The Vertiv Liebert GXT5-EBC72VRT2U is a hot-swappable, lead-acid UPS battery cabinet designed to extend the runtime of Liebert GXT5-3000LVRT2UXL UPS systems. This external battery cabinet enhances power availability by providing additional battery backup during power outages, ensuring continuous operation for critical loads. Its auto-detection feature simplifies installation, and it supports connectivity for up to six additional units for further runtime extension.
2. Alaye Aabo
Please read and understand all safety instructions before installing, operating, or maintaining this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ewu Itanna: Yi kuro ni ga voltage components. Do not open the cabinet or attempt to service it yourself. Refer all servicing to qualified personnel.
- Aabo Batiri: Batteries can present a risk of electrical shock and high short-circuit current. Observe the following precautions:
- Ma ṣe sọ awọn batiri sinu ina, nitori wọn le bu gbamu.
- Ma ṣe ṣi tabi ge awọn batiri ge. Electrolyte ti a tu silẹ jẹ ipalara si awọ ara ati oju. O le jẹ majele.
- Wọ roba ibọwọ ati orunkun.
- Ma ṣe gbe awọn irinṣẹ tabi awọn ẹya irin si oke awọn batiri.
- Ewu iwuwo: The unit is heavy (110 pounds). Use proper lifting techniques and equipment to prevent injury.
- Ayika fifi sori ẹrọ: Install the unit in a controlled environment, away from excessive heat, humidity, and dust.
3. Eto ati fifi sori
3.1 Package Awọn akoonu
Rii daju pe gbogbo awọn eroja wa:
- Vertiv Liebert GXT5-EBC72VRT2U External Battery Cabinet
- Fifi sori Itọsọna
- Mounting Hardware (for rack installation)
- Àwọn okùn ìsopọ̀ batiri
3.2 Fifi sori ti ara
The GXT5-EBC72VRT2U is a compact 2U rack-mounted unit. Ensure adequate ventilation space around the cabinet.
- Igbesoke agbeko: Secure the battery cabinet into a standard 19-inch equipment rack using the provided mounting hardware.
- Nsopọ si UPS: Connect the battery cabinet to the compatible Liebert GXT5-3000LVRT2UXL UPS system using the supplied battery connection cables. The unit features auto-detection connectivity for proper setup and configuration.
- Multiple EBCs: Up to 6 additional External Battery Cabinet units can be connected to the UPS for extended runtime.

olusin 3.2.1: Iwaju view of the Vertiv Liebert GXT5 External Battery Cabinet. This image shows the front panel with the Vertiv logo and ventilation grille.

olusin 3.2.2: Ẹyìn view of the Vertiv Liebert GXT5 External Battery Cabinet. This image highlights the battery connection ports and temperature sensor.
3.3 Ibẹrẹ Agbara-soke
Once physically installed and connected to the UPS, follow the UPS system's power-up procedure. The battery cabinet will be automatically detected and integrated into the UPS system's power management.
4. Awọn ilana Iṣiṣẹ
4.1 Isẹ deede
During normal operation, the UPS system, along with the connected external battery cabinet, continuously cleans and regulates power supplied to your IT loads. The UPS battery and the external battery cabinet are simultaneously charged to maintain full capacity.
4.2 Agbara Otage and Battery Backup
Ni iṣẹlẹ ti agbara otage or interruption, the Liebert GXT5 UPS system will seamlessly switch to battery power, drawing from both its internal batteries and the connected GXT5-EBC72VRT2U external battery cabinet. An alarm will typically sound on the UPS and any connected monitoring application, indicating the power status change.
The external battery cabinet significantly extends the runtime, providing more time to safely shut down equipment or for power to be restored.
4.3 Programmable Output Sockets (UPS Feature)
The Liebert GXT5 UPS, when paired with this battery cabinet, allows for prioritization of battery utilization through its programmable and controllable output sockets. This feature enables you to manage power distribution to critical and non-critical loads during a power event.
- Isakoṣo latọna jijin: Using the UPS monitoring application, you can remotely turn off socket groups connected to non-critical loads. This conserves battery power for essential equipment.
- Automated Shutdown: You can program the Liebert GXT5 UPS to automatically turn off specific socket groups at a pre-defined battery level. This ensures that critical loads receive power for a longer duration.
By intelligently managing power to different load groups, you can significantly increase the battery runtime for your most critical systems, providing more time for problem resolution or generator activation.
5. Itọju
Regular maintenance ensures the longevity and optimal performance of your external battery cabinet.
- Rirọpo Batiri: The batteries within the GXT5-EBC72VRT2U are hot-swappable, allowing for replacement without interrupting power to connected loads. Refer to the UPS system's manual for specific battery replacement procedures.
- Ninu: Keep the exterior of the cabinet clean and free from dust. Ensure ventilation openings are not obstructed. Use a dry, soft cloth for cleaning.
- Awọn sensọ Ayika: The unit includes external temperature compensation sensors that help extend battery life by optimizing charging based on ambient temperature. Ensure these sensors are not obstructed.
- Awọn iṣayẹwo deede: Periodically check the status indicators on your UPS and monitoring application for any alarms or warnings related to the battery cabinet.
6. Laasigbotitusita
Apá yìí fúnni ní ìtọ́sọ́nà fún àwọn ọ̀ràn tó wọ́pọ̀. Fún àwọn ìṣòro tó le koko, kan sí ìrànlọ́wọ́ ìmọ̀-ẹ̀rọ.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Battery cabinet not detected by UPS. | Loose or incorrect battery connection cables. | Verify that all battery connection cables are securely and correctly attached between the UPS and the battery cabinet. Ensure the auto-detection feature has completed its cycle. |
| Àkókò ìṣiṣẹ́ bátírì dínkù. | Aging batteries; excessive load; high ambient temperature. | Check battery health via UPS monitoring. Consider battery replacement if aged. Reduce non-critical loads. Ensure proper ventilation and operating temperature. |
| Alarm indicating battery fault. | Internal battery issue; connection problem. | Consult the UPS system's manual for specific alarm codes. If hot-swappable batteries are faulty, replace them. If the issue persists, contact Vertiv support. |
7. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | GXT5-EBC72VRT2U |
| Ọja Mefa | 21.3 x 16.9 x 3.3 inches |
| Iwọn Nkan | 110 iwon |
| Batiri Cell Tiwqn | Lead Acid (VRLA) |
| Voltage | 72 Volts |
| Ibamu | Liebert GXT5-3000LVRT2UXL (3000 VA) UPS systems |
| Fọọmù ifosiwewe | 2U Rack Mounted |
| Awọn ẹya ara ẹrọ | Hot-swappable, Auto-detection, External Temperature Compensation Sensors |
8. Atilẹyin ọja ati Support
The Vertiv Liebert GXT5-EBC72VRT2U External Battery Cabinet comes with a three-year factory warranty.
For technical support, service, or warranty claims, please contact Vertiv customer support. Refer to the official Vertiv website or the documentation included with your UPS system for contact information.