Ọrọ Iṣaaju
The PC101 Water Quality Tester is designed for quick and accurate measurement of pH and Chlorine (CL2) levels in swimming pools, aquariums, and spas. This device provides instant readings, eliminating the need for complex color matching charts. It is an essential tool for maintaining optimal water quality.

Image: The PC101 Water Quality Tester, showing the main handheld unit, the separate probe with two electrodes, and the coiled cable connecting them.
Ṣeto
- Fifi sori batiri: The PC101 requires one (1) AA 1.5V Alkaline battery (not included). Open the battery compartment, insert the battery with correct polarity, and close the compartment securely.
- Asopọ Iwadi: Ensure the probe is securely connected to the main unit.
- Initial Adjustment (Chlorine): Before testing chlorine levels, the meter must be adjusted to the "adjustment point." Refer to the operating instructions for detailed steps on this calibration.
Awọn ilana Iṣiṣẹ
General Usage Notes:
- Do not immerse the probe in any liquid other than pool or spa water.
- Always ensure the probe is clean before and after use.
Testing Chlorine (CL2) Level:
- Igbaradi: Ensure the unit is powered on and the probe is clean.
- Atunṣe: Before each chlorine test, adjust the meter to the "adjustment point" as indicated on the device. This typically involves placing the probe in a known solution or following a specific procedure outlined on the device itself (often a dial or switch).
- Ibọmi: Carefully immerse the probe into the water you wish to test (pool, spa, aquarium).
- Kika: Wait for the reading to stabilize on the large screen. The safe measure range for Chlorine Level is 1.2 to 1.7 ppm.
Testing pH Level:
- Igbaradi: Ensure the unit is powered on and the probe is clean.
- Ibọmi: Carefully immerse the probe into the water you wish to test.
- Kika: Wait for the reading to stabilize on the large screen. The safe measure range for pH Level is 7.2 to 7.8.

Aworan: A sunmọ-soke view of the PC101 tester's display, showing the analog scales for pH and Chlorine levels with color-coded indicators for ideal ranges.
Itoju
- Ṣiṣe ayẹwo naa: After each use, gently rinse the probe with clean water and wipe it dry with a soft cloth. Do not use abrasive materials or harsh chemicals.
- Ibi ipamọ: Store the PC101 tester in a dry, cool place, away from direct sunlight and extreme temperatures. Ensure the probe is protected from damage.
- Rirọpo Batiri: If the display becomes dim or readings are inconsistent, replace the AA 1.5V battery.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ko si ifihan tabi baibai àpapọ | Kekere tabi okú batiri | Replace the 1.5V AA battery. |
| Inaccurate Chlorine readings | Meter not adjusted to "adjustment point" before testing | Ensure the meter is adjusted correctly before each chlorine test. |
| Awọn kika ti ko ni ibamu | Dirty probe electrodes; Battery low | Clean the probe electrodes thoroughly; Replace battery. |
| Ṣewadii ibajẹ | Physical damage or immersion in non-pool/spa liquids | Avoid immersing the probe in liquids other than pool/spa water. Handle with care. Replacement probe may be required. |
Awọn pato
- Awoṣe: PC101
- Chlorine Level Safety Range: 1.2 si 1.7 ppm
- pH Level Safety Range: 7.2 si 7.8
- Ibi ti ina elekitiriki ti nwa: 1 x AA 1.5V Alkaline Battery (not included)
- Awọn Iwọn Ẹka Akọkọ: Isunmọ 190 x 120 mm
- Probe with Handle Length: 150 mm
- Probe (electrode part only) Length: 48 mm (excluding black band)
- Gigun USB: 130 mm
- Awọn ẹya ara ẹrọ Ifihan: Ailokun
Atilẹyin ọja ati Support
No specific warranty or support information is provided with this product. For any issues, please refer to the troubleshooting section or contact your retailer.