Pedrollo JSWm/2CX

PEDROLLO JSWm/2CX Self-Priming Water Pump User Manual

Model: JSWm/2CX | Brand: Pedrollo

Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your PEDROLLO JSWm/2CX self-priming water pump. Please read these instructions carefully before installation or use and retain them for future reference.

PEDROLLO JSWm/2CX Self-Priming Water Pump

Nọmba 1: PEDROLLO JSWm/2CX Self-Priming Water Pump. This image shows the blue-colored pump unit with its motor housing and pump body, designed for efficient water transfer.

Alaye Aabo

Always observe the following safety precautions to prevent injury or damage to the pump:

  • Ensure the pump is installed by a qualified professional.
  • Ge asopọ agbara ṣaaju ṣiṣe eyikeyi itọju tabi iṣẹ.
  • Do not operate the pump with flammable or corrosive liquids.
  • Dáàbò bo fifa omi kuro ninu otutu otutu ti o tutu.
  • Ensure proper grounding of the electrical connection.

Ọja Pariview

The PEDROLLO JSWm/2CX is a self-priming centrifugal pump designed for reliable water transfer. It is suitable for pumping clean water and liquids that are not chemically aggressive to the pump's components. Its self-priming capability allows it to draw water even when air is present in the suction line, making it ideal for domestic water supply, small to medium autoclave tank systems, and garden irrigation.

Awọn ẹya pataki:

  • Self-priming design for efficient operation.
  • Suitable for clean water and non-aggressive liquids.
  • Robust construction with stainless steel components.
  • Designed for continuous duty in domestic and garden applications.

Eto ati fifi sori

Proper installation is crucial for the pump's performance and longevity. Consult a qualified technician for installation.

  1. Ibi: Install the pump in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure adequate space for maintenance.
  2. Iṣagbesori: Securely fasten the pump to a stable, level surface using appropriate bolts to minimize vibration.
  3. Pipin:
    • Use pipes of adequate diameter to minimize friction losses.
    • Ensure all connections are airtight, especially on the suction side, to prevent air ingress.
    • Install a foot valve with a strainer at the end of the suction pipe to prevent debris from entering the pump and to maintain prime.
    • Install a gate valve on both the suction and discharge sides for isolation during maintenance.
  4. Asopọmọra itanna:
    • Connect the pump to a suitable power supply (220-230V, 50Hz) as indicated on the motor's data plate.
    • Ensure the electrical circuit is protected by a residual current device (RCD) and an appropriately rated circuit breaker.
    • Verify proper grounding according to local electrical codes.
  5. Ipilẹṣẹ: Before initial startup, completely fill the pump casing and the suction line with clean water through the priming port. This is essential for self-priming pumps to initiate operation.

Awọn ilana Iṣiṣẹ

  1. Ibẹrẹ Ibẹrẹ: After installation and priming, open the discharge valve fully. Switch on the power supply. The pump should start and begin to draw water.
  2. Ise Tesiwaju: Monitor the pump for unusual noises or vibrations. Ensure the pump is not running dry, as this can cause severe damage.
  3. Paade: To stop the pump, switch off the power supply. If the pump is part of an automatic system (e.g., with a pressure switch), it will start and stop automatically based on demand.
  4. Awọn idiwọn iwọn otutu:
    • Liquid temperature: up to +40 °C.
    • Ambient temperature: -10 °C to +40 °C.

Itoju

Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect power before maintenance.

  • Awọn iṣayẹwo deede: Inspect the pump and piping for leaks, corrosion, or damage.
  • Isọmọ Strainer: Periodically clean the foot valve strainer to prevent blockages and maintain flow.
  • Igba otutu: In areas prone to freezing, drain the pump completely and store it in a warm, dry place, or insulate it adequately to prevent damage from ice expansion.
  • Ayẹwo mọto: Ensure the motor's cooling fins are free from dust and debris to prevent overheating.

Laasigbotitusita

IsoroOwun to le FaOjutu
Pump ko bẹrẹNo power supply; Motor overload; Seized impeller.Check power connection and circuit breaker; Reset thermal overload; Contact service technician.
Pump runs but no water is deliveredPump not primed; Air leak in suction line; Foot valve clogged; Suction lift too high.Re-prime the pump; Check all suction connections for leaks; Clean foot valve strainer; Reduce suction lift if possible.
Ìṣàn omi tàbí ìfúnpá tí ó dínkùPartial blockage in piping; Worn impeller; Air in system.Inspect and clear piping; Contact service technician for impeller replacement; Bleed air from system.
Ariwo pupọ tabi gbigbọnCavitation (air in water); Loose mounting; Bearing wear.Check for air leaks and ensure proper priming; Tighten mounting bolts; Contact service technician.

Awọn pato

ParamitaIye
AwoṣeJSWm/2CX
BrandPedrollo
Agbara (HP)1 HP
Voltage / Igbohunsafẹfẹ220-230V / 50Hz
Oṣuwọn Sisan ti o pọju70 liters fun iseju
Liquid otutu RangeUp to +40 °C
Ibaramu otutu Ibiti-10 °C si +40 °C
Ohun eloStainless Steel (pump body components)
ASINB07HMZ2DKQ
International Ìwé Code08052230012515

Note: The specification for "Power: 220 Watts" found in some product listings may refer to a specific component or a different metric. The pump's performance is rated at 1 HP.

Atilẹyin ọja ati Support

For warranty information, technical support, or spare parts, please contact your authorized Pedrollo dealer or visit the official Pedrollo webojula. Tọju iwe-ẹri rira rẹ bi ẹri rira.

Olupese: PEDROLLO

Awọn iwe aṣẹ ti o jọmọ - JSWm/2CX

Ṣaajuview Pedrollo EP Electronic Protection Device - User Manual & Datasheet
Comprehensive guide to the Pedrollo EP Electronic Protection Device, detailing its features, technical specifications, installation, and operation. Protects pumps from dry running, overcurrent, overvoltage, ati undervoltage. Suitable for domestic use.
Ṣaajuview Pedrollo E1-E2 Electronic Electrical Panels for Pumps
Comprehensive guide to Pedrollo E1 and E2 electronic control panels, designed for managing single or dual pump systems in residential, commercial, and industrial settings. Features include selectable operating modes, dry-running protection, and intuitive user interfaces for efficient pump operation.
Ṣaajuview Pedrollo STEADYPRES: Variatore Elettronico di Frequenza per Pompe
Manuale completo per il Pedrollo STEADYPRES, un inverter per il controllo di elettropompe. Offre istruzioni dettagliate su installazione, configurazione, funzionamento, gestione allarmi, risoluzione guasti e dati tecnici per ottimizzare la pressione e proteggere la pompa.
Ṣaajuview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.
Ṣaajuview JSW JET Self-Priming Pumps: Performance, Technical Data, and Materials
Detailed technical specifications, performance curves, dimensions, materials, and application data for JSW JET self-priming pumps by Pedrollo. Suitable for domestic, civil, and industrial use.
Ṣaajuview Pedrollo PLURIJET 80-100 & 80X-100X Ara-Priming Multi-Stage Awọn ifasoke Datasheet
Awọn alaye imọ-ẹrọ pipe, data iṣẹ ṣiṣe, itọnisọna fifi sori ẹrọ, ati awọn alaye ikole fun Pedrollo PLURIJET 80-100 ati PLURIJET 80X-100X jara ti ara-priming pupọ-stage bẹtiroli, o dara fun abele ati ilu awọn ohun elo.