Apera Instruments AI223

Apera Instruments SX620 pH Pen Tester Kit

Awoṣe: AI223

Brand: Apera Instruments

Ọja Pariview

The Apera Instruments SX620 pH Pen Tester is engineered for precise and reliable pH measurements in a compact, user-friendly design. It is an economical solution for a wide range of liquid testing applications, including hydroponics, aquaculture, water treatment, and beverage production. Its slim 8mm probe is replaceable and ideal for use with test tubes.

Key Awọn ẹya ara ẹrọ

  • 0.01 pH accuracy for precise readings.
  • Automatic 3-point calibration for enhanced accuracy.
  • Automatic Temperature Compensation (ATC) from 0-60°C.
  • Slim, replaceable probe suitable for test tubes.
  • Intelligent functions: switchable temperature units (°F/°C), automatic power-off, low battery alarm, and pH probe invalidation reminder.
  • IP57 waterproof and dustproof rating, allowing it to float if dropped in water.

Package Awọn akoonu

  • 1 x Apera Instruments SX620 pH Pen Tester
  • 1 x SX620 pH Pen Kit (includes tester)
  • 3 x Premixed Calibration Solutions (pH 4.00, pH 7.00, pH 10.01)
  • 1 x 3M KCL Storage Solution
  • 2 x CR2032 Lithium Batteries (pre-installed or included)
  • 1 x Ọran Gbigbe To ṣee gbe
  • 1 x Lanyard
Apera Instruments SX620 pH Pen Tester Kit contents in blue carrying case

The complete kit, including the SX620 pH pen tester, calibration solutions, storage solution, and a carrying case.

Ṣeto

Fifi sori batiri

The SX620 pH Pen Tester uses two CR2032 lithium batteries. These are typically pre-installed or included in the kit. To install or replace batteries, locate the battery compartment, usually at the top of the meter, and follow the markings for correct polarity.

Initial Probe Preparation

Before first use, or after prolonged storage, remove the protective cap from the probe. Rinse the probe with distilled water. If the probe has dried out, soak it in 3M KCL storage solution for at least 30 minutes to rehydrate the electrode. Ensure the probe is fully immersed in the storage solution.

Apera Instruments SX620 pH Pen Tester

The Apera Instruments SX620 pH Pen Tester, showing its digital display and probe.

Isẹ

Titan / Pipa agbara

Press the power button (usually marked with a power symbol) to turn the meter on. Press and hold the power button for a few seconds to turn it off.

Isọdiwọn

For accurate readings, regular calibration is essential. The SX620 features 3-point automatic calibration.

  1. Prepare the calibration solutions (pH 7.00, pH 4.00, pH 10.01).
  2. Fi omi tí a ti yọ omi kúrò fọ̀ omi náà kí o sì fi omi kùn ún.
  3. Immerse the probe in the pH 7.00 buffer solution. Press the CAL button. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize and indicate completion.
  4. Rinse the probe again.
  5. Immerse the probe in the pH 4.00 buffer solution. Press CAL. Wait for stabilization.
  6. Rinse the probe again.
  7. Immerse the probe in the pH 10.01 buffer solution. Press CAL. Wait for stabilization.
  8. After successful 3-point calibration, the meter is ready for use.

Iwọn pH

Lati ṣe iwọn:

  1. Rii daju pe mita naa ti ni iwọntunwọnsi.
  2. Fi omi tí a ti yọ omi kúrò fọ̀ omi náà kí o sì fi omi kùn ún.
  3. Fi iwadi naa bọ inu sample solution. Ensure the probe tip is fully submerged.
  4. Gently stir the solution to ensure homogeneity.
  5. Wait for the reading on the display to stabilize. The meter will automatically compensate for temperature (ATC).
  6. Record the pH and temperature readings.
  7. Lẹ́yìn ìwọ̀n, fi omi tí a ti fọ̀ ọ́ mọ́lẹ̀ dáadáa.
Hand holding Apera Instruments SX620 pH Pen Tester in a test tube

The SX620 pH Pen Tester being used to measure pH in a slim test tube, demonstrating its compact design.

Iwọn otutu Unit Yipada

The meter can display temperature in Celsius (°C) or Fahrenheit (°F). Refer to the specific button or menu option in your manual for switching between these units. Typically, this involves a short press of a dedicated button or a combination of buttons.

Itoju

Ninu Iwadii

After each use, rinse the probe thoroughly with distilled water to remove any sample residue. Do not wipe the glass bulb, as this can cause static electricity and damage the sensitive membrane. If the probe becomes contaminated with oil or grease, clean it with a mild detergent solution, then rinse thoroughly with distilled water.

Ibi ipamọ Iwadi

Proper storage is crucial for probe longevity. Always store the probe in 3M KCL storage solution. Ensure the protective cap is filled with storage solution and securely placed over the probe tip. NEVER store the probe in distilled water or deionized water, as this will deplete the reference electrolyte and permanently damage the electrode.

Probe Invalidation Reminder

The meter features an intelligent function that reminds you when the pH probe may need replacement for optimal performance. Pay attention to this reminder and consider replacing the probe if readings become unstable or inaccurate despite proper calibration and cleaning.

Batiri Rirọpo

When the low battery alarm appears on the display, replace the CR2032 lithium batteries promptly to ensure continuous operation and accurate readings.

Laasigbotitusita

  • Inconsistent or Unstable Readings: This often indicates a dry or contaminated probe. Rehydrate the probe in 3M KCL storage solution for several hours or overnight. Clean the probe thoroughly. Ensure proper calibration.
  • Mita ko tan: Ṣàyẹ̀wò bí a ṣe ń fi bátìrì sí i kí o sì rí i dájú pé bátìrì náà kò ti tán. Rọpò bátìrì tí ó bá pọndandan.
  • Ikuna Iṣatunṣe: Ensure calibration solutions are fresh and not expired. Verify the probe is clean and properly hydrated. Repeat the calibration process carefully.
  • Itaniji Batiri Kekere: Replace the CR2032 lithium batteries immediately.
  • Probe Invalidation Reminder: This indicates the probe's lifespan is nearing its end. Consider replacing the probe for continued accurate performance.

Awọn pato

Nọmba awoṣeAI223
pH Ibiti0.00 - 14.00 pH
pH Yiye± 0.01 pH
Iwọn otutu0 - 60°C (32 - 140°F)
Yiye iwọn otutu±0.6°C
IsọdiwọnAutomatic 3-point (7.00, 4.00, 10.01)
Biinu Igba otutu Laifọwọyi (ATC)Bẹẹni
Orisun agbara2 x CR2032 Lithium Batteries
Mabomire RatingIP57
Ọja Mefa6 x 1 x 1 inches
Iwọn Nkan5 iwon
OlupeseApera Instruments
Ilu isenbaleChina

Atilẹyin ọja ati Support

Apera Instruments products are designed and manufactured to high quality standards. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Apera Instruments webojula.

For assistance, please contact Apera Instruments customer support directly.

Awọn iwe aṣẹ ti o jọmọ - AI223

Ṣaajuview Apera EC20 Apo Idanwo Conductivity: Ilana itọnisọna & Itọsọna
Iwe itọnisọna pipe fun Apera EC20 Oluṣeto Imudaniloju Apo. Kọ ẹkọ nipa iṣeto, isọdọtun, wiwọn adaṣe, awọn pato imọ-ẹrọ, ati alaye atilẹyin ọja.
Ṣaajuview Apera Instruments PH1 Iye pH Apo Olumulo Olumulo
Itọsọna olumulo fun Apera Instruments PH1 Apo Idanwo pH Iye. Pese awọn ilana alaye lori iṣeto, isọdiwọn, wiwọn, awọn eto paramita, awọn alaye imọ-ẹrọ, itọju iwadii, laasigbotitusita, rirọpo batiri, ati alaye atilẹyin ọja.
Ṣaajuview Apera GroStar GS2 Premium Soil pH Pen Tester User Manual | Accurate Soil Testing
Comprehensive user manual for the Apera GroStar GS2 Premium Soil pH Pen Tester. Learn about calibration, measurement, troubleshooting, and maintenance for accurate soil pH testing.
Ṣaajuview Apera Instruments PC60 Premium Multi-Parameter Tester Instruction Manual
Comprehensive instruction manual for the Apera Instruments PC60 Premium Multi-Parameter Tester, covering battery installation, keypad functions, preparation, pH and conductivity calibration and measurement, parameter settings, technical specifications, icons, probe replacement, and warranty information.
Ṣaajuview Apera Instruments PH20 Iye pH Apo Olumulo Olumulo
Iwe afọwọkọ olumulo pipe fun Apera Instruments PH20 Iye pH Test Kit, fifi sori ẹrọ batiri, awọn iṣẹ bọtini foonu, isọdiwọn, awọn eto paramita, laasigbotitusita, awọn alaye imọ-ẹrọ, ati alaye atilẹyin ọja.
Ṣaajuview Apera PH20 Value pH Tester Kit User Manual - Guide and Specifications
This user manual provides comprehensive instructions for the Apera PH20 Value pH Tester Kit, covering setup, calibration, measurement, maintenance, troubleshooting, and technical specifications. Learn how to use and care for your pH tester.