Ọrọ Iṣaaju
This user manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of the JBC JTSE-2QA Digital Hot Air Rework Station. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
Ọja Pariview

Figure 1: The JBC JTSE-2QA Digital Hot Air Rework Station, featuring the main unit with digital display, the hot air tool, and its dedicated stand. This station is designed for precise and controlled hot air applications in electronics rework.
The JBC JTSE-2QA is a high-performance digital hot air rework station designed for professional electronics repair and assembly. It offers precise temperature control and airflow management, making it ideal for desoldering and soldering surface-mount components (SMD).
Awọn Itọsọna Aabo
Máa tẹ̀lé àwọn ìlànà ààbò wọ̀nyí nígbà gbogbo láti dènà ìpalára àti ìbàjẹ́ sí ẹ̀rọ náà:
- Ensure the station is connected to a properly grounded power outlet (230V).
- Do not touch the hot air nozzle or heated components directly. Use appropriate tools and allow components to cool.
- Operate the station in a well-ventilated area to dissipate fumes.
- Keep flammable materials away from the hot air stream.
- Disconnect the power cord before performing any maintenance or cleaning.
- Do not operate the station if the power cord or unit is damaged.
- This device is for professional use only. Keep out of reach of children.
Ṣeto
- Ṣii silẹ: Fi ìṣọ́ra yọ gbogbo àwọn ohun èlò kúrò nínú àpótí náà. Rí i dájú pé gbogbo àwọn ohun tí a kọ sí apá "Ohun tí ó wà nínú Àpótí" wà níbẹ̀.
- Ibi: Place the main unit on a stable, heat-resistant, and level surface. Ensure adequate clearance around the unit for ventilation.
- Connect Hot Air Tool: Connect the hot air tool's hose and electrical connector to the corresponding ports on the main unit. Ensure a secure connection.
- Connect Stand: Position the hot air tool stand near the main unit and place the hot air tool securely in its holder when not in use. The stand often includes a sensor to detect when the tool is placed, activating standby mode.
- Asopọ agbara: Plug the power cord into the main unit's power inlet, then connect it to a grounded 230V AC power outlet.
Awọn ilana Iṣiṣẹ
1. Agbara lori / Paa
Press the power button located on the front panel to turn the station on or off. The digital display will illuminate upon startup.
2. Setting Temperature and Airflow
Lo awọn bọtini lilọ kiri (+, -, OK) on the front panel to adjust the hot air temperature and airflow settings. The display shows the current and set values. The temperature range is typically 150°C to 450°C.
- Iwọn otutu: Adjust the desired hot air temperature for your application.
- Fife ategun: Control the air volume output from the nozzle. Start with lower airflow for delicate components and increase as needed.
3. Using the Hot Air Tool
When the hot air tool is removed from its stand, the heating element will activate and the station will begin to reach the set temperature. When returned to the stand, the station will enter standby mode, cooling down the tool to a safe temperature.
- Select the appropriate nozzle for your application.
- Maintain a safe distance between the nozzle and the component to avoid overheating.
- Move the hot air tool in a circular motion to ensure even heating.
Itoju
Regular maintenance ensures the longevity and optimal performance of your JBC JTSE-2QA station.
- Ninu: Yọ agbara kuro ki o to nu. Lo ohun elo rirọ, damp cloth to wipe down the exterior of the main unit and the hot air tool. Do not use abrasive cleaners or solvents.
- Itọju Nozzle: Periodically inspect the hot air nozzles for blockages or damage. Clean them as needed to ensure proper airflow.
- Asẹ afẹfẹ: Check and clean or replace the air filter (if applicable) according to the manufacturer's recommendations to maintain optimal airflow and prevent dust accumulation.
- Ibi ipamọ: Store the station in a clean, dry environment when not in use.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ibusọ ko ni agbara lori. | Kò sí ìpèsè agbára; okùn agbára tí ó dẹ̀. | Ṣayẹwo asopọ agbara; rii daju pe iṣan jẹ iṣẹ-ṣiṣe. |
| Hot air tool not heating. | Tool not properly connected; tool in stand (standby mode); faulty heating element. | Ensure tool is securely connected and removed from stand; contact support if element is faulty. |
| Afẹfẹ ti ko to. | Blocked nozzle; dirty air filter. | Clean or replace nozzle; check and clean/replace air filter. |
| Temperature fluctuations. | Sensor issue; unstable power supply. | Ensure stable power; contact support for sensor issues. |
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | JTSE-2QA |
| Olupese | JBC |
| Iṣagbewọle Voltage | 230 folti AC |
| Iwọn otutu | 150 - 450 °C (302 - 842 °F) |
| Awọn iwọn (L x W x H) | 474 x 368 x 195 cm |
| Iwọn Nkan | 4.1 Kilogram (4104 Giramu) |
| Awọn irinše to wa | Gbona Air Rework Station |
| Nọmba ti awọn ikanni | 1 |
Atilẹyin ọja ati Support
For warranty information, technical support, or service inquiries regarding your JBC JTSE-2QA Digital Hot Air Rework Station, please contact JBC customer service or visit their official webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira fun awọn iṣeduro atilẹyin ọja.
JBC Official Webojula: www.jbctools.com