1. Ifihan
1.1 Ọja Loriview
The Astral Pool Victoria Plus Silent pump, model 65562, is a high-performance, self-priming filtration pump designed for swimming pools. Engineered with thermoplastic materials, this pump offers enhanced durability and protection. Its design focuses on ease of use and maintenance, while operating at a reduced noise level, typically between 61 dBA and 70 dBA. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your pump.

olusin 1: Apa view of the Astral Pool Victoria Plus Silent pump.
1.2 Abo Alaye
Before installing, operating, or performing maintenance on this pump, please read and understand all safety instructions. Failure to follow these instructions could result in serious injury or property damage.
- Aabo Itanna: Always disconnect power to the pump before servicing. Electrical work should only be performed by a qualified electrician.
- Aabo omi: Ensure proper water flow and avoid running the pump dry, as this can cause damage.
- Aabo Kemikali: Be aware of pool chemicals and their interaction with pump components.
- Awọn ọmọde: Pa awọn ọmọde kuro ni fifa soke ati awọn asopọ itanna.
2. Eto ati fifi sori
2.1 Pump Placement
Position the pump on a solid, level surface, as close to the pool as possible to minimize friction losses in the suction line. Ensure adequate ventilation around the pump for cooling and easy access for maintenance.
2.2 Plumbing Awọn isopọ
Connect the pump to your pool's filtration system using appropriate plumbing fittings. Ensure all connections are watertight to prevent leaks and maintain prime. Use thread sealant on all threaded connections.
2.3 Itanna Asopọ
This pump operates on 230V single-phase power. All electrical wiring must comply with local codes and regulations and should be performed by a licensed electrician. Ensure the pump is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD).
3. Awọn ilana Iṣiṣẹ
3.1 Priming fifa soke
Before initial startup or after the pump has been drained, it must be primed. Open the pre-filter lid, fill the basket with water until it overflows, then replace the lid securely. Ensure all valves are open to allow water flow from the pool to the pump.
3.2 Bibẹrẹ fifa
Once primed, turn on the power to the pump. The pump should start drawing water and expel air from the system. If the pump does not prime within a few minutes, turn it off, re-prime, and check for air leaks in the suction line.
3.3 Ojoojumọ Isẹ
Operate the pump for a sufficient duration each day to ensure proper filtration of your pool water. The exact duration depends on pool size, bather load, and environmental conditions. Consult your pool professional for recommended run times.
4. Itọju
4.1 Cleaning the Pre-Filter Basket
Regularly inspect and clean the pre-filter basket to remove debris. A clogged basket reduces pump efficiency and can lead to damage.
- Pa fifa naa ki o si ge agbara kuro.
- Close any necessary valves to prevent water flow from the pool.
- Unscrew the pre-filter lid.
- Yọ apẹ̀rẹ̀ náà kúrò kí o sì kó gbogbo ìdọ̀tí náà dà nù.
- Fi omi ṣan agbọn naa daradara.
- Inspect the lid O-ring for damage and lubricate if necessary.
- Replace the basket and secure the lid tightly.
- Re-prime the pump if necessary before restarting.

olusin 2: Top view showing the pre-filter lid for cleaning access.
4.2 Igba otutu
In regions subject to freezing temperatures, the pump must be properly winterized to prevent damage. Drain all water from the pump and plumbing lines. Store the pump in a dry, frost-free location if possible, or follow manufacturer guidelines for in-place winterization.
5. Laasigbotitusita
This section addresses common issues you might encounter with your pump. For problems not listed here, or if solutions do not resolve the issue, contact a qualified service technician.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ | Kò sí agbára; ẹ̀rọ ìdènà tí ó bàjẹ́; ìṣòro mọ́tò | Check power supply, reset breaker; consult electrician. |
| Pump runs but does not prime or loses prime | Low water level; air leak in suction line; clogged pre-filter; closed valve | Check pool water level; inspect suction line for leaks; clean pre-filter basket; ensure all valves are open. |
| Dinku sisan oṣuwọn | Clogged pre-filter; dirty main filter; restricted plumbing | Clean pre-filter basket; backwash or clean main filter; check plumbing for obstructions. |
| Ariwo pupọ tabi gbigbọn | Air leak; cavitation; worn bearings; loose mounting | Check for air leaks; ensure proper water flow; contact service for worn parts; tighten mounting bolts. |
6. Awọn pato
Technical data for the Astral Pool Victoria Plus Silent 1 CV Single-Phase Filtration Pump, Model 65562:
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | Astralpool |
| Nọmba awoṣe | 65562 |
| Voltage (V) | 230 |
| Agbara (CV) | 1 |
| Capacity (l/h) | 16,000 |
| Nominal Flow Rate (m³/h) | 16 |
| Ohun elo | Plastic (Thermoplastic) |
| Package Mefa | 69 x 40 x 28 cm |
| Iwọn Nkan | 10 kg (22.05 lbs) |
| Orisun agbara | AC Electric |
7. Atilẹyin ọja ati Support
Specific warranty details for the Astral Pool 65562 Victoria Plus Silent pump are not provided in this manual. For warranty information, please refer to the documentation included with your purchase or contact Astral Pool directly or your authorized dealer. For technical support or spare parts, please reach out to your supplier or an authorized service center.