Güde GSE 951

Ìwé Ìtọ́sọ́nà Olùlò Güde GSE 951 Ẹ̀rọ Gígé Ẹ̀rọ Gígé Ẹ̀rọ Gígé Ẹ̀rọ Méjì

Model: GSE 951 (Item No. 40726)

Ọrọ Iṣaaju

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Güde GSE 951 2-stroke gasoline generator. Please read these instructions carefully before operating the device and keep them for future reference. Proper use and maintenance will ensure the longevity and optimal performance of your generator.

Akiyesi pataki: This generator is not suitable for sensitive electronic devices such as laptops, smartphones, or music systems due to its power output characteristics.

Awọn Itọsọna Aabo

Máa tẹ̀lé àwọn ìlànà ààbò wọ̀nyí nígbà gbogbo láti dènà ìpalára àti ìbàjẹ́:

Close-up of the generator's power outlet and warning labels

Aworan: Power outlet and safety warnings on the Güde GSE 951 generator. The labels indicate important safety information regarding operation and refueling.

Ọja irinše

Familiarize yourself with the main components of your Güde GSE 951 generator:

Iwaju view of Güde GSE 951 generator with labeled components

Aworan: Iwaju view of the Güde GSE 951 generator highlighting key features such as the carrying handle, 2-stroke engine, recoil starter, and vibration-damping feet. Rated power is 720W, continuous power is 650W.

Close-up of the engine switch and choke lever on the generator

Aworan: Close-up of the engine switch and choke lever, essential controls for starting and stopping the generator.

Ṣeto

  1. Ṣii silẹ: Carefully remove the generator from its packaging. Check for any shipping damage.
  2. Ibi: Place the generator on a firm, level, and non-combustible surface. Ensure there is sufficient ventilation around the unit. Keep it away from walls, flammable materials, and other obstructions.
  3. Epo epo:
    • Ensure the engine is OFF and cool before refueling.
    • Use a 2-stroke fuel mixture with a ratio of 1:40 (e.g., 25 ml 2-stroke oil per 1 liter of gasoline).
    • Open the fuel cap and carefully pour the fuel mixture into the tank using a funnel to avoid spills.
    • Do not overfill. Leave some space for fuel expansion.
    • Securely close the fuel cap. Wipe up any spilled fuel immediately.
    Close-up of the fuel cap and tank opening on the generator

    Aworan: The fuel cap and opening for the 3.8-liter fuel tank. Always ensure the engine is off and cool before refueling with the correct 2-stroke mixture.

Awọn ilana Iṣiṣẹ

Bibẹrẹ Olupilẹṣẹ:

  1. Ensure the generator is on a stable surface and properly fueled.
  2. Ṣeto awọn engine yipada si awọn "ON" ipo.
  3. If the engine is cold, move the choke lever to the "CHOKE" position. For a warm engine, the choke may not be necessary.
  4. Firmly pull the recoil starter handle until the engine starts. Do not let the rope snap back; guide it gently.
  5. Once the engine starts, slowly move the choke lever back to the "RUN" position.
  6. Allow the engine to warm up for a few minutes before connecting any electrical devices.
Close-up of the recoil starter on the Güde GSE 951 generator

Aworan: The recoil starter mechanism, used for manually starting the generator's 2-stroke engine.

Awọn ẹrọ Asopọmọra:

Idaduro Generator:

  1. Ge gbogbo awọn ẹrọ ina kuro ninu ẹrọ ina.
  2. Set the engine switch to the "OFF" position.
  3. Allow the generator to cool down completely before storing or transporting.
Güde GSE 951 generator operating in a garden setting

Aworan: The Güde GSE 951 generator positioned on grass in a garden, demonstrating its portable nature for outdoor use.

Woman using a hedge trimmer powered by the Güde GSE 951 generator

Aworan: An teleample of the generator in use, powering a hedge trimmer for garden maintenance. This illustrates its suitability for various outdoor tools.

Itoju

Regular maintenance ensures the optimal performance and extends the lifespan of your generator. Always ensure the engine is off and cool before performing any maintenance.

Laasigbotitusita

IsoroOwun to le FaOjutu
Enjini ko bẹrẹKo si epo tabi adalu idana ti ko tọ
Engine yipada PA
Kò sí ìdènà nínú ẹ́ńjìnnì (ẹ̀rọ tútù)
Pọ́ọ̀gù iná náà ti bàjẹ́ tàbí ó ti bàjẹ́
Check fuel level and mixture ratio
Set engine switch to ON
Ṣiṣẹ́ choke fún ìbẹ̀rẹ̀ òtútù
Nu tabi ropo sipaki plug
Ko si iṣelọpọ agbaraApọju Idaabobo tripped
Connected device faulty
Asopọ alaimuṣinṣin
Reduce load, reset overload protection
Check connected device
Rii daju awọn asopọ to ni aabo
Engine nṣiṣẹ ibi tabi ibùsoIdọti air àlẹmọ
Adalu idana ti ko tọ
Clogged fuel line/carburetor
Alẹmọ afẹfẹ mimọ
Ensure correct 1:40 fuel mixture
Clean fuel system (professional service recommended)

If you encounter problems not listed here or if solutions do not resolve the issue, please contact Güde customer support.

Imọ ni pato

Ẹya ara ẹrọIye
AwoṣeGSE 951
Nọmba Awoṣe Nkan40726
O wujade Voltage230 V
Ijade lọwọlọwọ4 A
Igbohunsafẹfẹ50 Hz
Ti won won Agbara720 W
Agbara Tesiwaju650 W
Engine Iru2-ọpọlọ
Agbara ẹrọ1 kW / 1.36 HP
Nipo63 cm³
Epo Iru2-stroke mixture (Gasoline)
Apapọ Ipin1:40
Agbara ojò3.8 L
Operating Time (50% load)Titi di wakati 7.5
Bibẹrẹ SystemRecoil (Inversion) start
Kilasi Idaabobo (IP)23 m
Apọju IdaaboboBẹẹni
Ipele Agbara Ohun LWA95 dB
Awọn iwọn (L x W x H)370 x 325 x 370 mm
Apapọ iwuwo15.85 kg
Àwọ̀Dudu/bulu
Ohun eloṢiṣu
Niyanju LiloCamping, outdoor power needs

Atilẹyin ọja ati Support

Güde is committed to providing durable products and excellent customer service.

For specific warranty terms and to access support services, please refer to the official Güde webojula tabi kan si wọn onibara iṣẹ taara.