Idec RJ2S-CL-D12

Ìwé Ìtọ́sọ́nà Olùlò RJ2S-CL-D12 Electromechanical Relay

Model: RJ2S-CL-D12 | Brand: Idec

1. Ọja Ipariview

The Idec RJ2S-CL-D12 is an 8A DPDT (Double Pole Double Throw) electromechanical relay designed for general purpose switching applications. It operates on a 12VDC coil voltage and features a compact design suitable for various industrial electrical control systems. This relay is typically used for switching higher power circuits with a low power control signal, providing isolation between control and load circuits.

Idec RJ2S-CL-D12 Electromechanical Relay

Figure 1: Idec RJ2S-CL-D12 Electromechanical Relay. This image shows the compact, transparent yellow casing of the relay, revealing the internal coil and contacts, with the pin base visible at the bottom.

2. Alaye Aabo

Always observe the following safety precautions when installing, operating, or maintaining the relay:

3. Eto ati fifi sori

The RJ2S-CL-D12 relay is designed for socket mounting. Follow these steps for proper installation:

  1. Ge asopọ agbara: Before beginning, ensure that all power to the circuit where the relay will be installed is completely disconnected and locked out.
  2. Socket Selection: Use a compatible relay socket (e.g., Idec SY4S-05 or similar) that matches the relay's pin configuration.
  3. Mounting the Socket: Securely mount the relay socket to a DIN rail or panel using appropriate fasteners.
  4. Wiring the Socket: So iṣakoso voltage (12VDC) to the coil terminals of the socket. Refer to the socket's wiring diagram for correct polarity. Connect the load circuit wires to the appropriate contact terminals (common, normally open, normally closed) as required by your application. The DPDT configuration provides two independent sets of contacts.
  5. Inserting the Relay: Carefully align the relay pins with the corresponding holes in the socket. Gently push the relay into the socket until it is fully seated. Do not force the relay, as this may bend or damage the pins.
  6. Ìmúdájú: Double-check all wiring connections for correctness and security before restoring power.

4. Awọn ilana Iṣiṣẹ

The RJ2S-CL-D12 relay operates by energizing its coil, which then actuates the internal contacts to switch the connected load circuits.

5. Itọju

Electromechanical relays like the RJ2S-CL-D12 are generally low-maintenance devices. However, periodic inspection can help ensure reliable operation.

6. Laasigbotitusita

If the RJ2S-CL-D12 relay is not functioning as expected, consider the following troubleshooting steps:

IsoroOwun to le FaOjutu
Relay coil does not energize (no click, no indicator light)
  • No 12VDC power to coil terminals.
  • Vol coil ti ko tọtage (e.g., AC instead of DC, or wrong DC voltagati).
  • Loose or incorrect wiring to coil.
  • Ìsopọ̀ tí ó ti bàjẹ́.
  • Verify 12VDC supply at coil terminals with a multimeter.
  • Rii daju pe voltage and polarity are applied.
  • Check all coil wiring connections.
  • Replace relay if coil is confirmed damaged.
Relay energizes but load does not switch
  • Incorrect wiring of load contacts.
  • Open circuit in load path.
  • Load current exceeds relay contact rating.
  • Damaged contacts.
  • Review wiring diagram and verify load connections.
  • Check continuity of load circuit.
  • Ensure load current is within 8A rating.
  • Replace relay if contacts are damaged.
Relay buzzes or chatters
  • Insufficient or fluctuating coil voltage.
  • Vol coil ti ko tọtage type (e.g., AC ripple on DC).
  • Verify stable 12VDC supply to the coil.
  • Ensure power supply is clean DC.

7. Awọn pato

IwaIye
Nọmba awoṣeRJ2S-CL-D12
BrandIdec
Olubasọrọ IruDPDT (Ìjà Méjì Pólù Méjì)
Coil Voltage12VDC
Ti isiyi Rating8 Amps
Coist Resistance271 ohms
Awọn iwọn (Itosi.)28.8 x 12.7 x 33 mm
Ipo IsẹLaifọwọyi
OlupeseIDEC

8. Atilẹyin ọja ati Support

Specific warranty terms and conditions for the Idec RJ2S-CL-D12 relay are not provided in this manual. For detailed warranty information, technical support, or service inquiries, please contact Idec Corporation directly or refer to their official webojula.

You may also contact the authorized distributor or seller from whom you purchased the product for assistance.

Awọn iwe aṣẹ ti o jọmọ - RJ2S-CL-D12

Ṣaajuview Itọsọna Yiyan Iduro IDEC
Ìtọ́sọ́nà pípéye lórí bí a ṣe lè yan àwọn relays IDEC, tí ó bo oríṣiríṣi jara bíi RV8H, RJ, RH, RU, RR, RL, RY, RF, àti RSC solid-state relays. Ó ṣe àlàyé àwọn pàtó, àwọn ẹ̀yà ara, àti àwọn ìtọ́kasí fún àwọn ohun èlò ilé-iṣẹ́.
Ṣaajuview IDEC YW Series Yipada & Awọn Imọlẹ Pilot - Katalogi Ọja Apejuwe
Ṣawari awọn IDEC YW Series of Ø22 ati Ø30 awọn iyipada ati awọn imole awaoko, pẹlu awọn iyipada idaduro pajawiri, awọn bọtini titari, awọn iyipada ti o yan, awọn bọtini yiyan bọtini, ati awọn imọlẹ awaoko. View awọn pato, awọn nọmba apakan, awọn iwọn, ati awọn ẹya ẹrọ.
Ṣaajuview Àwọn Ìgbékalẹ̀ Àgbáyé IDEC RU Series: Àwọn Ẹ̀yà Ara Rẹ̀, Àwọn Ìlànà Pàtàkì, àti Àwọn Ìlò Rẹ̀
Ìtọ́sọ́nà pípéye sí àwọn ìtúnsọ kékeré IDEC RU Series, tí ó ṣàlàyé àwọn ẹ̀yà ara wọn, àwọn pàtó ìmọ̀-ẹ̀rọ, àwọn ìlà ìgbésí ayé iná mànàmáná, àwọn ìwọ̀n, àwọn nọ́mbà apá, àwọn ihò tó yẹ, àti àwọn ìṣọ́ra ààbò fún ìdáṣiṣẹ́ ilé-iṣẹ́.
Ṣaajuview Àwọn Ìfàsẹ́yìn Agbára IDEC RF1V àti Àwọn Sockets Ìfàsẹ́yìn SF1V | Àwọn Ẹ̀yà Ìṣàbòsí
Ṣe àwárí àwọn Relays RF1V Force Guided Relays àti SF1V Relay Sockets ti IDEC, tí a ṣe fún ìkọ́lé àyíká ààbò tí ó rọrùn tí ó sì ṣeé gbẹ́kẹ̀lé. Àwọn ẹ̀yà ara rẹ̀ ní ìbámu EN50205, ìdáhùn kíákíá, àti ìdènà ìjamba.
Ṣaajuview IDEC SmartRelay FL1F: IoT-Ready Compact Programmable Relay
Ṣe àwárí IDEC SmartRelay FL1F, relay eto ti o wapọ ati kekere ti a ṣe apẹrẹ fun adaṣiṣẹ adaṣe, iṣakoso, ati abojuto latọna jijin. Iwe yii ṣe alaye awọn ẹya ara ẹrọ rẹ, awọn agbara I/O ti o gbooro, awọn ilana ibaraẹnisọrọ (Modbus TCP, MQTT), web iṣẹ́ olupin, àti àwọn ìlànà ìmọ̀-ẹ̀rọ tó péye.
Ṣaajuview IDEC SmartRelay FL1F Series User's Manual
Comprehensive user's manual for the IDEC SmartRelay FL1F series, covering installation, wiring, programming, functions, and software for industrial logic modules. Includes technical specifications and operational guidelines.