Ọrọ Iṣaaju
The Tekmar 150 One Stage Setpoint Control is designed to precisely manage a single component within a heating or cooling system to maintain a specific temperature. This control is versatile, suitable for applications ranging from heating swimming pools to maintaining consistent slab temperatures in commercial car wash bays. It regulates a constant water temperature setpoint for either heating or cooling operations.
Ọja Pariview
The Tekmar 150 operates a single relay to control a device such as a boiler, pump, or valve. It features a digital display for easy monitoring and adjustment. The control is equipped with microprocessor technology for reliable performance.

Aworan 1: Iwaju view of the Tekmar 150 One Stage Setpoint Control. It is a white rectangular unit with a gray faceplate featuring a digital display at the top and three control buttons below it. The Tekmar logo and model number are visible on the lower left of the faceplate.
Key Awọn ẹya ara ẹrọ
- Designed to operate a single component of a heating or cooling system.
- Maintains a precise set temperature.
- Ifihan oni-nọmba fun awọn kika kika ti o han gbangba.
- Heat or cool setpoint control functionality.
- Normally open and normally closed relay options.
- Pulse width modulation control.
- Microprocessor control for enhanced accuracy.
- Includes Universal Sensor 071.
Awọn Itọsọna fifi sori ẹrọ
The Tekmar 150 control is intended for indoor use only. Proper installation is crucial for optimal performance and safety. It is recommended that installation be performed by a qualified technician.
Awọn ipo Ayika:
- Iwọn otutu ibaramu: -20 si 120°F (-30 si 50°C).
- Ọriniinitutu ibatan: ≤90% Non-condensing.
Awọn Isopọ Itanna:
Ensure all electrical connections comply with local codes and regulations. The control requires a specific power supply and relay rating:
- Ibi ti ina elekitiriki ti nwa: 24 V (ac) ±10%, 50/60 Hz, 1.3 VA, or 24 V (dc) ±10%, 0.02 A.
- Yii: 240 V (ac) 8 A maximum, 1/4 hp.
Connect the Universal Sensor 071 as per the wiring diagram provided with the product packaging (not included in this manual).
Awọn ilana Iṣiṣẹ
The Tekmar 150 control features a user-friendly interface for setting and monitoring temperatures.
Ifihan Digital:
The digital display shows the current temperature and allows for viewing and adjusting setpoints, differentials, and delay cycles.
Setting the Setpoint:
- Press the button labeled "Setpoint" (refer to Image 1 for button location).
- Use the Up (▲) and Down (▼) arrow buttons to adjust the desired temperature setpoint.
- The control will automatically save the new setpoint after a few seconds of inactivity or by pressing the Setpoint button again.
Adjusting Differential and Delay Cycle:
Similar to setting the setpoint, dedicated buttons (or a sequence of button presses, depending on the model's exact interface) are used to access and modify the differential and delay cycle settings. Consult the detailed wiring and operation guide included with your product for specific instructions on these advanced settings.
Heating or Cooling Mode:
The control can be configured for either heating or cooling applications. This setting is typically configured during initial setup and determines whether the relay activates when the temperature falls below (heating) or rises above (cooling) the setpoint.
Itoju
The Tekmar 150 One Stage Setpoint Control is designed for minimal maintenance. Periodically inspect the unit for any visible damage or loose connections. Ensure the area around the control is clean and free from obstructions to allow for proper operation and temperature sensing. Do not attempt to open or repair the unit yourself; refer to qualified service personnel.
Laasigbotitusita
If the control is not functioning as expected, consider the following basic troubleshooting steps:
- Ko si Ifihan/Agbara: Check the power supply connections and ensure the correct voltage ti wa ni ipese si awọn kuro.
- Kika iwọn otutu ti ko tọ: Verify that the Universal Sensor 071 is properly connected and positioned correctly. Ensure it is not exposed to direct heat sources or drafts that could affect its accuracy.
- Device Not Activating: Check the setpoint and ensure it is appropriate for the desired heating or cooling action. Verify the relay connections and ensure the controlled device (boiler, pump, valve) is receiving power and functioning correctly.
- Control Not Responding: If the buttons are unresponsive, try cycling the power to the unit (turn off, wait 30 seconds, then turn on).
For persistent issues, contact Tekmar customer support or a qualified HVAC technician.
Imọ ni pato
| Paramita | Iye |
|---|---|
| Awoṣe | 150 |
| Iṣakoso Iru | Microprocessor Iṣakoso |
| Awọn iwọn (H x W x D) | 4-3/4" H x 2-7/8" W x 7/8" D (120 x 74 x 22 mm) |
| Ambient Conditions (Temperature) | -20 si 120°F (-30 si 50°C) |
| Ambient Conditions (Humidity) | RH ≤90% Non-condensing |
| Ipese Agbara (AC) | 24 V (ac) ±10%, 50/60 Hz, 1.3 VA |
| Ipese Agbara (DC) | 24 V (dc) ±10%, 0.02 A |
| Yii Rating | 240 V (ac) 8 A max, 1/4 hp |
| To wa Awọn ẹya ẹrọ | Sensọ gbogbo agbaye 071 |
| Iwọn Nkan | 12.5 iwon |
Package Awọn akoonu
- Tekmar 150 Ọkan Stage Setpoint Control
- Sensọ gbogbo agbaye 071
Alaye Aabo pataki
Ikilọ: The Tekmar 150 is a control device and is kii ṣe designed to be a safety (limit) control. Always ensure that appropriate safety devices and limit controls are installed and functioning correctly in your heating or cooling system to prevent hazardous conditions. Failure to do so may result in property damage, injury, or death.
Always disconnect power before servicing the unit or making any electrical connections. Installation and servicing should only be performed by qualified personnel.
Atilẹyin ọja ati Support
For warranty information and technical support, please refer to the documentation provided with your product or visit the official Tekmar webojula. O tun le ṣàbẹwò awọn Tekmar Store on Amazon fun afikun ọja alaye.