The Apera Instruments PH800 Benchtop pH Meter is engineered for precise and reliable pH measurements in various water solutions, suitable for scientific research and quality control applications. This kit includes Apera’s PC-body 201T-F pH/Temperature Electrode, enabling quick and accurate pH readings with automatic temperature compensation.

Awọn ẹya pataki:

  • Quick and easy 1 to 3 points automatic calibration with a calibration guide, automatically recognizing 5 types of pH standards (7.00, 4.00, 10.01, 12.45, 1.68).
  • High-quality 201T-F pH/temperature combination electrode ensures stable and accurate measurements for general water solutions.
  • GLP data management with 500 groups of data storage and USB data output.
  • Electrode slope display between calibrations to monitor the health and performance of your pH electrode.
  • Large backlit LCD displays pH and temperature simultaneously, along with icons for stable readings and completed calibrations.
  • ORP (Redox) measurement mode available with an optional ORP electrode (sold separately).
  • IP54 splash-proof design for enhanced durability.

2. Package Awọn akoonu

The Apera Instruments PH800 Benchtop pH Meter Kit includes the following components:

  • PH800 Benchtop pH Mita
  • 201T-F pH/Temperature Electrode
  • Flexible Electrode Arm and Holder
  • Okun USB
  • PC-Link Software Flash Drive (for Windows-based systems only)
  • DC9V (120V) Power Adapter
  • Calibration Solutions: 3 bottles (7.00, 4.00, 10.01, 50ml each)

3. Ni ibẹrẹ Oṣo

Follow these steps to set up your PH800 Benchtop pH Meter for first use:

  1. Yọ awọn ohun elo kuro: Fi ìṣọ́ra yọ gbogbo àwọn ohun èlò kúrò nínú àpótí náà kí o sì ṣe àyẹ̀wò bóyá ó ti bàjẹ́.
  2. Assemble Electrode Holder: Attach the flexible electrode arm and holder to the meter base. Ensure it is securely fastened to provide stable support for the electrode.
  3. Connect pH Electrode: Plug the BNC connector of the 201T-F pH/Temperature Electrode into the corresponding BNC port on the back of the meter. Connect the temperature probe into the TEMP port.
  4. So agbara: Plug the DC9V power adapter into the meter's power input port and then into a standard electrical outlet.
  5. Asopọ USB ti o fẹ: If you plan to use the GLP data management features, connect the USB cable from the meter to your computer. Install the provided PC-Link software from the flash drive (Windows only).
Apera Instruments PH800 Benchtop pH Meter with electrode and beaker

Nọmba 3.1: The Apera Instruments PH800 Benchtop pH Meter fully assembled with the electrode in a beaker, demonstrating a typical setup for measurement.

Ẹyìn view of Apera PH800 pH meter showing connection ports

Nọmba 3.2: Ẹyìn view of the PH800 meter, highlighting the REF, pH/mV, TEMP, USB, and DC 9V connection ports for various probes and power.

Flexible electrode holder for Apera PH800 pH meter

Nọmba 3.3: Close-up of the flexible electrode holder, designed for easy positioning and secure support of the pH electrode during operation.

4. Awọn ilana Iṣiṣẹ

4.1. Agbara lori / Paa

Tẹ awọn AGBARA button (usually marked with a circle and vertical line icon) to turn the meter on or off. The large backlit LCD will illuminate upon startup.

Oke-isalẹ view of Apera PH800 pH meter control panel

Nọmba 4.1: Oke-isalẹ view of the PH800 meter's control panel, showing the power button, mode/setup, enter, unit, calibration, and measurement buttons.

4.2. Iṣatunṣe

Accurate calibration is crucial for reliable pH measurements. The PH800 supports 1 to 3 points automatic calibration.

  1. Prepare Buffer Solutions: Use fresh Apera calibration solutions (pH 7.00, 4.00, 10.01 are commonly included). Ensure the electrode and beakers are clean.
  2. Bẹ̀rẹ̀ Ìṣàtúnṣe: Tẹ awọn CAL button. The meter will enter calibration mode.
  3. First Point Calibration: Rinse the electrode with distilled water and immerse it in the pH 7.00 buffer solution. Stir gently and wait for the reading to stabilize. The meter will automatically recognize the buffer and confirm calibration.
  4. Second and Third Point Calibration (Optional): For higher accuracy, repeat the process with pH 4.00 and pH 10.01 buffer solutions. The meter will guide you through the process.
  5. Calibration Reminder: The meter features a calibration reminder function to ensure regular calibration for optimal performance.
  6. Ipo elekitirodu: The self-diagnosis function provides slope data between calibration points, allowing you to monitor the condition and performance of your pH electrode.

4.3. Wiwọn

After successful calibration, you can proceed with measurements.

  1. Fi omi ṣan elekitirodu: Rinse the electrode thoroughly with distilled water before and after each measurement.
  2. Ẹ̀rọ ìtẹ̀mọ́lẹ̀: Fi elekitirodu sinu sample solution. Ensure the sensing part of the electrode is fully submerged.
  3. Duro fun Iduroṣinṣin: Allow the reading on the large backlit LCD to stabilize. A stable reading icon (often a smiley face) will appear when the measurement is ready. The display shows both pH and temperature simultaneously.
  4. Record Reading: Note down the pH and temperature values.
Apera PH800 pH meter large backlit screen displaying pH and temperature

Nọmba 4.4: The large backlit LCD screen of the PH800 meter, clearly displaying pH and temperature readings, along with stabilization and calibration success icons.

4.4. Data Management (GLP & USB Output)

The PH800 meter offers advanced data management capabilities.

  • Ibi ipamọ data: The meter can store up to 500 groups of measurement data, adhering to GLP (Good Laboratory Practice) standards.
  • USB Data Output: Connect the meter to a Windows-based computer via the USB cable to transfer stored data.
  • Sọfitiwia PC: Use the provided PC-Link software to view, analyze, and export data to spreadsheets for further analysis.
  • Auto-Timing Data Log: Utilize the auto-timing data log mode for professional measurements requiring timed data collection.
Apera PH800 pH meter connected to a laptop for USB data communication

Nọmba 4.5: The PH800 meter connected to a laptop via USB, illustrating its GLP data management capabilities with auto/manual data logging and 500 sets of data storage.

5. Itọju

Proper maintenance ensures the longevity and accuracy of your PH800 pH meter and electrode.

  • Ninu Electrode: Regularly clean the pH electrode with distilled water. For stubborn residues, use a mild cleaning solution recommended for pH electrodes.
  • Itọju itanna: When not in use, store the pH electrode in its protective cap filled with a suitable electrode storage solution (e.g., 3M KCl solution). Never store the electrode dry or in distilled water.
  • Ìmọ́tótó Mita: Wipe the meter's surface with a soft, damp cloth. Avoid using abrasive cleaners or solvents. The meter is IP54 splash-proof, but avoid direct water exposure.
  • Calibration Solutions: Keep calibration solutions sealed when not in use and replace them regularly to ensure accuracy.

6. Laasigbotitusita

This section addresses common issues you might encounter with your PH800 pH meter.

  • Awọn kika ti ko pe: Ensure the electrode is properly calibrated. Check the electrode's slope data in the self-diagnosis function; a low slope indicates an aging or faulty electrode. Clean the electrode thoroughly.
  • Slow Response: This can be due to a dry or contaminated electrode. Rehydrate the electrode in storage solution or clean it.
  • Ko si Ifihan/Agbara: Check the power adapter connection and ensure the outlet is functional.
  • Calibration Errors: Ensure you are using fresh, correct buffer solutions. Follow the calibration steps precisely. The self-diagnosis function can help identify specific calibration issues.
  • Awọn ọran Gbigbe Data: Verify the USB cable connection and ensure the PC-Link software is correctly installed on a compatible Windows system.

For persistent issues, refer to the detailed troubleshooting guide in the full user manual or contact Apera Instruments customer support.

7. Imọ ni pato

SipesifikesonuIye
Nọmba awoṣeAI521
pH Yiye0.01 pH ± 1 digit
pH Ibiti-2.00 to 19.99 pH
Ipinnu pH0.1 / 0.01 pH
Biinu iwọn otutu0 - 100°C Automatic
Ibi ipamọ data500 groups (GLP compliant)
AbajadeUSB
Asopọmọra IruOṣuwọn BNC
Idaabobo IngressIP54 Asesejade-ẹri
Ọja Mefa9.5 x 8 x 4 inches
Iwọn Ọja5.5 iwon
Awọn iwe-ẹriCE, RoHS, ISO 9001:2015

8. Atilẹyin ọja ati Support

The Apera Instruments PH800 Benchtop pH Meter is manufactured under an ISO 9001:2015 certified quality system and is CE and RoHS certified, ensuring high standards of quality and safety.

For specific warranty information, technical assistance, or service inquiries, please contact Apera Instruments directly through their official website or authorized distributors. Please have your model number (AI521) and purchase date available when contacting support.

Awọn iwe aṣẹ ti o jọmọ - AI521

Ṣaajuview APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter Instruction Manual
Comprehensive instruction manual for the APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter, covering specifications, operation, calibration, maintenance, and troubleshooting for laboratory use.
Ṣaajuview Apera TN500 Portable Turbidity Meter: Instruction Manual and Specifications
This document provides comprehensive instructions and technical specifications for the Apera TN500 Portable Turbidity Meter. Learn about its features, calibration, measurement procedures, data management, and maintenance for accurate water quality analysis.
Ṣaajuview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instruction manual for the Apera PH700 Benchtop pH Meter, covering features, specifications, operation, calibration, maintenance, and troubleshooting.
Ṣaajuview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Ṣaajuview LabSen 751 pH Electrode olumulo Afowoyi - Apera Instruments
Itọsọna olumulo fun Apera Instruments LabSen 751 Irin Alagbara Irin Sheath Spear pH Electrode, awọn ẹya alaye, awọn alaye imọ-ẹrọ, lilo, itọju, ati atilẹyin ọja fun idanwo pH ounje.
Ṣaajuview Apera Instruments PC60 Premium 5-in-1 Tester User Manual
Comprehensive user manual for the Apera Instruments PC60 Premium 5-in-1 Tester, covering pH, Conductivity, TDS, Salinity, and Temperature measurements. Includes setup, calibration, operation, maintenance, and troubleshooting.