Jaycar MP3087

Powertech 0-32V DC Dual Output Laboratory Power Supply

Awoṣe: MP3087

Ọrọ Iṣaaju

The Powertech MP3087 is a versatile 0-32V DC Dual Output Laboratory Power Supply designed for precision applications. It features automatic constant voltage (CV) or constant current (CC) transfer, ensuring stable power delivery. Its dual outputs can operate independently, or be configured in parallel or series to achieve various voltage and current combinations. Each output is equipped with independent digital voltage and current meters, providing clear, backlit readings for accurate monitoring. Coarse and fine controls allow for precise adjustment of voltage ati lọwọlọwọ ifilelẹ.

Awọn Itọsọna Aabo

Please read and understand all safety instructions before operating the power supply. Failure to do so may result in injury or damage to the equipment.

Ọja Pariview

Awọn iṣakoso nronu iwaju ati Awọn itọkasi

Iwaju view of the Powertech MP3087 Dual Output Laboratory Power Supply

olusin 1: Iwaju view of the Powertech MP3087 showing dual displays, control knobs, and output terminals.

The front panel of the MP3087 is intuitively designed for ease of use, featuring two identical sets of controls for each independent output, plus central controls for power and output configuration.

Ru Panel Awọn ẹya ara ẹrọ

Ẹyìn view of the Powertech MP3087 Dual Output Laboratory Power Supply

olusin 2: Ẹyìn view of the Powertech MP3087 showing the power input, fuse holder, and cooling fan.

The rear panel houses essential connections and cooling components.

Ṣeto

  1. Ṣii silẹ: Fi ìṣọ́ra yọ agbára iná mànàmáná kúrò nínú àpótí rẹ̀. Ṣàyẹ̀wò bóyá ó ti bàjẹ́ nígbà tí o bá ń rìnrìn àjò.
  2. Ibi: Place the unit on a stable, level surface with adequate ventilation space around it (at least 10 cm on all sides, especially the rear). Avoid placing it near heat sources or in direct sunlight.
  3. Asopọ agbara: Ensure the POWER switch on the front panel is in the OFF position. Connect the supplied AC power cord to the AC Power Input on the rear panel and then to a grounded wall outlet.
  4. Ṣayẹwo akọkọ: Turn the POWER switch ON. The digital displays should illuminate, showing default voltage ati awọn kika lọwọlọwọ.

Awọn ilana Iṣiṣẹ

The Powertech MP3087 offers flexible operation modes to suit various laboratory and testing requirements.

1. Independent Operation

In this mode, each output functions as a separate, isolated power supply.

  1. Ensure both PARALLEL and SERIES buttons are disengaged (not pressed in).
  2. Tan ipese agbara.
  3. For each output, adjust the VOL-ADJ (coarse and fine) knobs to set the desired output voltage.
  4. Adjust the CUR-ADJ (coarse and fine) knobs to set the desired current limit. It is recommended to set the current limit slightly above the expected operating current of your load to prevent unintended current limiting.
  5. Connect your load to the respective output terminals (Red for positive, Black for negative).
  6. Monitor the displays for actual voltage and current draw. The CC/CV indicator will show the operating mode.

2. Series Operation (Increased Voltage)

To combine the voltage of both outputs, use the series mode. The total output voltage will be the sum of the individual output voltages, while the current limit will be determined by the lower of the two set current limits.

  1. Ensure the power supply is OFF.
  2. Press the SERIES button on the front panel.
  3. Connect the positive (+) terminal of Output 1 to the negative (-) terminal of Output 2 using a short, heavy-gauge wire.
  4. The combined output will be available from the negative (-) terminal of Output 1 and the positive (+) terminal of Output 2.
  5. Tan ipese agbara.
  6. Adjust the VOL-ADJ and CUR-ADJ knobs for both outputs to achieve the desired total voltage and current limit. Note that the current limit will be the lowest setting of the two outputs.
  7. Connect your load to the combined output terminals.

3. Parallel Operation (Increased Current)

To combine the current capacity of both outputs, use the parallel mode. The total output current will be the sum of the individual output currents, while the voltage will be determined by the lower of the two set voltages.

  1. Ensure the power supply is OFF.
  2. Press the PARALLEL button on the front panel.
  3. Connect the positive (+) terminal of Output 1 to the positive (+) terminal of Output 2 using a short, heavy-gauge wire.
  4. Connect the negative (-) terminal of Output 1 to the negative (-) terminal of Output 2 using a short, heavy-gauge wire.
  5. The combined output will be available from either set of connected terminals.
  6. Tan ipese agbara.
  7. Adjust the VOL-ADJ and CUR-ADJ knobs for both outputs to achieve the desired total current and voltage. Note that the voltage will be the lowest setting of the two outputs.
  8. Connect your load to the combined output terminals.

Itoju

Proper maintenance ensures the longevity and reliable operation of your power supply.

Laasigbotitusita

IsoroOwun to le FaOjutu
Ẹka ko ni agbara lori.Kò sí agbára AC; fíúsì tí ó fẹ́; páìpù agbára.Check AC power cord connection and wall outlet. Check and replace fuse if necessary. Ensure power switch is ON.
Ko si voltage/lọwọlọwọ.Output terminals not connected; Current limit set too low; Overload protection activated.Ensure load is properly connected. Increase current limit. Reduce load or check for short circuit in load.
O wu voltage/current fluctuates.Unstable AC input; Loose connections; Faulty load.Check AC power source stability. Secure all connections. Test with a different load.
Unit overheats.Afẹ́fẹ́ dí; Ẹrù tó pọ̀ jù.Ensure ventilation openings are clear. Reduce load or operate within specified limits.

Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
AwoṣeMP3087
O wujade Voltage0-32V DC (per channel)
Ijade lọwọlọwọ0-3A (per channel)
Ojade IrisiDual, Independent, Series, Parallel
IfihanDigital Voltage and Current Meters (Backlit)
Awọn ọna ṣiṣeIbakan Voltage (CV), Constant Current (CC)
Iṣagbewọle Voltage220-240V AC, 50/60Hz (as per rear panel image)
Fiusi Rating1.5A (as per rear panel image)
Awọn iwọnApprox. 40 x 26 x 18.5 cm (from product title)
IwọnIsunmọ. 9.97 kg
Ohun eloPolycarbonate (PC)

Atilẹyin ọja ati Support

This Powertech product is covered by a standard manufacturer's warranty. For specific warranty terms, duration, and conditions, please refer to the documentation provided with your purchase or contact Jaycar customer support.

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact your retailer or the manufacturer's authorized service center. Keep your purchase receipt as proof of purchase for warranty claims.