. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and adherence to these instructions are crucial for optimal performance and safety.
2. Alaye Aabo pataki
ÌKÌLỌ̀: Ewu Iná, Ìpalára Iná Mọ̀nàmọ́ná, tàbí Ìpalára fún Àwọn Ènìyàn.
- Ka gbogbo awọn ilana ṣaaju fifi sori ẹrọ tabi lilo ẹrọ igbona.
- This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains, at least 3 feet (0.9 m) from the front of the heater and keep them away from the sides and rear.
- Išọra to gaju jẹ dandan nigbati ẹrọ igbona eyikeyi ba nlo nipasẹ tabi sunmọ awọn ọmọde tabi awọn alaiṣe ati nigbakugba ti ẹrọ igbona ba ṣiṣẹ ati laini abojuto.
- Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped, or damaged in any manner. Discard heater or return to authorized service facility for examination and/or repair.
- Maṣe lo ni ita.
- Olugbona yii ko ṣe ipinnu fun lilo ninu awọn balùwẹ, awọn agbegbe ifọṣọ, ati awọn ipo inu ile ti o jọra. Maṣe wa ẹrọ igbona nibiti o le ṣubu sinu iwẹ tabi apo omi miiran.
- Ma ṣe ṣiṣe okun labẹ capeti. Ma ṣe bo okùn pẹlu awọn rogi jiju, awọn asare, tabi awọn ibora ti o jọra. Ṣeto okun kuro ni agbegbe ijabọ ati nibiti kii yoo ṣe kọlu.
- Lati ge asopọ ẹrọ igbona, tan awọn idari si pipa, lẹhinna yọ plug kuro ni iṣan.
- Ma ṣe fi sii tabi gba awọn ohun ajeji laaye lati wọ inu afẹfẹ eyikeyi tabi ṣiṣi eefin nitori eyi le fa ina mọnamọna tabi ina, tabi ba ẹrọ igbona jẹ.
- Lati ṣe idiwọ ina ti o ṣeeṣe, maṣe dina awọn gbigbe afẹfẹ tabi eefi ni eyikeyi ọna. Ma ṣe lo lori awọn aaye rirọ, bii ibusun, nibiti awọn ṣiṣi le di dina.
- A ti ngbona ni gbona ati arcing tabi sparking awọn ẹya ara inu. Ma ṣe lo ni awọn agbegbe nibiti epo petirolu, kikun, tabi awọn ina ina tabi awọn olomi ti wa ni lilo tabi tọju.
- Lo ẹrọ igbona yii nikan gẹgẹbi a ti ṣalaye ninu iwe afọwọkọ yii. Lilo eyikeyi miiran ti a ko ṣeduro nipasẹ olupese le fa ina, mọnamọna, tabi ipalara si awọn eniyan.
- Nigbagbogbo pulọọgi awọn igbona taara sinu iṣan ogiri kan/apoti. Maṣe lo pẹlu okun itẹsiwaju tabi fọwọkan agbara ti o ṣee gbe (ibọsẹ/adiha agbara).
- This heater is for 240V applications only.
3. Package Awọn akoonu
Verify that all components are present and undamaged. If any items are missing or damaged, contact your retailer.
- KING KB2407-1-B2-ECO ECO2S Garage Heater (7500W / 240V)
- Universal Wall/Ceiling Mounting Bracket
- Isakoṣo latọna jijin
- Afowoyi Olumulo (iwe-ipamọ yii)

Image 3.1: The KING KB2407-1-B2-ECO ECO2S Garage Heater, showing the main unit, the universal mounting bracket, and the remote control.
4. Eto ati fifi sori
Fifi sori gbọdọ jẹ ṣiṣe nipasẹ onisẹ ina mọnamọna ni ibamu pẹlu gbogbo awọn koodu itanna agbegbe ati ti orilẹ-ede.
4.1 Iṣagbesori Location
- Select a location where the heater is protected from water spray, dripping water, and excessive dust.
- Ensure adequate clearance from combustible materials (minimum 3 feet from front, sides, and rear).
- Mount the heater securely to a structural member (stud, joist) capable of supporting its weight (approximately 33.5 lbs).
- The universal bracket allows for wall or ceiling mounting.
4.2 Iṣagbesori awọn ti ngbona
- Attach the universal mounting bracket to a sturdy wall stud or ceiling joist using appropriate fasteners (not included). Ensure the bracket is level and securely fastened.
- Lift the heater and align the hanging hooks on top of the heater with the slots on the mounting bracket.
- Slide the heater onto the bracket until it is securely seated.
- Adjust the heater's angle as desired and secure it using the provided hardware to prevent accidental movement.
4.3 Itanna onirin
DANGER: Disconnect power at the main service panel before attempting any wiring to prevent electric shock.
- This heater requires a dedicated 240V circuit.
- The heater is rated for 7500W, drawing approximately 31.25 Amps. A circuit breaker and wiring sized appropriately for this load are required (e.g., 40 Amp breaker with 8-gauge wire, consult local codes).
- Access the internal wiring compartment by removing the appropriate cover plate on the heater.
- Connect the 240V supply wires to the heater's terminals as indicated in the wiring diagram inside the heater's compartment. Ensure proper grounding.
- Secure all wiring connections and replace the cover plate.

Aworan 4.1: Ẹyin view of the heater, illustrating the fan and location of electrical warning labels. Ensure all wiring is done by a qualified professional.
5. Isẹ
Once properly installed and powered, the heater can be operated using its integrated control panel or the remote control.
5.1 Iṣakoso igbimo Loriview

Aworan 5.1: Iwaju view of the heater, highlighting the digital display and control buttons for direct operation.
Pẹnu iṣakoso naa ni ifihan oni-nọmba kan ati awọn bọtini pupọ:
- Ifihan Digital: Shows current temperature, set temperature, and mode indicators.
- Bọtini AGBARA: Yi ẹrọ ti ngbona Tan/PA.
- Bọtini MODE: Cycles through heating modes (ECO, HIGH, FAN ONLY).
- Awọn itọka oke/isalẹ: Adjusts the set temperature.
- Bọtini TIMER: Activates or adjusts the timer function.
5.2 Iṣakoso latọna jijin
Iṣakoso latọna jijin ti o wa ninu rẹ pese iwọle si gbogbo awọn iṣẹ igbona lati ijinna kan.
- Ensure batteries are correctly installed in the remote control.
- Point the remote control towards the heater's control panel for optimal signal reception.
- Buttons on the remote mirror the functions of the control panel (Power, Mode, Up/Down Temperature, Timer).
5.3 Awọn ọna ṣiṣe
- Ipo ECO: The heater automatically selects the lowest wattage needed to maintain the set temperature, optimizing energy consumption.
- HIGH Heat Mode: The heater operates at full wattage (7500W) to quickly reach and maintain the set temperature.
- FAN ONLY Mode: The fan operates without engaging the heating elements, providing air circulation.
5.4 Ṣiṣeto iwọn otutu
- Press the POWER button to turn the heater on.
- Use the UP or DOWN arrow buttons to set your desired temperature. The display will show the set temperature, then revert to the ambient temperature.
- The heater will automatically cycle on and off to maintain the set temperature.
5.5 Aago Išė
The timer allows you to set a duration for the heater to operate before automatically turning off.
- With the heater on, press the TIMER button.
- Use the UP or DOWN arrow buttons to set the desired operating time (e.g., 1-12 hours).
- The heater will operate for the set duration and then power off.
6. Itọju
WARNING: Always disconnect power to the heater at the main service panel before performing any maintenance or cleaning.
- Ninu: Lorekore nu ode ti igbona pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.
- Yiyọ eruku kuro: Use a vacuum cleaner with a brush attachment to remove dust from the grilles and internal components. Ensure the fan blades are free of obstructions.
- Ayewo: Regularly inspect the power cord and plug for any signs of damage. If damage is found, discontinue use and contact a qualified electrician for repair.
- A kò nílò ìpara omi fún mọ́tò náà.

Image 6.1: Close-up of the spiral steel heating elements. Regular cleaning helps maintain efficiency and prolong heater life.
7. Laasigbotitusita
If your heater is not operating correctly, consult the following table before contacting customer support.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Alagbona ko ni tan-an. | Ko si ipese agbara. Bireki Circuit ti kọlu. Idaabobo igbona ti mu ṣiṣẹ. | Ensure heater is properly wired and connected to 240V supply. Ṣayẹwo ki o tun ẹrọ fifọ Circuit pada. Turn off heater, allow to cool for 30 minutes, then restart. Clear any obstructions. |
| Alagbona nmu ooru ti ko to. | Ipo ti ko tọ ti yan. Ṣeto iwọn otutu ju kekere. Iwọn yara naa ju agbara igbona lọ. | Ensure HIGH or ECO mode is selected, not FAN ONLY. Mu iwọn otutu ti a ṣeto pọ si. Verify the heater's coverage area (700 sq ft for 7500W) is appropriate for your space. |
| Fan gbalaye sugbon ko si ooru. | FAN ONLY mode selected. Heating elements malfunction. | Switch to ECO or HIGH heat mode. If problem persists, contact a qualified technician. |
| Isakoṣo latọna jijin ko ṣiṣẹ. | Awọn batiri ti o ku. Idilọwọ laarin isakoṣo latọna jijin ati igbona. | Rọpo awọn batiri isakoṣo latọna jijin. Ensure a clear line of sight to the heater's control panel. |

Image 7.1: Heating coverage chart for various KING garage heater wattages. The 7500W model covers up to 750 sq ft.
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Awoṣe | KB2407-1-B2-ECO |
| Brand | OBA |
| Wattage | 7500 Wattis |
| Voltage | 240 Volts |
| Ampigba | 31.25 Amps |
| Alapapo Ideri | Up to 700 ft² (based on 8 ft ceiling height and FHA standard insulation values) |
| Pataki Awọn ẹya ara ẹrọ | Remote Control, Built-In Fan Delay, Summer Fan Only & Timer Modes, ECO2S Electronic Thermostat |
| Iṣagbesori Iru | Universal Wall/Ceiling Bracket |
| Ọja Mefa | 13.5 x 15 x 16.5 inches |
| Iwọn Nkan | 33.5 iwon |
| UPC | 093319220405 |
9. Atilẹyin ọja ati Support
For warranty information or technical support, please refer to the warranty card included with your product or visit the manufacturer's official webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.
Manufacturer: King Electric
For further assistance, contact King Electric customer service.