The Apera Instruments pH 4.00 Calibration Buffer Solution is a high-quality standard designed for accurate pH meter calibration. This 16 oz. bottle contains a solution traceable to NIST Standard Reference Materials (SRMs), ensuring reliability and precision in your measurements.

Awọn ẹya pataki pẹlu:

  • Yiye: Reported values are accurate to +/- 0.01 pH at 25 °C.
  • Iṣẹ́-ẹ̀rọ Dídára: Produced in an ISO 9001:2015 certified facility using high-purity reagents, deionized water, and certified analytical balances in a temperature-controlled environment.
  • Idanimọ: Color-coded for quick and easy identification.
  • Igbesi aye ipamọ: Double-sealed with a 2-year expiration from manufacture for an unopened bottle.

Eto ati Igbaradi

Before using the pH 4.00 calibration buffer solution, ensure your workspace is clean and free from contaminants. Follow these steps for optimal preparation:

  1. Inspect the Bottle: Verify the bottle is sealed and undamaged upon receipt. The solution is double-sealed for protection.
  2. Check Expiration Date: Locate the expiration date on the bottle label. Do not use the solution past its expiration date.
  3. Ìbámu Ojú otútù: Allow the buffer solution to reach the ambient temperature of your calibration environment before use. This is crucial for accurate calibration, as pH values are temperature-dependent.
  4. Gentle Mixing: Gently invert the bottle a few times to ensure homogeneity before opening. Avoid vigorous shaking, which can introduce air bubbles.
Iwaju view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle

Aworan 1: Iwaju view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, showing the label with product name, pH value, and volume.

Operating Instructions (Calibration Procedure)

This pH 4.00 buffer solution is used to calibrate pH meters. Always refer to your specific pH meter's instruction manual for detailed calibration steps. General steps for using this buffer are:

  1. Fi omi ṣan elekitirodu: Before immersing the electrode in the buffer solution, rinse it thoroughly with distilled or deionized water.
  2. Ẹ̀rọ ìtẹ̀mọ́lẹ̀: Submerge the pH electrode into a sufficient amount of pH 4.00 buffer solution. Ensure the electrode's sensing bulb and reference junction are fully immersed.
  3. Stabilize Reading: Allow the pH meter reading to stabilize. This may take a few moments.
  4. Ṣe iṣatunṣe iwọn: Initiate the calibration process on your pH meter according to its specific instructions for a 2-point or 3-point calibration, typically starting with pH 7.00, then pH 4.00, and optionally pH 10.00.
  5. Fi omi ṣan lẹhin lilo: After calibration with pH 4.00, rinse the electrode again with distilled or deionized water before proceeding to another buffer or sample.
Pada view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle with pH/Temperature Reference Chart

Aworan 2: Pada view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, displaying a pH/Temperature Reference Chart. This chart shows the precise pH value of the solution at various temperatures, which is critical for accurate calibration.

Itọju ati Ibi ipamọ

Proper maintenance and storage are essential to preserve the accuracy and shelf life of your pH 4.00 buffer solution:

  • Ibi ipamọ otutu: Store the bottle at room temperature, away from direct sunlight and extreme temperature fluctuations.
  • Keep Tightly Closed: Always recap the bottle tightly immediately after use to prevent evaporation and contamination.
  • Yago fun Kokoro: Never return used buffer solution to the original bottle. Pour out only the amount needed for calibration into a separate, clean beaker. Dispose of any unused portion from the beaker.
  • Igbesi aye ipamọ: The solution has a 2-year expiration from the date of manufacture when unopened. Once opened, its shelf life may be reduced depending on storage conditions and contamination.
Oke view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle showing the sealed cap

Aworan 3: Oke view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, highlighting the double-sealed cap for product integrity and protection.

Laasigbotitusita

If you encounter issues with your pH meter calibration using this buffer solution, consider the following:

  • Incorrect pH Reading: Ensure the buffer solution is at the same temperature as your pH meter's temperature compensation setting or the sample. Refer to the pH/Temperature Reference Chart on the bottle for accurate values at different temperatures.
  • Expired Solution: Check the expiration date. Expired buffer solutions can lead to inaccurate calibrations.
  • Kokoro: Verify that the buffer solution has not been contaminated by returning used solution to the bottle or by using unclean beakers/electrodes.
  • Electrode Issues: If problems persist, the issue might be with the pH electrode itself (e.g., dirty, dry, or aged). Refer to your pH meter's manual for electrode maintenance and troubleshooting.

Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Orukọ ọjapH 4.00 Calibration Buffer Solution
BrandApera Instruments
Nọmba awoṣeAI1107
Iwọn didun16 oz. (approximately 473 mL)
pH Value at 25°C4.00 +/- 0.01
Iwa kakiriNIST Standard Reference Materials (SRMs)
Standard iṣelọpọISO 9001:2015 certified facility with ISO 17025:2017 accreditation
FọọmuOmi
Package Mefa7.87 x 2.44 x 2.4 inches
Iwọn Nkan1.17 iwon
UPC810214030201

Support ati Resources

For additional support, documentation, or inquiries, please refer to the following resources:

  • MSDS Documents: Material Safety Data Sheets (MSDS) are available for download to provide detailed information on the product's properties and safety precautions.
  • Certificate of Analysis: A Certificate of Analysis can be obtained upon request, verifying the quality and specifications of your specific batch.
  • Olupese Webojula: Visit the official Apera Instruments website for comprehensive product information, FAQs, and contact details. www.apera.com
  • Itaja Amazon: Explore other Apera Instruments products and resources on their Amazon store page. Apera Instruments Amazon Store

Note: This product is from a small business brand. Your support is appreciated.

Awọn iwe aṣẹ ti o jọmọ - AI1107

Ṣaajuview APERA Instruments pH 4.00 Buffer Solution Safety Data Sheet
Safety Data Sheet (SDS) for APERA Instruments pH 4.00 Buffer Solution, providing essential information on identification, hazards, first aid, handling, storage, and regulatory compliance.
Ṣaajuview PH60Z-HT Smart pH Mita olumulo Afowoyi - Apera Instruments
Itọsọna olumulo fun Awọn ohun elo Apera PH60Z-HT Smart pH Mita, ṣe alaye awọn ẹya ara ẹrọ rẹ, iṣẹ ṣiṣe, isọdiwọn, itọju, ati laasigbotitusita fun iwọn otutu giga ati awọn solusan caustic.
Ṣaajuview Apera EC20 Apo Idanwo Conductivity: Ilana itọnisọna & Itọsọna
Iwe itọnisọna pipe fun Apera EC20 Oluṣeto Imudaniloju Apo. Kọ ẹkọ nipa iṣeto, isọdọtun, wiwọn adaṣe, awọn pato imọ-ẹrọ, ati alaye atilẹyin ọja.
Ṣaajuview Apera SX811-SS Mita pH to šee gbe fun Idanwo Ounjẹ: Afọwọṣe ilana & Awọn pato
Iwe itọnisọna pipe ati awọn alaye imọ-ẹrọ fun Apera SX811-SS mita pH to ṣee gbe, ti a ṣe apẹrẹ fun idanwo ounjẹ deede. Kọ ẹkọ nipa awọn ẹya, isọdiwọn, iṣeto, ibaraẹnisọrọ USB, ati laasigbotitusita.
Ṣaajuview Apera Instruments PH1 Iye pH Apo Olumulo Olumulo
Itọsọna olumulo fun Apera Instruments PH1 Apo Idanwo pH Iye. Pese awọn ilana alaye lori iṣeto, isọdiwọn, wiwọn, awọn eto paramita, awọn alaye imọ-ẹrọ, itọju iwadii, laasigbotitusita, rirọpo batiri, ati alaye atilẹyin ọja.
Ṣaajuview Apera Instruments Water Hardness Calibration Solution B1, B2, B3 Safety Data Sheet (SDS)
Safety Data Sheet (SDS) for Apera Instruments Water Hardness Calibration Solution B1, B2, B3, providing comprehensive information on identification, hazards, composition, first aid, firefighting, accidental release measures, handling, storage, exposure controls, physical and chemical properties, stability, reactivity, toxicological information, ecological information, disposal considerations, transport information, and regulatory information.