Ọrọ Iṣaaju
The Traceable Excursion-Trac Data Logger Thermometer is designed for precise temperature monitoring and data recording. This device simultaneously displays current, minimum, and maximum temperatures, and features a rolling memory for extensive data storage. It is equipped with a submersible probe and offers customizable alarm functions to ensure critical temperature conditions are maintained and recorded.

Image: The Traceable Excursion-Trac Data Logger Thermometer, showing its digital display and connected bullet probe.
Package Awọn akoonu
Rii daju pe gbogbo awọn nkan wa lori ṣiṣi silẹ:
- Traceable Excursion-Trac Data Logger Thermometer Unit
- Bullet Probe with 10-ft (3-m) Cable
- USB Flash Drive
- Flip-Open Stand
- Hook-and-Loop Strips
- Magnetic Strips
- Wall-Mount Receptacle
- Awọn batiri (ti a ti fi sii tẹlẹ tabi lọtọ)
- NIST-Traceable Calibration Certificate with Data
Ṣeto
- Fifi sori batiri: If batteries are not pre-installed, open the battery compartment on the back of the unit and insert the specified batteries, observing correct polarity.
- Asopọ Iwadi: Connect the bullet probe cable to the designated port on the thermometer unit. Ensure a secure connection.
- Ibi Ibẹrẹ: Position the thermometer unit using the flip-open stand for a benchtop, or utilize the hook-and-loop strips, magnetic strips, or wall-mount receptacle for secure placement. The 10-ft (3-m) submersible micro-cable allows the probe to be placed in the desired monitoring location, even permitting doors to close over the cable.
- Agbara Tan: Press the power button (if available) or ensure the unit is active. The display should illuminate, showing current temperature readings.
Awọn ilana Iṣiṣẹ
Isẹ ipilẹ
- Ifihan: The LCD simultaneously shows the current temperature, minimum recorded temperature (MIN), and maximum recorded temperature (MAX).
- Awọn ẹya: Use the 'UNITS' button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.
- Iranti View: The 'MEM VIEW' function allows review ti o ti fipamọ data.
Gbigbasilẹ Data
- The device features rolling memory, capable of retaining the most recent 525,600 temperature observations.
- Gbigbe Data: To transfer recorded data, insert the provided USB flash drive into the unit's USB port. The data will be saved as a CSV file, accessible on any computer without special software.
- Pa Iranti kuro: After downloading data and alarm events, the memory can be cleared to continue recording new data. Refer to the device's specific buttons (e.g., 'CLEAR') for this function.
Awọn iṣẹ itaniji
- The thermometer allows setting limits for and storing up to 10 unique alarm events.
- Eto Awọn itaniji: Use the 'ALARM' and 'SELECT/ADVANCE' buttons to set desired high and low temperature alarm thresholds.
- Smart-Alarm Function: The Smart-Alarm provides both visual and audible alerts. It continues to alert even if conditions return to the normal temperature range, ensuring that any excursion is noted.
- Itaniji ipalọlọ: An 'ALARM SILENCE' button is available to temporarily mute audible alerts.
Itoju
- Ninu: Pa ẹyọ kuro pẹlu ipolowoamp cloth. Do not submerge the main unit in water. The bullet probe is submersible and can be cleaned as needed.
- Rirọpo Batiri: When the battery indicator appears or the unit fails to power on, replace the batteries. Refer to the battery compartment for the correct battery type.
- Itọju Iwadii: Handle the probe and its cable with care to prevent damage. Avoid sharp bends or excessive pulling on the cable.
Laasigbotitusita
| Oro | Owun to le Fa | Ojutu |
|---|---|---|
| Unit does not power on or display is blank. | Awọn batiri ti o ku tabi aiṣedeede ti fi sori ẹrọ. | Ropo awọn batiri, aridaju ti o tọ polarity. |
| Awọn kika iwọn otutu ti ko pe. | Probe not properly connected or damaged. | Ensure probe is securely connected. Inspect probe and cable for visible damage. |
| Data not transferring to USB drive. | USB drive not properly inserted or full. | Re-insert USB drive. Ensure the drive has sufficient space. Try a different USB drive if available. |
| Alarm not sounding or not clearing. | Alarm settings incorrect or alarm silenced. | Verify alarm thresholds. Check if the alarm has been manually silenced. |
Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Nọmba awoṣe | Excursion-Trac |
| Iwọn otutu | –58 to 158 Degrees Fahrenheit (-50 to 70 Degrees Celsius) |
| Ipinnu | 0.01 ìyí |
| Yiye | 0.25 Iwọn Celsius |
| Agbara Wọle Data | 525,600 temperature observations (rolling memory) |
| Asopọmọra | USB (for CSV data transfer) |
| Ifihan Iru | LCD |
| Pataki Ẹya | Alarm (Smart-Alarm function) |
| Iwadi Iru | Bullet Probe, Submersible, 10-ft (3-m) cable |
| Ohun elo | Ṣiṣu |
| Itọju Ọja | Nu Nu |
| Ijẹrisi | NIST-traceable odiwọn |
Atilẹyin ati atilẹyin ọja
For technical assistance, product inquiries, or warranty information, please contact the manufacturer, Cole-Parmer, or visit their official website. Specific warranty details were not provided in the product data.
Olupese: COLE-PARMER
Brand: TACETACET.
Atilẹyin Ayelujara: www.coleparmer.com