DXQ FL-40GMB12V000001

DXQ FL-40 High Pressure Diaphragm Pump User Manual

Model: FL-40GMB12V000001 | Brand: DXQ

1. Ifihan

Thank you for choosing the DXQ FL-40 High Pressure Diaphragm Pump. This manual provides essential information for the proper installation, operation, and maintenance of your pump. Please read it thoroughly before use to ensure safe and efficient performance.

DXQ FL-40 High Pressure Diaphragm Pump with clear filter housing

Figure 1: DXQ FL-40 High Pressure Diaphragm Pump

Awọn ẹya pataki:

  • Ohun elo ti o tọ: Constructed from high-strength cast iron with powder coating, ensuring waterproof and rust-resistant properties for long-term use.
  • Powerful Automatic Pressure Pump: A fully automatic self-priming pump with a maximum flow rate of 17 L/min and an inlet PSI set to Max 40PSI (2.76Bar). Operates on 12V AC power.
  • Idaabobo Abo: Features built-in thermal protection and automatic pressure protection. Designed for long service life with quiet operation and no leakage.
  • Fifi sori ni kiakia: Compact size, lightweight design, and stable performance facilitate instant assembly.
  • Awọn ohun elo to pọ: Suitable for various uses including food and beverage filling, liquid transfer, clean machine requirements, road work, and cooling systems.
Collage of various applications for the pump including kitchen sink, water heater, soda dispenser, agricultural drone, pressure washing, and solar water heater

Figure 2: Wide range of applications for the FL-40 pump

2. Awọn ilana aabo

Always observe the following safety precautions to prevent injury or damage to the pump.

  • Rii daju pe ipese agbara ibaamu voltage ibeere (12V).
  • Do not operate the pump with damaged wiring or connections.
  • Yẹra fún lílo pọ́ọ̀ǹpù náà fún ìgbà pípẹ́, nítorí pé èyí lè fa ìbàjẹ́.
  • Rí i dájú pé afẹ́fẹ́ ń yọ́ ní àyíká pọ́ọ̀ǹpù náà nígbà tí a bá ń ṣiṣẹ́.
  • Do not use the pump for flammable liquids or in explosive atmospheres.
  • Pa ọwọ ati awọn aṣọ alaimuṣinṣin kuro lati awọn ẹya gbigbe.
  • Disconnect power before performing any maintenance or troubleshooting.
  • The pump features built-in thermal protection to prevent overheating. If the pump stops unexpectedly, allow it to cool down before restarting.
Diagram showing the internal motor of the pump with an arrow indicating thermal protection

Figure 3: Thermal Protection feature of the pump

3. Awọn irinše To wa

The DXQ FL-40 High Pressure Diaphragm Pump package typically includes the following components:

  • 1 x Diaphragm Water Pump
  • 1 x Ajọ
  • 3 x Fittings (various types for connection)
Sun mo tipetipe view of the included filter and various hose fittings

Figure 4: Included filter and fittings

Labeled diagram of the pump showing water outlet connector, stable bracket, pump wire, and water inlet connector

Figure 5: Key components and connections of the pump

4. Eto ati fifi sori

Follow these steps for quick and proper installation of your diaphragm pump:

  1. Iṣagbesori: Securely mount the pump in a dry, well-ventilated area using the stable bracket. Ensure it is on a flat, stable surface to minimize vibration.
  2. Asopọ ti nwọle: Connect the water inlet hose to the designated inlet port (often labeled 'Inlet' or indicated by an arrow pointing towards the pump). It is recommended to install the included filter on the inlet line to prevent debris from entering the pump.
  3. Asopọmọra iṣan: Connect the water outlet hose to the designated outlet port (often labeled 'Outlet' or indicated by an arrow pointing away from the pump).
  4. Asopọmọra itanna: Connect the pump's power wires to a 12V DC power source. Ensure correct polarity (red wire to positive, black wire to negative). It is advisable to install an inline fuse for protection.
  5. Fi Pump naa pamọ (ti o ba jẹ dandan): While this is a self-priming pump, ensuring the inlet line is filled with water before the first use can aid in faster priming.
  6. Ṣayẹwo fun Leaks: After all connections are made, slowly introduce water into the system and check for any leaks at the fittings. Tighten connections as needed.
Diagram showing the pump connected to inlet and outlet hoses with a filter on the inlet, and an arrow indicating water flow direction

Figure 6: Fast assembly and water flow direction

5. Isẹ

Once installed, operating the DXQ FL-40 pump is straightforward:

  • Bibẹrẹ fifa soke: Ensure all connections are secure and the power source is ready. Apply 12V DC power to the pump. The pump will begin to operate and self-prime.
  • Isẹ aladaaṣe: The pump is designed to automatically turn on when water is demanded (e.g., a faucet is opened) and turn off when the demand stops and pressure builds up in the system.
  • Flow and Pressure: The pump delivers a maximum flow of 17 L/min and maintains pressure up to 40 PSI.
  • Abojuto: Periodically check the pump for unusual noises, vibrations, or leaks during operation.

6. Itọju

Regular maintenance ensures the longevity and optimal performance of your pump:

  • Fifọ́ àlẹ̀: Regularly inspect and clean the inlet filter to prevent clogging and maintain optimal flow. Disconnect power, remove the filter housing, clean the mesh screen, and reassemble.
Comparison image showing the included metal filter on the left and a different type of filter on the right

Figure 7: The included metal filter for debris prevention

  • Ṣayẹwo Asopọmọra: Periodically check all hose and electrical connections for tightness and signs of wear.
  • Igba otutu (ti o ba wulo): If the pump is used in an environment where temperatures drop below freezing, ensure it is drained completely or protected with RV antifreeze to prevent damage from freezing water.
  • Isọsọ gbogboogbo: Jeki ita ti fifa soke mọ ki o si ni ominira lati idoti ati idoti.

7. Laasigbotitusita

Tọkasi tabili ni isalẹ fun awọn ọran ti o wọpọ ati awọn ojutu wọn:

IsoroOwun to le FaOjutu
Pump ko ṣiṣẹNo power; Loose wiring; Blown fuse; Motor faultCheck power supply; Secure connections; Replace fuse; Contact support
Ṣíṣàn omi kekere tabi titẹClogged inlet filter; Kinked or restricted hose; Air in system; Low voltageClean filter; Straighten hose; Bleed air from system; Check power supply
Fifa gbalaye continuouslyLeak in system; Pressure switch malfunction; Open faucetCheck for leaks and repair; Contact support for pressure switch; Close all faucets
Pump jẹ alariwoAir in system; Loose mounting; Debris in pumpBleed air; Secure mounting; Disconnect power and inspect pump (if safe)
Omi n jo lati fifa sokeLoose fittings; Damaged seals/diaphragmTighten fittings; Contact support for seal replacement

8. Imọ ni pato

Detailed specifications for the DXQ FL-40 Diaphragm Pump:

SipesifikesonuIye
OlupeseBananaB (DXQ)
Nọmba awoṣeFL-40GMB12V000001
Ọja Mefa36 x 12 x 10 cm (isunmọ. 14.2 x 4.7 x 3.9 inches)
IwọnKg 2.4 (isunmọ 5.3 lbs)
Àwọ̀Dudu
AraDiaphragm
Ohun eloSimẹnti Irin
Orisun agbara12V DC
Voltage12 Volts
Oṣuwọn Sisan ti o pọju17 liters fun iseju
Iwọn titẹ to pọju40 PSI (Ipa 2.76)
Max gbe Iga2 Mita
Awọn batiri To wa?Rara
Ti beere awọn batiri?Rara
Image showing the dimensions of the pump: 10 inches long, 4.3 inches wide, and 4.3 inches high

Figure 8: Pump dimensions

Close-up of the pump highlighting its cast iron material construction

Figure 9: Durable Cast Iron Material

9. atilẹyin ọja Information

For specific warranty terms and conditions, please refer to the product packaging or contact the seller/manufacturer directly. Keep your proof of purchase for any warranty claims.

10. Onibara Support

If you encounter any issues not covered in this manual or require further assistance, please contact the seller or manufacturer through the platform where you purchased the product. Provide your model number and a detailed description of the issue for faster service.

Awọn iwe aṣẹ ti o jọmọ - FL-40GMB12V000001

Ṣaajuview OMEGA FL-800 Series Flowmeter Installation and Operation Manual
Comprehensive guide for the OMEGA FL-800 Series Flowmeter, covering installation, operation, maintenance, accuracy tips, specifications, safety warnings, warranty, and contact information.
Ṣaajuview 2007 Nissan Furontia idana System Service Afowoyi
Itọsọna iṣẹ okeerẹ fun 2007 Nissan Frontier, awọn ilana alaye fun eto idana, pẹlu awọn iṣọra, igbaradi, ojò epo, fifa epo, àlẹmọ epo, ati ẹyọ sensọ. Ni wiwa yiyọ kuro, fifi sori ẹrọ, itusilẹ, apejọ, ati awọn pato.
Ṣaajuview Fujinon Lens Mount Yiyi Itọsọna Atunṣe ati Awọn pato
Itọsọna alaye lori bi o ṣe le ṣatunṣe iyipo ti awọn fifin lẹnsi kamẹra Fujinon, pẹlu awọn ilana igbesẹ-nipasẹ-igbesẹ ati atokọ okeerẹ ti awọn awoṣe lẹnsi pẹlu awọn iwọn sensọ wọn ati awọn alaye iyipo.
Ṣaajuview Phoenix Olubasọrọ FL Yipada 1000 Series User Afowoyi
Yi olumulo Afowoyi pese okeerẹ itoni fun Phoenix Olubasọrọ FL SWITCH 1000 jara unmanaged dín àjọlò yipada. O ni wiwa alaye pataki lori ailewu, fifi sori ẹrọ, iṣẹ ṣiṣe, data imọ-ẹrọ, ati aṣẹ fun ọpọlọpọ awọn awoṣe, ni idaniloju imuṣiṣẹ to dara ati lilo ninu awọn ohun elo Nẹtiwọọki ile-iṣẹ.
Ṣaajuview GLEDOPTO RGB+CCT Smart Lighting User Manual & Specifications
Comprehensive user instructions and technical specifications for GLEDOPTO RGB+CCT smart lighting products, including remote controls, flood lights, and garden lamps. Learn about features, compatibility, installation, and operation.
Ṣaajuview Ìwé Ìfilọ́lẹ̀ àti Ìṣiṣẹ́ Titus FlowBar Architectural Linear Diffuser
Ìwé ìtọ́sọ́nà tó péye fún àwọn ẹ̀rọ ìfọ́mọ́ra tí wọ́n ń pè ní Titus FlowBar architecture diffusers, àwọn àwòṣe FL-10, FL-15, FL-20, FL-25, àti FL-30. Ó bo àjà líle, àjà acoustic, àti àwọn ìlànà gígé pápá.