1. Ifihan
The Ohaus Defender 5000 Series multifunctional bench scale is engineered for demanding industrial and commercial applications, including production, packaging, inventory management, and shipping. This scale is designed to simplify complex tasks with its robust construction and advanced features.
Key features of the D52P50RQL5 model include:
- Awọn Ẹka Iwọn: Supports lb, oz, lb/oz, kg, g, metric tonnes, short ton, and custom units.
- Ifihan: Dot matrix LCD with white LED backlight for clear visibility.
- Iwọn ipilẹ: 18 inches x 18 inches.
- Iṣagbesori: Stainless steel front mount bracket with handle for the indicator.
- Ikole: Features a removable stainless steel weighing platform, a powder-coated steel base, and an aluminum load cell with silicon sealing.

This image shows the Ohaus Defender 5000 Low Profile Scale. It features a large, square stainless steel weighing platform and a separate digital indicator unit with a dot matrix LCD display, connected by a cable. The indicator unit is mounted on a bracket, positioned next to the platform. The Ohaus brand name is visible on the front of the platform, and 'Defender' is on the indicator unit.
2. Eto
Follow these steps to set up your Ohaus Defender 5000 scale:
- Ṣii silẹ: Carefully remove all components from the packaging. Verify that all parts are present: weighing platform, base, indicator unit, power adapter, and mounting bracket.
- Ibi: Place the scale base on a stable, level surface free from vibrations, drafts, and extreme temperature changes. Ensure adequate space around the scale for operation and maintenance.
- Àpéjọ Pẹpẹ: Gently place the stainless steel weighing platform onto the base. Ensure it sits securely and does not wobble.
- Indicator Mounting: Attach the indicator unit to the stainless steel front mount bracket. Position the bracket as desired for optimal viewing and operation. Connect the indicator cable to the appropriate port on the base.
- Asopọ agbara: Connect the power adapter to the indicator unit and then plug it into a suitable power outlet.
- Ìpele: Use the adjustable feet on the base to level the scale. Check the bubble level (if present) to ensure precise leveling.
3. Isẹ
This section outlines basic operating procedures for the Defender 5000 scale.
3.1 Titan / Pa a
- Lati mu agbara ṣiṣẹ, tẹ bọtini naa [TAN/PA] button on the indicator.
- Lati fi agbara si pipa, tẹ mọlẹ [TAN/PA] bọtini titi ti ifihan yoo wa ni pipa.
3.2 Ìwọ̀n Ìpìlẹ̀
- Ensure the scale is powered on and displays '0.00' (or similar zero reading). If not, press the [ZERO] bọtini.
- Fi pẹ̀lẹ́pẹ̀lẹ́ gbé ohun tí a fẹ́ wọ̀n sí àárín pẹpẹ ìwọ̀n náà.
- Wait for the display to stabilize. The stable weight will be shown on the LCD.
- Remove the item from the platform.
3.3 Taring (Removing Container Weight)
- Place an empty container onto the weighing platform.
- Tẹ awọn [TARE] button. The display will return to '0.00', indicating the container's weight has been tared out.
- Place the material to be weighed into the container. The display will show the net weight of the material.
- To clear the tare, remove the container and its contents, then press [TARE] lẹẹkansi.
3.4 Aṣayan Ẹyọ
To change the weighing unit (e.g., from pounds to kilograms), press the [UNIT] button. Each press will cycle through the available units (lb, oz, kg, g, etc.).
4. Itọju
Proper maintenance ensures the longevity and accuracy of your Ohaus Defender 5000 scale.
4.1 Ninu
- Always disconnect the scale from the power supply before cleaning.
- Lo asọ, damp cloth with a mild detergent to clean the stainless steel platform and powder-coated base.
- Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish and components.
- Do not spray liquids directly onto the indicator unit or base.
- Ensure all parts are dry before reconnecting power.
4.2 Idiwọn
Regular calibration is essential for maintaining weighing accuracy. Refer to the detailed calibration procedures in the full technical manual or contact Ohaus customer support for assistance. Calibration typically requires certified test weights.
5. Laasigbotitusita
Abala yii n pese awọn ojutu si awọn ọran ti o wọpọ ti o le ba pade.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Iwọn ko ni agbara lori | No power supply; faulty power adapter; loose connection | Ṣayẹwo asopọ okun agbara; rii daju pe iṣan jade jẹ iṣẹ-ṣiṣe; gbiyanju ohun ti nmu badọgba agbara ti o yatọ ti o ba wa. |
| Awọn kika ti ko pe | Scale not level; drafts or vibrations; calibration required; damaged load cell | Ensure scale is level; move scale to a stable environment; perform calibration; contact service if issue persists. |
| Display shows 'OVERLOAD' | Weight exceeds maximum capacity | Yọ iwuwo ti o pọ ju kuro lẹsẹkẹsẹ lati yago fun ibajẹ. |
| Display shows 'UNSTABLE' | Vibrations; unstable load; internal issue | Ensure stable environment; place load centrally and steadily; contact service if persistent. |
If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please contact Ohaus customer support.
6. Awọn pato
Detailed technical specifications for the Ohaus Defender 5000 Low Profile Scale D52P50RQL5:
- Awoṣe: D52P50RQL5
- Olupese: Ohous
- Awọn iwọn ọja: 40 x 27 x 10 inches
- Iwọn Ọja: 38 iwon
- Awọn Ẹka Iwọn: lb, oz, lb/oz, kg, g, metric tonnes, short ton, custom unit
- Ifihan: Dot matrix LCD with white LED backlight
- Iwọn ipilẹ: 18" x 18"
- Oke: Stainless Steel front mount bracket with handle
- Ikole: Stainless Steel Removable Weighing Platform, Powder-coated Steel Base, Aluminum Loadcell Silicon Sealed
7. Atilẹyin ọja ati Support
For information regarding the warranty period and terms for your Ohaus Defender 5000 scale, please refer to the warranty card included with your product or visit the official Ohaus website. Warranty details can vary by region and product.
For technical support, service, or to inquire about replacement parts, please contact Ohaus customer service directly. You can typically find contact information on the Ohaus webaaye tabi ni iwe ọja.
Ohaus Official Webojula: www.ohaus.com