1. Ifihan
The DAB E.SYBOX is an integrated electronic water booster system designed for domestic and residential applications. This system provides constant water pressure while optimizing energy consumption. It is suitable for use with potable water in domestic plants, for gardening, and irrigation. The E.SYBOX can also be used to create groups of up to four pumps.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your E.SYBOX system. Please read it thoroughly before installation and keep it for future reference.
2. Alaye Aabo
WARNING: Before performing any operation on the pump, disconnect it from the main power supply.
- Rii daju pe ipese agbara voltage matches the specifications of the E.SYBOX (230V).
- Fifi sori ẹrọ ati itọju yẹ ki o ṣe nipasẹ oṣiṣẹ ti o peye nikan.
- Do not operate the pump with flammable or explosive liquids.
- Dabobo ẹrọ naa lati awọn iwọn otutu didi.
- Rii daju pe fentilesonu to dara ni ayika ẹyọ naa lati ṣe idiwọ igbona.
- Ẹyọ naa gbọdọ wa ni ilẹ daradara.
3. Package Awọn akoonu
Daju pe gbogbo awọn paati wa ati pe ko bajẹ lori ṣiṣi silẹ:
- DAB E.SYBOX Water Booster System Unit
- Okun agbara
- Connection Pieces (e.g., 1" plastic unions)
- Afowoyi Olumulo (iwe-ipamọ yii)
4. Eto ati fifi sori
The E.SYBOX is designed for straightforward installation and requires no additional components for basic setup. It can be installed either vertically or horizontally.
4.1. Yiyan ipo fifi sori ẹrọ
Select a location that is:
- Protected from direct sunlight and extreme temperatures.
- In a closed space without a high level of air exchange, as the unit is water-cooled and quiet.
- Wiwọle fun itọju.
- Near the water source and the distribution system.
4.2. Fifi sori ti ara
- Gbigbe Ẹka naa: Place the E.SYBOX on a stable, level surface. The anti-vibration feet help reduce noise. The unit can be positioned vertically or horizontally.
- Nsopọ awọn Laini Omi: Connect the inlet pipe from your water source to the suction port and the outlet pipe to your distribution system. Use the provided 1" plastic unions for secure connections. Ensure all connections are watertight.
- Asopọmọra itanna: Connect the power cord to a grounded 230V AC outlet. Ensure the power supply is stable and protected from surges.
- Priming the Pump (if necessary): For initial startup or after maintenance, ensure the pump is filled with water before operation to prevent dry running. Refer to the display for priming instructions.

olusin 1: Iwaju view of the DAB E.SYBOX unit, showing the display and general form factor.

olusin 2: Ẹyìn view of the E.SYBOX, highlighting the water inlet and outlet connections.
5. Awọn ilana Iṣiṣẹ
The E.SYBOX features an adjustable, high-resolution LCD display for easy operation and monitoring.
5.1. Ibẹrẹ Agbara-On
- Once connected to power, the LCD display will illuminate.
- Follow the on-screen prompts for initial setup, which may include language selection and basic pressure settings.
5.2. Setting Desired Pressure
The E.SYBOX allows you to set your desired water pressure. The system will then maintain this constant pressure by adjusting pump speed.
- Navigate through the LCD menu using the control buttons adjacent to the display.
- Locate the "Pressure Setting" option.
- Adjust the pressure value (e.g., in PSI or Bar) to your preference. The system can deliver up to 210 ft (approx. 90 PSI) of head.
- Confirm your selection. The system will automatically adjust to maintain this pressure.

Figure 3: E.SYBOX display showing operational parameters such as power consumption (360W), pressure (3 Bar / 43 PSI), and flow rate (3.2 GPM / 12 l/min).
5.3. Mimojuto Performance
The LCD display provides real-time statistics:
- Titẹ: Current system pressure.
- Oṣuwọn Sisan: Instantaneous water flow.
- Lilo agbara: Energy consumption of the unit.
- Awọn itaniji/Ikilọ: Notifications for any operational issues.
6. Itọju
Regular maintenance ensures the longevity and optimal performance of your E.SYBOX system.
6.1. Àwọn Àyẹ̀wò Àṣàrò
- Ayewo wiwo: Periodically check for any leaks, unusual noises, or visible damage.
- Air Exchange: Ensure the area around the unit is not obstructed to allow for proper air circulation for the water-cooled motor.
6.2. Sensọ Cleaning
Over time, sediment may accumulate and affect the flow sensors. The E.SYBOX comes with a tool for cleaning these sensors.
- Ge Agbara: Always disconnect the unit from the power supply before any maintenance.
- Locate Sensors: Refer to the detailed diagram in the full technical manual (if available) to locate the flow sensors.
- Mọ: Use the provided tool to carefully clean any accumulated sediment from the sensors.
- Tun sopọ: Reassemble any removed parts and reconnect power.
6.3. Igba otutu
If the unit is installed in an area subject to freezing temperatures, it must be drained to prevent damage.
- Ge asopọ agbara.
- Drain all water from the pump and associated piping.
- Store in a frost-free environment if possible, or ensure complete drainage.
7. Laasigbotitusita
This section addresses common issues you might encounter with your E.SYBOX system.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| No water flow / Pump not starting | No power; Air in pump; Clogged inlet; Low water level in source. | Check power connection; Prime the pump; Clean inlet filter; Ensure adequate water supply. |
| Iwọn kekere | Incorrect pressure setting; Partially clogged filter/pipes; Air in system. | Adjust pressure setting on LCD; Inspect and clean filters/pipes; Bleed air from system. |
| Pump runs continuously / Frequent on/off cycling | Leak in system; Small continuous flow (e.g., dripping faucet); Faulty sensor. | Check for leaks in plumbing; Address small continuous flows; Contact support if sensor is suspected. |
| Ariwo dani tabi gbigbọn | Air in pump; Loose connections; Foreign object in pump. | Prime the pump; Check and tighten all connections; Disconnect power and inspect pump impeller (if safe and accessible). |
| LCD display error message | Aṣiṣe eto pato. | Note the error code and consult the full technical manual or contact customer support. |
Ti iṣoro naa ba wa lẹhin igbiyanju awọn iṣeduro wọnyi, jọwọ kan si atilẹyin alabara.
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Awoṣe | 60161182 |
| Voltage | 230 Volts |
| Orisun agbara | AC/DC |
| Oṣuwọn Sisan ti o pọju | 32 Galonu fun iseju kan (GPM) |
| Giga Igbega ti o pọju (Ori) | 210 Ẹsẹ |
| Liquid otutu Range | +32 to +95°F (domestic use), +32 to +102°F (other uses) |
| O pọju afamora Ijinle | 26 Ẹsẹ |
| Iwọn Nkan | 57 iwon |
| Awọn iwọn Ọja (L x W x H) | 14.25 x 10.35 x 22.2 inches |
| Ohun elo | ABS |
| Integrated Expansion Tank | 0.5 galonu |
9. Atilẹyin ọja ati Support
9.1. atilẹyin ọja Information
DAB provides a limited warranty for the E.SYBOX 230V Water Booster System against defects in materials and workmanship under normal use and service. The specific duration and terms of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.
For detailed warranty terms and conditions, refer to the warranty card included with your product or visit the official DAB webojula.
9.2. Onibara Support
If you require technical assistance, have questions about installation, operation, or maintenance, or need to report a problem, please contact DAB customer support.
- Atilẹyin Ayelujara: Visit the official DAB Pumps website for FAQs, technical documents, and contact forms.
- Atilẹyin foonu: Refer to the contact information provided on the DAB website or your product packaging for regional support numbers.
- When contacting support, please have your product model (60161182) and serial number (if applicable) ready.