Apera Instruments AI1107

Apera Instruments 3M KCL Storage Soaking Solution

Awoṣe: AI1107

Brand: Apera Instruments

Ọja Pariview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Awọn ẹya pataki pẹlu:

Eto ati Igbaradi

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Aworan: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Awọn ilana Iṣiṣẹ

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Yọ ideri aabo kuro lati elekiturodu.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Nu elekitiroodu naa patapata.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Laasigbotitusita

This section addresses common issues related to electrode performance and how the storage solution can help.

IsoroOwun to le FaOjutu
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Orukọ ọja3M KCL Storage Soaking Solution
Nọmba awoṣeAI1107
BrandApera Instruments
Iwọn didun ohun kan8 Omi Ounce (isunmọ. 236 milimita)
KCL Concentration3M (3 mol/L)
Fọọmu NkanOmi
Package InformationIgo
Ọja Mefa6.3 x 1.97 x 2.36 inches
Iwọn Nkan9 iwon
Ilu isenbaleUSA

Alaye atilẹyin ọja

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webaaye tabi kan si atilẹyin alabara wọn taara.

Atilẹyin ati Olubasọrọ

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webojula:

www.aperainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Awọn iwe aṣẹ ti o jọmọ - AI1107

Ṣaajuview Apera SX811-SS Mita pH to šee gbe fun Idanwo Ounjẹ: Afọwọṣe ilana & Awọn pato
Iwe itọnisọna pipe ati awọn alaye imọ-ẹrọ fun Apera SX811-SS mita pH to ṣee gbe, ti a ṣe apẹrẹ fun idanwo ounjẹ deede. Kọ ẹkọ nipa awọn ẹya, isọdiwọn, iṣeto, ibaraẹnisọrọ USB, ati laasigbotitusita.
Ṣaajuview PH60Z-HT Smart pH Mita olumulo Afowoyi - Apera Instruments
Itọsọna olumulo fun Awọn ohun elo Apera PH60Z-HT Smart pH Mita, ṣe alaye awọn ẹya ara ẹrọ rẹ, iṣẹ ṣiṣe, isọdiwọn, itọju, ati laasigbotitusita fun iwọn otutu giga ati awọn solusan caustic.
Ṣaajuview PH60Z-PW Smart pH-Mita Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Smart pH-Mita. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen ni reinem Wasser.
Ṣaajuview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Ṣaajuview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.
Ṣaajuview APERA Instruments pH 4.00 Buffer Solution Safety Data Sheet
Safety Data Sheet (SDS) for APERA Instruments pH 4.00 Buffer Solution, providing essential information on identification, hazards, first aid, handling, storage, and regulatory compliance.