Wilo Stratos PICO plus 25/1-3-130

Wilo Stratos PICO plus 25/1-6-130 High-Efficiency Heating Circulation Pump

Itọsọna olumulo

Model: Stratos PICO plus 25/1-3-130

1. Ifihan

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wilo Stratos PICO plus high-efficiency heating circulation pump. Please read these instructions carefully before installation and initial operation. Keep this manual for future reference.

The Wilo Stratos PICO plus is designed as a circulation pump for hot water heating systems and various climate control applications. It features advanced technology for energy efficiency and ease of use.

2. Alaye Aabo

Always observe the following safety instructions to prevent personal injury and damage to the equipment:

  • Installation and maintenance must only be carried out by qualified personnel in accordance with local regulations and standards.
  • Rí i dájú pé a ti ge ina agbara kuro ṣaaju fifi sori ẹrọ tabi iṣẹ itọju eyikeyi.
  • The pump operates with electrical voltage. Avoid contact with live parts.
  • Do not operate the pump if it is damaged or if the electrical cable is faulty.
  • Dabobo fifa soke lati Frost.
  • Wọ ohun elo aabo ti ara ẹni ti o yẹ (PPE) lakoko fifi sori ẹrọ ati itọju.

3. Eto ati fifi sori

The Wilo Stratos PICO plus pump is designed for comfortable replacement and compact installation. It features a Wilo Connector for quick and tool-free electrical wiring.

3.1 Iṣagbesori fifa soke

Mount the pump in the heating system piping. Ensure the flow direction arrow on the pump housing matches the system's flow direction. The pump can be installed horizontally or vertically, but the motor shaft must always be horizontal.

Wilo Stratos PICO plus pump installed in a heating system

Figure 1: Wilo Stratos PICO plus pump installed in a typical heating system setup, showing its compact integration with existing pipes and gauges.

Two Wilo Stratos PICO plus pumps installed in a heating system

Figure 2: Two Wilo Stratos PICO plus pumps integrated into a larger heating system, demonstrating their versatility and ease of installation in various configurations.

3.2 Itanna Asopọ

The Wilo Connector simplifies electrical wiring. Ensure the power supply matches the pump's specifications (230 Volts). Connect the pump to a properly grounded electrical circuit.

Wilo Stratos PICO plus pump with Wilo Connector

olusin 3: Isunmọ view of the Wilo Stratos PICO plus pump, highlighting the Wilo Connector for electrical wiring and the insulation shell.

The pump comes with an insulation shell (Dämmschale) included in the scope of delivery to minimize heat loss.

4. Awọn ilana Iṣiṣẹ

The Wilo Stratos PICO plus features an intuitive LC display and precise setting options for optimal performance.

4.1 LC Display and Controls

The large LC display shows current power consumption, cumulative kWh, and volume flow. Functions and modes are displayed on the LC display and activated directly via the green button technology.

Wilo Stratos PICO plus LC display

Nọmba 4: Alaye view of the Wilo Stratos PICO plus LC display, showing various operational parameters and settings, including power consumption and volume flow.

Wilo Stratos PICO plus LC display close-up

Figure 5: Close-up of the Wilo Stratos PICO plus LC display, providing a clear view of the digital readouts for power (W), volume flow (m³/h), and cumulative energy consumption (kWh).

4.2 Operating Modes and Functions

  • Optimized Dynamic Adapt Function: Automatically adjusts pump performance to the system's requirements, ensuring energy efficiency.
  • Manual De-aeration Routine: Helps to remove air from the pump and system, preventing noise and ensuring proper operation.
  • Automatic Deblocking Function: Prevents the pump from seizing up after long periods of inactivity.

Refer to the on-screen menu for detailed navigation and setting adjustments using the green control button.

5. Itọju

The Wilo Stratos PICO plus is designed for low maintenance. Regular checks can help ensure its longevity and efficient operation.

  • Ayewo wiwo: Periodically check the pump for any signs of leaks, corrosion, or damage.
  • Titẹ Eto: Ensure the heating system pressure is within the recommended range.
  • Yiyọ afẹfẹ kuro: Utilize the manual de-aeration routine if you notice gurgling noises or reduced heating performance.
  • Ninu: Keep the exterior of the pump clean and free from dust and debris.

For any complex maintenance or repairs, contact a qualified service technician.

6. Laasigbotitusita

If you encounter issues with your Wilo Stratos PICO plus pump, refer to the following common troubleshooting steps:

  • Pump Not Running:
    • Ṣayẹwo awọn ipese agbara ati Circuit fifọ.
    • Ensure the electrical connection is secure.
    • Verify the pump is not in a standby or off mode on the display.
  • Noisy Operation / Gurgling:
    • Perform the manual de-aeration routine to remove trapped air.
    • Check system pressure.
  • Dinku Išẹ Alapapo:
    • Check pump settings on the LC display.
    • Ensure there is no air in the system.
    • Verify system pressure and flow.
  • Pump Seized:
    • The automatic deblocking function should prevent this. If it occurs, contact a qualified technician.

If the problem persists after attempting these steps, contact Wilo customer support or a certified service professional.

7. Awọn pato

Below are the technical specifications for the Wilo Stratos PICO plus 25/1-3-130 pump:

Ẹya ara ẹrọIye
OlupeseWILO SE
Awọn iwọn Ọja (L x W x H)15.6 x 18.6 x 11.6 cm
Iwọn2.04 kilo
Nọmba Awoṣe NkanStratos PICO plus 25/1-3-130
Àwọ̀Alawọ ewe
AraIgbalode
Ohun eloMetal, Carbon Steel
Orisun agbaraCable ina
Voltage230 Volts
Opoiye Awọn nkan1
Awọn batiri To waRara
Awọn batiri ti a beereRara
Apoju Awọn ẹya ara wiwaAlaye ko si
International Ìwé Code04048482754451
Wilo Stratos PICO plus performance curve

Figure 6: Performance curve for Wilo Stratos PICO plus pumps, illustrating head (H/m) versus flow rate (Q/m³/h) for different models (15, 25, 30/1-6 and 15, 25, 30/1-4).

8. Atilẹyin ọja ati Support

For warranty information, please refer to the documentation provided with your purchase or contact your local Wilo representative. For technical support, spare parts, or service, please visit the official Wilo webojula tabi kan si wọn onibara iṣẹ Eka.

Awọn iwe aṣẹ ti o jọmọ - Stratos PICO plus 25/1-3-130

Ṣaajuview Wilo-Stratos PICO Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the Wilo-Stratos PICO high-efficiency circulation pump for heating systems. Includes safety, technical data, and operational procedures.
Ṣaajuview Wilo-Stratos PICO Circulator fifa: Awọn ọna fifi sori Itọsọna
Iwe yii n pese itọnisọna ni kiakia fun Wilo-Stratos PICO circulator pump, ti a ṣe apẹrẹ fun awọn ọna ẹrọ alapapo omi gbona. O pẹlu fifi sori ẹrọ pataki ati alaye iṣiṣẹ, pẹlu itọka si ilana itọnisọna pipe.
Ṣaajuview Wilo-Stratos PICO-Z High-Efficiency Circulator Pump: Installation and Operating Instructions
Detailed installation and operating manual for the Wilo-Stratos PICO-Z high-efficiency circulator pump (Article No. 4258257). This guide covers safety, technical specifications, installation, operation, commissioning, maintenance, and troubleshooting for drinking water recirculation systems in industrial and building services applications.
Ṣaajuview Àwọn Ìlànà Fífi Sílẹ̀ àti Ìṣiṣẹ́ Wilo-Stratos PARA-C/-CZ
Àwọn ìlànà ìfisí àti ìṣiṣẹ́ tó péye fún ẹ̀rọ Wilo-Stratos PARA-C/-CZ tó ń ṣiṣẹ́ dáadáa. Ó ní ààbò, ìrìnnà, lílò, dátà ọjà, àpèjúwe, fífi sori ẹrọ, ṣíṣe iṣẹ́, ìtọ́jú, àti ṣíṣe àtúnṣe.
Ṣaajuview Каталог насосов Wilo для бытового применения: отопление, водоснабжение, водоотведение
Обзор высокоэффективных циркуляционныh насосов Wilo для систем отопления, водоснабжения и водоотвени. Информация для продавцов и монтажников.
Ṣaajuview Wilo-Stratos PARA-C/-CZ High-Efficiency Circulation Pump Installation and Operating Manual
Comprehensive installation, operation, and maintenance guide for the Wilo-Stratos PARA-C/-CZ high-efficiency circulation pump, covering safety, technical data, installation, and troubleshooting.