This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodyear Pneumatic Oil Transfer Pump, Model OP-123. Please read this manual thoroughly before using the pump to ensure proper function and to prevent injury or damage.

Goodyear Pneumatic Oil Transfer Pump, Model OP-123

Figure 1: Goodyear Pneumatic Oil Transfer Pump, Model OP-123. This image displays the main unit of the pump, highlighting its robust construction and pneumatic input.

2. Alaye Aabo

Adherence to safety guidelines is paramount when operating pneumatic equipment. Failure to follow these instructions may result in serious injury or equipment damage.

3. Eto ati fifi sori

Follow these steps for proper setup and installation of your oil transfer pump.

  1. Ṣii silẹ: Fi ìṣọ́ra yọ gbogbo àwọn ohun èlò kúrò nínú àpótí náà. Ṣàyẹ̀wò bóyá àwọn àmì ìbàjẹ́ bá wáyé nígbà tí o bá ń gbé ibẹ̀.
  2. Bung Adapter Installation: The pump includes a 2-inch adjustable bung adapter for easy installation on standard drums. Thread the lower part of the adapter into the drum's bung opening, then tighten the upper part to secure the pump at the desired height.
  3. Tube gbigba: The pump's pickup tube may require an extension to reach the bottom of certain drums (e.g., 55-gallon drums). An extension kit is sold separately. Ensure the pickup tube is fully submerged in the fluid for optimal performance.
  4. Awọn aṣayan iṣagbesori:
    • Barrel Mount: Utilize the integrated bung adapter for direct mounting onto a fluid drum.
    • Cart Mount: The pump can be mounted onto a transfer cart for mobility.
    • Odi Odi: A wall mount kit is available separately for fixed installations.
  5. Asopọmọra Atẹgun: Connect your clean, dry, and regulated air supply hose to the 1/4-inch air inlet connection on the pump. Ensure a secure, leak-free connection.
  6. Oil Outlet Connection: Connect the fluid transfer hose to the 1/2-inch male oil outlet connection. Ensure all connections are tight to prevent leaks.
Diagram of Goodyear Oil Transfer Pump components

Figure 2: Diagram illustrating the key components of the Goodyear Oil Transfer Pump, including the air pressured motor, silencer, bung adapter, aluminum tube, and oil filter.

4. Isẹ

Once the pump is properly installed and all connections are secure, follow these steps to operate the pump.

  1. Verify Fluid Type: Confirm that the fluid to be transferred is compatible with the pump and within the recommended viscosity range (up to SAE130). Typical fluids include motor oil, gear oil, hydraulic oil, and automatic transmission fluid.
  2. So Afẹfẹ Ipese pọ: Connect the regulated air supply to the pump's air inlet. Ensure the air pressure is set between 70-115 PSI (5-8 bar).
  3. Initiate Pumping: Open the air valve to begin the transfer process. The pump is double-acting and self-priming, designed for rapid and precise flow rates.
  4. Abojuto Isẹ: Observe the fluid transfer. The pump has a maximum flow rate of 3.2 GPM (12 LPM).
  5. Paade: Once the desired amount of fluid has been transferred, close the air valve to stop the pump.
  6. Ipa Tu silẹ: Before disconnecting any hoses, ensure all residual pressure in the fluid line is safely released.
Goodyear pump transferring various oils from a drum

Figure 3: The Goodyear pump shown in operation, illustrating its capability to transfer typical oils such as motor oil, gear oil, automatic transmission fluid, and SAE 30 from a drum.

5. Itọju

Regular maintenance ensures the longevity and optimal performance of your Goodyear pump.

6. Laasigbotitusita

Tọkasi apakan yii fun awọn ọran ti o wọpọ ati awọn solusan ti o pọju wọn.

IsoroOwun to le FaOjutu
Pump not operating or low flow rate
  • Titẹ afẹfẹ ti ko to
  • Ipese afẹfẹ ko sopọ
  • Air line blockage or leak
  • Fluid too viscous
  • Pickup tube not submerged or blocked
  • Check and adjust air pressure to 70-115 PSI.
  • Ensure air supply is securely connected.
  • Inspect air lines for damage or blockages.
  • Verify fluid compatibility and viscosity.
  • Ensure pickup tube is fully submerged and clear of obstructions.
Fluid leaks from connections
  • Awọn ohun elo alaimuṣinṣin
  • Ti bajẹ edidi tabi Eyin-oruka
  • Tighten all fluid connections.
  • Inspect and replace any damaged seals or O-rings.
Pump not reaching bottom of drum
  • Standard pickup tube length is insufficient for drum depth.
  • An extension tube kit is available separately to increase the reach of the pickup tube.

7. Awọn pato

Detailed technical specifications for the Goodyear Pneumatic Oil Transfer Pump.

Technical specifications for Goodyear Oil Transfer Pump

Figure 4: Visual representation of key technical specifications including flow rate, pump life, and maximum viscosity.

SipesifikesonuIye
Nọmba awoṣeOP-123
Olupese Apá Number1701031G-UK
Oṣuwọn Sisan (O pọju)3.2 GPM / 12 LPM
Pressure Ratio (Max)3:1
Air Input Pressure (Max)5-8 igi / 70-115 PSI
Liquid Pressure (Max)8 igi / 115 PSI
Afẹfẹ Motor Opin63 mm / 2.5 inches
Air Consumption (@ 8BAR / 115PSI)110L / 3.9 CFM
Air Inlet Asopọ1/4 inch
Oil Outlet Connection1/2 inch male
Pump Life (Approx.)360k liters / 95k+ gallons
Irisi ti o pọjuSAE130
Ohun eloAluminiomu
Awọn iwọn Ọja (L x W x H)12.95 x 12.95 x 61.98 cm
Iwọn Ọja3.8 kg
Universal FitBẹẹni
Automotive Service TypeTruck, Tractor

8. Atilẹyin ọja ati Support

Ìwífún nípa àtìlẹ́yìn ọjà àti ìrànlọ́wọ́ oníbàárà kò sí nínú dátà ọjà tí a pèsè. Jọ̀wọ́ tọ́ka sí àpótí ọjà náà tàbí ilé iṣẹ́ olùpèsè. webojú òpó wẹ́ẹ̀bù fún àwọn àlàyé lórí ààbò àtìlẹ́yìn àti bí a ṣe lè kàn sí ìrànlọ́wọ́ àwọn oníbàárà.

Awọn iwe aṣẹ ti o jọmọ - OP-123

Ṣaajuview Goodyear Digital Oil Control Valve Instruction Manual
Comprehensive instruction manual for the Goodyear Digital Oil Control Valve (Model 18123522G), covering technical details, safety precautions, installation, operation, troubleshooting, and warranty information.
Ṣaajuview Goodyear GY09ATK - Manual del Martillo Neumático
Manual de usuario completo para el kit de martillo neumático Goodyear GY09ATK. Incluye guías esenciales para un funcionamiento seguro, montaje, mantenimiento y solución de problemas. Asegure el rendimiento óptimo y la longevidad de su herramienta.
Ṣaajuview Goodyear Blimp Ride-On Toy Assembly and Safety Instructions
Comprehensive assembly instructions and safety guidelines for the Goodyear Blimp ride-on toy, suitable for children aged 12+ months. Includes parts list, step-by-step assembly, and battery handling information.
Ṣaajuview Ìwé Ìtọ́sọ́nà fún Ìrìn Àjò Kébù Onímọ̀ṣẹ́ Goodyear
Instruction manual for the Goodyear Professional Cable Reel, covering safety regulations, technical details, installation, operation, maintenance, troubleshooting, and warranty information. Includes model numbers 63313134G, 63313132G, and 63313156G.
Ṣaajuview Afowoyi de Usuario Compresor de Aire Goodyear GY2248CD/GY2508CD Series
Guía completa de usuario para los compresores de aire Goodyear modelos GY2248CD, GY2248CDS, GY2248CDH, GY2508CD, GY2508CDS, GY2508CDH. Incluye instrucciones de seguridad, montaje, operación, mantenimiento y solución de problemas.
Ṣaajuview Goodyear Irin Orisun omi Ìṣó Reel Ilana Afowoyi
Itọsọna itọnisọna yii n pese alaye alaye lori iṣẹ ailewu, fifi sori ẹrọ, ati itọju Goodyear Steel Spring Driven Reels, pẹlu awọn awoṣe L820153G, L820154G, M820154G, ati H820152G. O ni wiwa awọn ilana aabo gbogbogbo, awọn alaye imọ-ẹrọ, awọn ilana fifi sori ẹrọ, awọn itọnisọna iṣẹ, ati awọn atokọ apakan.