1. Ifihan
The Aqua Control C1114 Automatic Garden Irrigation Programmer is designed to automate your garden's watering system, managing up to 4 independent irrigation zones. This programmer ensures efficient water distribution by allowing precise control over watering schedules, durations, and frequencies. It features an intuitive LCD display and a rotary dial for easy programming.

2. Awọn ẹya Ọja
- Iṣakoso Agbegbe Pupọ: Manages up to 4 independent irrigation zones.
- Ṣíṣe ètò tó rọrùn: Offers two independent programs (A and B), each with up to 4 start times.
- Àkókò Tí A Lè Ṣàtúnṣe: Watering duration can be set from 1 minute to 240 minutes (4 hours).
- Awọn aṣayan Igbohunsafẹfẹ: Program by specific days of the week, every 'x' days, or odd/even days.
- Iṣẹ́ Ìdádúró Òjò: Temporarily suspends watering for 0, 24, 48, or 72 hours due to rain or other factors.
- Rain Sensor Compatibility: Connect an external rain sensor to automatically stop watering on rainy days.
- Master Valve/Pump Start: Includes a connection for a pump or master valve.
- Ni wiwo olumulo-ore: Large LCD display and intuitive rotary dial for easy programming and monitoring.
- Aṣayan fifun omi pẹlu ọwọ: Allows for immediate, unscheduled watering.
3. Eto ati fifi sori
3.1 Ipese Agbara
The programmer requires a 230 VAC, 50 Hz input transformer (included) which outputs 24 VAC, 0.650A. Additionally, 2 AA alkaline batteries (not included) are required for memory backup and display operation during power outages.
3.2 Awọn isopọ onirin
Open the battery compartment cover to access the wiring terminals. Connect your solenoid valves, master valve (if applicable), and rain sensor to the appropriate terminals as indicated on the unit.
- 24VAC: Connect the transformer output.
- SENSER: Connect an optional rain sensor.
- C (Common): Connect the common wire from all solenoid valves.
- M (Master Valve): Connect the master valve, if used.
- 1, 2, 3, 4: Connect individual zone solenoid valves.

3.3 Iṣagbesori
Mount the programmer in a sheltered location, away from direct sunlight and extreme weather conditions, using appropriate fasteners through the mounting holes provided.
4. Awọn ilana Iṣiṣẹ
The Aqua Control C1114 features a rotary dial and several buttons for easy navigation and programming. Refer to Figure 3 for a visual guide to the control panel.

4.1 Iṣakoso igbimo Loriview
- Ifihan LCD: Shows current time, program settings, and status.
- Ipe ipe Rotari: Used to select programming modes (SET CLOCK, START TIME, HOW LONG, HOW OFTEN, ON, OFF).
- Bọtini Afọwọṣe: Initiates manual watering.
- PROG A/B Button: Toggles between Program A and Program B.
- Tẹ Bọtini: Jẹrisi awọn aṣayan ati eto.
- < / > Buttons: Navigate between parameters or adjust values.
- +/- Awọn bọtini: Increase or decrease numerical values.
- RAIN DELAY Button: Activates or adjusts the rain delay function.
- Bọtini MO: Clears current settings or inputs.
- Bọtini Tuntun: Resets all programming to factory defaults (located under the dial).
4.2 Initial Setup: Setting Current Time and Date
- Yi ipe kiakia Rotari si ṢEto aago.
- Lo awọn + or - buttons to set the current hour. Press WOLE.
- Set the current minute. Press WOLE.
- Set the current day of the week. Press WOLE.
- Tan ipe naa si ON to save settings and return to normal operation.
4.3 Programming Irrigation Schedules (Program A/B)
The programmer allows for two independent programs, A and B. Each program can have up to 4 start times.
- Tẹ awọn PROG A/B button to select either Program A or Program B. The selected program will be displayed on the LCD.
- Yi ipe kiakia Rotari si AKOKO BERE.
- Lo + or - to set the first start time. Press WOLE.
- Repeat for up to 4 start times. If fewer than 4 are needed, press WOLE to skip remaining start times.
- Yi ipe kiakia Rotari si BAWO LO SE GUN TO.
- Lo + or - to set the watering duration for each zone (from 1 to 240 minutes). Use the < or > buttons to select the zone (1-4) you wish to set. Press WOLE after setting each zone's duration.
- Yi ipe kiakia Rotari si BAWO NI O ṢE N WAYE SI.
- Select the watering frequency:
- Àwọn Ọjọ́ Pàtàkì: Lo < or > to select days of the week (e.g., MO, TU, WE). Press WOLE lati yan/fi yan.
- Every X Days: Select this option and use + or - lati ṣeto aarin (fun apẹẹrẹ, ni gbogbo ọjọ 2).
- Àwọn Ọjọ́ Àìdọ́gba/Àkókò Kan: Select to water on odd or even calendar days.
- Tan ipe naa si ON to activate the program.
4.4 Afowoyi agbe
To initiate manual watering:
- Ensure the rotary dial is set to ON.
- Tẹ awọn Afọwọṣe bọtini.
- Lo + or - lati ṣeto awọn ti o fẹ Afowoyi agbe iye.
- Tẹ WOLE lati bẹrẹ agbe ọwọ. Ifihan naa yoo fihan akoko to ku.
- Lati da agbe afọwọyi duro, tẹ KỌRỌ tabi yi ipe kiakia si PAA ati lẹhinna pada si ON.
4.5 Iṣẹ́ Ìdádúró Òjò
To temporarily suspend watering:
- Ensure the rotary dial is set to ON.
- Tẹ awọn ÌDÚRÙN ÒJÒ bọtini.
- Lo + or - to select the delay duration (0, 24, 48, or 72 hours).
- Tẹ WOLE to activate the rain delay. The display will show the remaining delay time.
- To cancel the rain delay, press ÌDÚRÙN ÒJÒ again and set the duration to 0, then press WOLE.
4.6 Turning Off the Programmer
To completely stop all automatic watering, turn the rotary dial to PAA. To resume, turn the dial back to ON.
5. Itọju
- Ninu: Mu ese kuro pẹlu rirọ, damp asọ. Ma ṣe lo awọn olutọpa abrasive tabi fi omi mọlẹ kuro ninu omi.
- Rirọpo Batiri: Replace the 2 AA alkaline batteries annually or when the low battery indicator appears on the LCD to ensure program memory retention during power outages.
- Igba otutu: In freezing climates, disconnect the programmer from the power supply and remove it from its outdoor location. Store it indoors in a dry, frost-free environment.
6. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Programmer display is blank. | No power from transformer; dead AA batteries. | Check transformer connection and power outlet. Replace AA batteries. |
| Zones are not watering. | Programmer is OFF; Rain Delay active; wiring issue; solenoid valve malfunction. | Ensure dial is on ON. Check Rain Delay status. Verify wiring connections. Test solenoid valves. |
| Watering occurs at incorrect times. | Incorrect current time/date; incorrect program start times. | Re-set current time and day. Review and adjust program start times. |
| Programmer resets unexpectedly. | Power interruption; low AA batteries. | Ensure stable power supply. Replace AA batteries. |
7. Awọn pato
- Awoṣe: C1114
- Awọn agbegbe: Up to 4 independent zones
- Input Oluyipada: 230 VAC, 50 Hz
- Iyipada Transformer: 24 VAC, 0.650A
- Output per Station: 24 VAC, 15.6 VA
- Master Valve Output: 24 VAC, 15.6 VA
- Ibeere Batiri: 2 x AA Alkaline batteries (not included)
- Programming Duration: Iṣẹju 1 si iṣẹju 240 (wakati 4)
- Idaabobo Apọju: Bẹẹni
- Ìwọ̀n Nkan: Nǹkan bí 500 Giramu
- Olupese: Aqua Control
8. Atilẹyin ọja ati Support
For warranty information or technical support, please contact Aqua Control customer service. Refer to the product packaging or the official Aqua Control webaaye fun awọn alaye olubasọrọ.