Emerson 1E78-140

Ìwé Ìtọ́sọ́nà Olùlò Thermostat Heat Nikan ti Emerson 1E78-140

Àwòṣe: 1E78-140

Ọrọ Iṣaaju

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Emerson 1E78-140 Non-Programmable Heat Only Thermostat. Please read this manual thoroughly before installation and use to ensure proper function and safety.

The Emerson 1E78-140 is designed for use with most single-stage heat-only systems, including 24-volt and millivolt systems. It is not compatible with electric baseboard heat or certain other systems.

Eto ati fifi sori

Awọn irinṣẹ ti a beere

  • Screwdriver
  • Lilu (ti o ba nilo awọn ihò iṣagbesori titun)
  • Awọn yiyọ okun waya (ti o ba nilo)

Yọ kuro Thermostat Atijọ rẹ

  1. Turn off power to your heating system at the main fuse or circuit breaker panel.
  2. Yọ ideri ti thermostat atijọ rẹ kuro.
  3. Take a photo of the existing wiring connections for reference.
  4. Disconnect the wires from the old thermostat terminals, noting which wire was connected to each terminal.
  5. Remove the old thermostat base from the wall.

Iṣagbesori New Thermostat

  1. Ya ideri iwaju kuro ninu ipilẹ thermostat naa.
  2. Position the new thermostat base on the wall. Use the provided screws and anchors to secure it.

Asopọmọra

Pataki: Ensure power is off before wiring. This thermostat is for 2-wire heat-only systems. Connect wires only to R and W terminals.

Refer to the wiring diagram below. Identify each wire attached to the old thermostat by taking a photo of old wiring.

Wiring diagram for Emerson 1E78-140 thermostat showing connections for R and W terminals, along with included batteries and mounting screws.

Image: Wiring diagram for the Emerson 1E78-140 thermostat. It illustrates connections for 2-wire heat-only systems to R and W terminals. The image also shows two AAA Energizer batteries and various mounting screws and anchors included with the thermostat. A caution notice regarding battery life and freeze hazard is visible.

  • Connect the wire from your heating system's R terminal to the R terminal on the thermostat.
  • Connect the wire from your heating system's W terminal to the W terminal on the thermostat.

Fifi sori batiri

The thermostat requires two AAA batteries for operation. Install the batteries into the compartment located on the back of the thermostat, observing the correct polarity (+/-).

Iwaju view of the Emerson 1E78-140 Non-Programmable Heat Only Thermostat, displaying '70' on the digital screen and up/down temperature adjustment buttons.

Aworan: Iwaju view of the Emerson 1E78-140 thermostat. The digital display shows "70" as the current temperature. To the right of the display are two gray buttons for adjusting the temperature up and down. Below the Emerson logo, a system switch is visible, set to "OFF HEAT".

After wiring and battery installation, attach the thermostat front cover to the base.

Turn on power to your heating system at the main fuse or circuit breaker panel.

Awọn ilana Iṣiṣẹ

System Yipada

The system switch is located on the front of the thermostat. It has two positions:

  • PA: Turns the heating system off.
  • gbigbona: Activates the heating system to maintain the set temperature.

Ṣiṣeto iwọn otutu

Use the Up (▲) and Down (▼) buttons located next to the digital display to adjust your desired temperature setting. The thermostat will maintain this temperature with a precision of plus/minus 1 degree Fahrenheit.

Imọlẹ ẹhin

The digital display features a backlight for improved visibility, especially in low-light conditions. The backlight activates when buttons are pressed.

Itoju

Batiri Rirọpo

When the "Change Battery" indicator (a battery icon) is displayed on the screen, the batteries have limited remaining life and should be replaced soon. The system will not operate with dead batteries.

  1. Yọ ideri thermostat kuro.
  2. Yọ awọn batiri AAA atijọ kuro.
  3. Fi awọn batiri ipilẹ AAA tuntun meji sii, ni idaniloju polarity ti o pe.
  4. Rọpo ideri thermostat.

Ninu

Nu thermostat pẹlu asọ, damp asọ. Ma ṣe lo abrasive ose tabi epo.

Laasigbotitusita

IsoroOwun to le FaOjutu
Ifihan ti ṣofo tabi baibai.Awọn batiri ti o ku tabi kekere.Rọpo awọn batiri AAA meji.
Alapapo eto ko ni tan.
  • System switch is in OFF position.
  • Awọn batiri ti ku.
  • Power to heating system is off.
  • Ti firanṣẹ ti ko tọ.
  • Ṣeto iyipada eto si HEAT.
  • Rọpo awọn batiri.
  • Check circuit breaker/fuse for heating system.
  • Verify wiring connections (R and W terminals).
"Change Battery" icon displayed.Agbara batiri kekere.Replace the two AAA batteries promptly.

Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
BrandEmerson
Nọmba awoṣe1E78-140
Adarí IruTitari Bọtini
Pataki ẸyaIfihan iwọn otutu
Iwọn Iṣakoso IruAfowoyi
Awọn irinše to waThermostat, Temperature Sensor
Orisun agbaraElectric (2 AAA batteries for display/control)
Voltage24 Volts (for system operation)
Ifihan IruLED
Ọna IṣakosoFọwọkan (awọn bọtini)
Iṣagbesori IruÒgiri Ògiri
AraOni-nọmba
Imọlẹ ẹhinBẹẹni
IbamuJulọ nikan-stage heat-only systems (24V and millivolt). Not compatible with electric baseboard heat.
Itọkasi+/- 1 degree F
Apa view of the Emerson 1E78-140 thermostat held in a hand, showing its dimensions as 5.5 inches (14 cm) in height.

Aworan: A ẹgbẹ view of the Emerson 1E78-140 thermostat, held in a hand for scale. The image indicates the thermostat's height is 5.5 inches (14 cm).

Alaye atilẹyin ọja

Specific warranty details for the Emerson 1E78-140 thermostat are typically provided with the product packaging or can be obtained directly from the manufacturer, Emerson. Please refer to the documentation included in your product box or visit the official Emerson webojula fun awọn julọ lọwọlọwọ atilẹyin ọja ofin ati ipo.

Onibara Support

For technical assistance, troubleshooting beyond this manual, or inquiries regarding your Emerson 1E78-140 thermostat, please contact Emerson customer support. Contact information can usually be found on the product packaging or on the official Emerson webojula.

Awọn iwe aṣẹ ti o jọmọ - 1E78-140

Ṣaajuview Emerson 1F75C-11NP fifi sori ẹrọ igbona ti kii ṣe eto ati Awọn ilana iṣiṣẹ
Àwọn ìlànà ìfisí àti ìṣiṣẹ́ fún Emerson 1F75C-11NP Non-Programmable Single StagE Thermostat. Ó bo àwọn wáyà, ìṣètò, àtòjọ àwọn olùfisò, ìdánwò, àti ìṣòro.
Ṣaajuview Emerson 1F83C-11NP Thermostat fifi sori ẹrọ ati Itọsọna isẹ
Ìtọ́sọ́nà pípéye fún fífi sori ẹrọ àti lílo àwọn ẹ̀rọ Emerson 1F83C-11NPtagthermostat e. Ó bo àwọn wáyà, àwọn ohun èlò thermostat, àwọn àkójọ oúnjẹ olùfisẹ́ àti olùlò, ìṣòro, àti àwọn ìlànà pàtó.
Ṣaajuview Àwọn Ìlànà Fífi Thermostat Emerson 1E78-151 Sílẹ̀
Àwọn ìtọ́ni ìfisílé, àwọn àwòrán wáyà, àwọn ìlànà pàtó, àti ìtọ́sọ́nà ìṣòro fún thermostat Emerson 1E78-151 tí a kò lè ṣètò láti ọwọ́ White-Rodgers.
Ṣaajuview Emerson 1F83C-11NP fifi sori ẹrọ igbona ti kii ṣe eto ati Awọn ilana iṣiṣẹ
Ìtọ́sọ́nà ìfisílẹ̀ àti ìṣiṣẹ́ kíkún fún àwọn ọkọ̀ ayọ́kẹ́lẹ́ Emerson 1F83C-11NPtage thermostat ti kii-eto. Awọn wiwa wiwakọ, iṣeto ni, fifi sori ẹrọ ati awọn akojọ aṣayan olumulo, awọn pato, ati laasigbotitusita.
Ṣaajuview Emerson 1F83H-21PR Eto Ooru Pump Thermostat Fifi sori ẹrọ ati Itọsọna Iṣiṣẹ
Àwọn ìlànà ìfisí àti ìṣiṣẹ́ tó péye fún Emerson 1F83H-21PR 80 Series Programmable Heat Pump Thermostat. Kọ́ nípa wáyà, ìṣètò, àwọn àkójọ oúnjẹ olùlò, ìṣètò àkókò, àti ṣíṣe àtúnṣe ìṣòro.
Ṣaajuview Emerson 1F83C-11NP Thermostat: Fifi sori ẹrọ ati awọn ilana iṣiṣẹ
Ìtọ́sọ́nà pípéye fún ọkọ̀ ayọ́kẹ́lẹ́ Emerson 1F83C-11NPtagthermostat e, bo fifi sori ẹrọ, wayoyi, iṣẹ, fifi sori ẹrọ ati awọn akojọ aṣayan olumulo, awọn alaye pato, ati laasigbotitusita. Kọ ẹkọ bi o ṣe le ṣeto ati lo thermostat rẹ fun igbona ati itutu to dara julọ.