This manual provides essential information for the installation, operation, and maintenance of your Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the appliance.
The Vaillant ECOTEC PURE VMW 246/7-2 is a methane-powered condensing boiler designed for both central heating and instantaneous domestic hot water production. It features an intuitive user interface, a high-efficiency modulating pump, and a durable primary steel exchanger.

Nọmba 1: Iwaju view of the Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. The unit is white with the Vaillant logo prominently displayed. A digital display shows '50' and control buttons are visible below it.
2. Awọn ilana aabo
Pataki: Failure to follow these safety instructions could result in property damage, personal injury, or death. Keep this manual in a safe place for future reference.
- Installation and maintenance must only be carried out by a qualified and certified technician in accordance with local regulations and standards.
- Má ṣe kó àwọn ohun èlò tó lè jóná síbi ìgbóná omi náà.
- Ensure adequate ventilation in the room where the boiler is installed.
- If you smell gas, immediately shut off the gas supply, open windows and doors, and contact a qualified technician. Do not operate any electrical switches.
- Maṣe tamper with the boiler's internal components.
- Jeki awọn ọmọde ati awọn ohun ọsin kuro ninu ohun elo naa.
3. Fifi sori ẹrọ ati Oṣo
3.1 Pre-Fifi sọwedowo
- Verify that the gas supply type (methane) matches the boiler's requirements.
- Ensure the installation site meets all local building codes and ventilation requirements.
- Confirm that the electrical supply is compatible with the boiler's specifications.
- Unpack the boiler carefully and inspect for any shipping damage.
3.2 Mounting the Boiler
- Select a suitable wall location capable of supporting the boiler's weight (approximately 20 kg).
- Use the provided mounting template (if applicable) to mark drilling points for the wall bracket.
- Securely fasten the wall bracket to the wall using appropriate fixings.
- Carefully lift and hang the boiler onto the wall bracket.
3.3 Connecting Utilities
- Isopọ gaasi: Connect the methane gas supply line to the boiler's gas inlet, ensuring all connections are gas-tight and tested for leaks.
- Awọn isopọ omi: Connect the central heating flow and return pipes, and the domestic hot water inlet and outlet pipes. Ensure proper isolation valves are installed.
- Sisan omi Condensate: Connect the condensate drain line to an appropriate waste system, ensuring a continuous downward slope.
- Ètò Fífẹ́: Install the flue system according to manufacturer instructions and local regulations for safe exhaust gas discharge.
- Asopọmọra itanna: Connect the boiler to the electrical supply, ensuring proper grounding and circuit protection.
3.4 Initial Filling and Venting
- Fill the heating system with water to the recommended pressure (typically 1.0-1.5 bar), monitoring the pressure gauge.
- Vent all radiators and the boiler itself to remove air from the system.
- Check for any leaks in the entire system.
4. Awọn ilana Iṣiṣẹ
4.1 User Interface Loriview
The ECOTEC PURE VMW 246/7-2 features an intuitive user interface with a digital display and control buttons. The display shows current operating status, temperature settings, and error codes.
- Ifihan Digital: Shows temperature, pressure, and status codes.
- Bọtini Ipo: Toggles between heating, hot water, or standby modes.
- Awọn bọtini Iṣatunṣe iwọn otutu (+/-): Used to increase or decrease desired heating or hot water temperatures.
- Bọtini atunto: Used to clear certain error codes after rectifying the fault.
4.2 Bibẹrẹ igbomikana
- Ensure the gas supply is open and the electrical supply is connected.
- Check that the system pressure is within the recommended range (1.0-1.5 bar).
- Press the power button (if present) or ensure the boiler is switched on at the mains.
- Select the desired operating mode (e.g., heating and hot water).
- Set the desired heating and hot water temperatures using the adjustment buttons.
4.3 Connecting a VSMART Thermostat
The Vaillant ECOTEC PURE VMW 246/7-2 is compatible with the Vaillant VSMART thermostat for enhanced control and energy efficiency. Refer to the VSMART thermostat's separate instruction manual for detailed pairing and operation instructions.
5. Itọju
Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Vaillant boiler. Only qualified technicians should perform maintenance tasks.
5.1 Annual Servicing
- It is recommended to have your boiler serviced annually by a Vaillant-certified technician.
- Annual servicing includes checking combustion efficiency, gas pressure, safety devices, and cleaning internal components.
5.2 User Checks
- Titẹ Eto: Regularly check the system pressure on the boiler's display. If it falls below 1.0 bar, repressurize the system according to the instructions in Section 3.4 or consult a technician.
- Ayewo wiwo: Periodically inspect the boiler for any visible leaks, unusual noises, or changes in performance.
- Sisan omi Condensate: Ensure the condensate drain is clear and not blocked.
6. Laasigbotitusita
This section provides solutions to common issues. For complex problems or if an error persists, contact a qualified service technician.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ko si igbona tabi omi gbona | Itẹ agbara eto kekere, ko si ipese gaasi, agbara outage, thermostat setting too low. | Check system pressure and repressurize if needed. Ensure gas valve is open. Check electrical supply. Adjust thermostat settings. |
| Bọ́ílì tó ń ṣàfihàn kódì àṣìṣe kan | Various internal faults. | Note the error code and consult the full technical manual or contact a qualified technician. Try pressing the Reset button once. |
| Unusual noises from the boiler | Afẹ́fẹ́ nínú ètò náà, ìṣòro pípèsè omi, ìkórajọ àwọn nǹkan bíi líméǹtì. | Vent radiators. If noise persists, contact a qualified technician. |
| Omi jo | Loose connection, faulty component. | Immediately turn off the water supply to the boiler and contact a qualified technician. |
| Pilot light (if applicable) not igniting | No gas supply, ignition fault. | Check gas supply. If problem persists, contact a qualified technician. |
| Reduced hot water flow or temperature | Limescale buildup, faulty sensor, low water pressure. | Check water pressure. Contact a qualified technician for inspection and descaling if necessary. |
7. Imọ ni pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Awoṣe | ECOTEC PURE VMW 246/7-2 |
| Nọmba apakan | 0010019985 |
| Brand | Vaillant |
| Epo Iru | Methane (Gasi Adayeba) |
| Alapapo Jade | 24 kW |
| Domestic Hot Water Output | 28 kW (Instantaneous) |
| Pump Iru | Modulating 1:4 (Class A) |
| Primary Exchanger Material | Irin |
| Imugboroosi Vessel Agbara | 8 liters |
| Awọn iwọn (H x W x D) | 80 cm x 50 cm x 40 cm (isunmọ) |
| Iwọn | 20 kg |
| Agbara ṣiṣe Rating | A |
| Ibamu | VSMART Thermostat |
8. Atilẹyin ọja ati Support
8.1 atilẹyin ọja Alaye
Vaillant products are covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Vaillant webojula fun alaye alaye.
Akiyesi: Improper installation, unauthorized repairs, or failure to perform regular maintenance may void your warranty.
8.2 Imọ Support
For technical assistance, spare parts, or to schedule a service appointment, please contact your local Vaillant service center or authorized dealer. Contact details can typically be found on the Vaillant official webaaye tabi ninu iwe ọja rẹ.
When contacting support, please have your boiler's model number (VMW 246/7-2) and part number (0010019985) readily available.