Idec RH4B-UAC120V

RH4B-UAC120V Power Relay Instruction Manual

Model: RH4B-UAC120V | Brand: Idec

Ọrọ Iṣaaju

This manual provides essential information for the safe and effective use of the Idec RH4B-UAC120V Power Relay. This device is designed for reliable electrical switching applications, featuring a 4PDT contact configuration and operating on a 120VAC coil voltage. Please read this manual thoroughly before installation and operation.

Awọn iṣọra Aabo

Always observe the following safety precautions to prevent electric shock, fire, or damage to the product:

Eto ati fifi sori

The RH4B-UAC120V Power Relay is designed for socket mounting. Follow these general steps for installation:

  1. Iṣagbesori: Securely mount the appropriate relay socket (not included) in a stable location, typically on a DIN rail or panel.
  2. Asopọmọra: Connect the control circuit to the coil terminals and the load circuit to the contact terminals. Refer to the wiring diagram provided with your relay socket or system documentation for specific pin assignments. Ensure all connections are tight and secure.
  3. Fi sii: Carefully insert the RH4B-UAC120V relay into its socket, ensuring all pins align correctly with the socket terminals. Apply gentle, even pressure until the relay is fully seated.
  4. Ìmúdájú: Before applying power, double-check all wiring connections for correctness and ensure no loose strands or short circuits are present.
Idec RH4B-UAC120V Power Relay

Figure 1: Idec RH4B-UAC120V Power Relay. This image shows the compact design of the relay with its transparent casing, revealing the internal contacts and coil, and the multiple pins for socket connection at the base.

Awọn ilana Iṣiṣẹ

The RH4B-UAC120V Power Relay operates automatically based on the presence or absence of voltage across its coil terminals. It functions as a switch to control higher power circuits or to provide isolation between control and load circuits.

Ensure the load connected to the contacts does not exceed the 10 Amps current rating to prevent damage to the relay and connected equipment.

Itoju

The RH4B-UAC120V Power Relay is designed for long-term reliability with minimal maintenance. However, periodic inspection is recommended to ensure optimal performance and longevity.

Laasigbotitusita

If the RH4B-UAC120V Power Relay does not function as expected, consider the following common issues and solutions:

IsoroOwun to le FaOjutu
Relay does not energize (contacts do not switch)
  • No power to coil terminals.
  • Vol coil ti ko tọtage (not 120VAC).
  • Alailowaya tabi ti ko tọ onirin.
  • Ìsopọ̀ tí ó ti bàjẹ́.
  • Verify 120VAC supply to coil terminals.
  • Ṣayẹwo orisun agbara voltage.
  • Inspect and correct wiring connections.
  • Replace relay if coil is damaged.
Contacts do not switch reliably or chatter
  • Overload on contacts.
  • Excessive wear on contacts.
  • Coil voltage awọn iyipada.
  • Ensure load current is within 10A rating.
  • Replace relay if contacts are worn.
  • Stabilize coil power supply.
Relay gbóná ju bó ṣe yẹ lọ
  • Apọjutage applied to coil.
  • Overcurrent through contacts.
  • Afẹfẹ ti ko dara.
  • Ṣe àyẹ̀wò ìpele coiltage jẹ 120VAC.
  • Reduce load current or use a higher-rated relay.
  • Ensure adequate airflow around the relay.

If problems persist, consult a qualified electrician or contact Idec technical support.

Awọn pato

IwaIye
Nọmba awoṣeRH4B-UAC120V
BrandIdec
Olubasọrọ Iru4PDT (Four Pole Double Throw)
Ti isiyi Rating10 Amps
Coil Voltage120 folti AC
Ipo IsẹLaifọwọyi
OlupeseIDEC
Awọn iwọn (Isunmọ)27.5 x 41 x 42 mm

Atilẹyin ọja ati Support

For information regarding warranty coverage, technical support, or service, please refer to the official Idec website or contact your authorized Idec distributor. Keep your purchase receipt as proof of purchase.

Idec Official Webojula: https://us.idec.com/

Awọn iwe aṣẹ ti o jọmọ - RH4B-UAC120V

Ṣaajuview Àwọn Ìgbékalẹ̀ Àgbáyé IDEC RU Series: Àwọn Ẹ̀yà Ara Rẹ̀, Àwọn Ìlànà Pàtàkì, àti Àwọn Ìlò Rẹ̀
Ìtọ́sọ́nà pípéye sí àwọn ìtúnsọ kékeré IDEC RU Series, tí ó ṣàlàyé àwọn ẹ̀yà ara wọn, àwọn pàtó ìmọ̀-ẹ̀rọ, àwọn ìlà ìgbésí ayé iná mànàmáná, àwọn ìwọ̀n, àwọn nọ́mbà apá, àwọn ihò tó yẹ, àti àwọn ìṣọ́ra ààbò fún ìdáṣiṣẹ́ ilé-iṣẹ́.
Ṣaajuview IDEC YW Series Yipada & Awọn Imọlẹ Pilot - Katalogi Ọja Apejuwe
Ṣawari awọn IDEC YW Series of Ø22 ati Ø30 awọn iyipada ati awọn imole awaoko, pẹlu awọn iyipada idaduro pajawiri, awọn bọtini titari, awọn iyipada ti o yan, awọn bọtini yiyan bọtini, ati awọn imọlẹ awaoko. View awọn pato, awọn nọmba apakan, awọn iwọn, ati awọn ẹya ẹrọ.
Ṣaajuview Itọsọna Yiyan Iduro IDEC
Ìtọ́sọ́nà pípéye lórí bí a ṣe lè yan àwọn relays IDEC, tí ó bo oríṣiríṣi jara bíi RV8H, RJ, RH, RU, RR, RL, RY, RF, àti RSC solid-state relays. Ó ṣe àlàyé àwọn pàtó, àwọn ẹ̀yà ara, àti àwọn ìtọ́kasí fún àwọn ohun èlò ilé-iṣẹ́.
Ṣaajuview Àwọn Ìfàsẹ́yìn Agbára IDEC RF1V àti Àwọn Sockets Ìfàsẹ́yìn SF1V | Àwọn Ẹ̀yà Ìṣàbòsí
Ṣe àwárí àwọn Relays RF1V Force Guided Relays àti SF1V Relay Sockets ti IDEC, tí a ṣe fún ìkọ́lé àyíká ààbò tí ó rọrùn tí ó sì ṣeé gbẹ́kẹ̀lé. Àwọn ẹ̀yà ara rẹ̀ ní ìbámu EN50205, ìdáhùn kíákíá, àti ìdènà ìjamba.
Ṣaajuview IDEC SmartRelay FL1F: IoT-Ready Compact Programmable Relay
Ṣe àwárí IDEC SmartRelay FL1F, relay eto ti o wapọ ati kekere ti a ṣe apẹrẹ fun adaṣiṣẹ adaṣe, iṣakoso, ati abojuto latọna jijin. Iwe yii ṣe alaye awọn ẹya ara ẹrọ rẹ, awọn agbara I/O ti o gbooro, awọn ilana ibaraẹnisọrọ (Modbus TCP, MQTT), web iṣẹ́ olupin, àti àwọn ìlànà ìmọ̀-ẹ̀rọ tó péye.
Ṣaajuview IDEC XW7E-BS312PK Collector User Manual and Specifications
Comprehensive user manual and technical specifications for the IDEC XW7E-BS312PK Collector, including safety precautions, electrical ratings, dimensions, mounting, wiring, maintenance, and troubleshooting.