Gáàsì ìfọ́ 3028381

Immergas Victrix Zeus 25 kW Condensing Boiler

Awoṣe: 3028381 | Brand: Immergas

Ọja Pariview

The Immergas Victrix Zeus 25 kW is a high-efficiency condensing boiler designed for both heating and domestic hot water production. This model, identified by part number 3.028381, is engineered for energy efficiency, contributing to significant energy savings. Its compact design and advanced features make it a reliable choice for modern heating systems.

Immergas Victrix Zeus 25 kW Condensing Boiler

A iwaju-ti nkọju si view of the white Immergas Victrix Zeus 25 kW condensing boiler, showing its compact design and the control panel located at the bottom.

Awọn ẹya pataki:

  • Victrix Zeus condenser 25 kW capacity.
  • Designed for efficient heating and domestic hot water supply.
  • Low energy consumption due to energy-saving cycle.
  • Compact dimensions: 58 x 41 x 90 cm; 42 kg.
  • Nọmba apakan: 3.028381.

Eto ati fifi sori

Installation of the Immergas Victrix Zeus 25 kW condensing boiler must be performed by a qualified and certified professional in accordance with all local and national regulations and safety standards. Improper installation can lead to serious hazards, including gas leaks, carbon monoxide poisoning, fire, or electric shock.

Awọn iṣayẹwo fifi sori ẹrọ tẹlẹ:

  • Ensure the installation site meets all ventilation and clearance requirements.
  • Verify the gas supply type and pressure are compatible with the boiler specifications.
  • Confirm adequate electrical supply and grounding.
  • Check the integrity of the flue system and ensure proper condensate drainage.

Mounting and Connections:

  1. Securely mount the boiler to a suitable wall structure using appropriate fasteners.
  2. Connect the gas supply line, ensuring all connections are leak-free and tested.
  3. Connect the heating flow and return pipes, and the domestic hot water inlet and outlet.
  4. Install the condensate drain line with proper slope to a suitable discharge point.
  5. Connect the flue system according to manufacturer guidelines and local codes.
  6. Perform electrical wiring, connecting power supply and control wiring as per the wiring diagram provided in the full installation manual.

After installation, a qualified technician must perform a commissioning process to ensure safe and efficient operation.

Awọn ilana Iṣiṣẹ

The Immergas Victrix Zeus 25 kW boiler is designed for user-friendly operation. Familiarize yourself with the control panel before use.

Ibi iwaju alabujutoview:

  • Iboju ifihan: Shows current status, temperature, and error codes.
  • Heating Temperature Knob: Adjusts the central heating water temperature.
  • Domestic Hot Water (DHW) Temperature Knob: Adjusts the hot water temperature for taps and showers.
  • Mode Selector Button: Switches between heating only, DHW only, or heating + DHW modes.
  • Bọtini atunto: Used to reset the boiler after an error code appears.

Isẹ ipilẹ:

  1. Agbara Tan: Ensure the boiler is connected to the power supply and the main power switch is in the 'ON' position.
  2. Yan Ipo: Use the mode selector button to choose your desired operation (e.g., heating and hot water).
  3. Set Temperatures: Adjust the heating and DHW temperature knobs to your preferred settings. Recommended heating temperature is typically between 60-80°C, and DHW between 40-55°C.
  4. Titẹ Eto: Regularly check the system pressure gauge. It should typically be between 1.0 and 1.5 bar when the system is cold. If the pressure is too low, consult the full manual for instructions on repressurizing or contact a qualified technician.
  5. Paade: To turn off the boiler, switch the main power switch to the 'OFF' position. For extended periods of inactivity (e.g., summer), it is recommended to turn off the boiler and drain the system if there is a risk of freezing.

For advanced settings, timer programming, or external control integration, refer to the comprehensive user manual provided with the product.

Itoju

Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Immergas Victrix Zeus 25 kW boiler. All maintenance and servicing should be carried out by a qualified and certified heating engineer.

User Checks (Monthly/Quarterly):

  • Ayewo wiwo: Check for any visible leaks, corrosion, or unusual noises.
  • Ṣayẹwo titẹ: Monitor the system pressure gauge. It should remain within the recommended range (typically 1.0-1.5 bar when cold).
  • Afẹfẹ: Ensure that all ventilation openings around the boiler are clear and unobstructed.

Professional Servicing (Annually):

An annual service by a Gas Safe registered (or equivalent national standard) engineer is mandatory to maintain warranty validity and ensure safe operation. A typical service includes:

  • Cleaning of the heat exchanger and burner.
  • Checking and adjusting gas pressure.
  • Testing of safety devices and controls.
  • Inspection of the flue system for blockages or damage.
  • Checking and topping up the expansion vessel pressure.
  • Testing for carbon monoxide emissions.
  • General inspection of all components for wear and tear.

Keep a record of all service dates and any work performed.

Laasigbotitusita

This section provides guidance for common issues you might encounter. For complex problems or if you are unsure, always contact a qualified heating engineer.

IsoroOwun to le FaOjutu
Ko si igbona tabi omi gbonaLow system pressure; Boiler lockout/error code; Thermostat issue; No gas supply.Check pressure gauge (repressurize if low); Check display for error codes and try reset; Verify thermostat settings; Ensure gas supply is on. If problem persists, contact technician.
Boiler making unusual noises (e.g., banging, gurgling)Air in the system; Limescale build-up (kettling); Pump issue.Bleed radiators to remove air; For kettling or pump issues, contact a qualified engineer for inspection and power flushing if necessary.
Boiler leaking waterLoose connection; Faulty component (e.g., pump seal, pressure relief valve); Corrosion.Immediately turn off the boiler and water supply. Contact a qualified engineer for urgent repair.
Koodu aṣiṣe hanSpecific fault detected by the boiler's internal diagnostics.Note the error code. Refer to the full user manual for a list of error codes and their meanings. Try pressing the reset button. If the error persists, contact a qualified engineer, providing them with the error code.

Pataki: Never attempt to repair the boiler yourself if you are not qualified. Always prioritize safety and consult a professional.

Awọn pato

IwaIye
OlupeseImmergas
Nọmba apakan3.028381
Ọja Mefa58 x 41 x 90 cm
Iwọn Nkan42 kg
Nọmba awoṣe3028381
Àwọ̀Funfun
Iye awọn ohun kan ninu package1
Awọn batiri to wa?Rara
Awọn batiri nilo?Rara
ASINB07V9YC46N
Akọkọ Wa ỌjọOṣu Kẹta Ọjọ 12, Ọdun 2020

Atilẹyin ọja ati Support

For specific warranty terms and conditions, please refer to the documentation provided with your Immergas Victrix Zeus 25 kW boiler at the time of purchase. Typically, manufacturers offer a standard warranty period, which may be extended if the boiler is serviced annually by a qualified engineer.

Ilana Pada:

  • This product typically has a 30-day return policy for refund or replacement, subject to the seller's terms and conditions.

Atilẹyin Onibara:

If you require technical assistance, have questions about your boiler's operation, or need to schedule a service, please contact Immergas customer support or your authorized Immergas dealer. Ensure you have your boiler's model number (3028381) and serial number ready when contacting support.

For professional installation and servicing, always choose a certified and reputable heating engineer.

Awọn iwe aṣẹ ti o jọmọ - 3028381

Ṣaajuview Immergas Victrix Zeus Superior 25/30/35 olumulo Afowoyi
Iwe afọwọkọ olumulo pipe fun Immergas Victrix Zeus Superior 25/30/35, fifi sori ẹrọ, iṣẹ ṣiṣe, itọju, ati data imọ-ẹrọ. Itọsọna pataki fun awọn fifi sori ẹrọ, awọn olumulo, ati awọn onimọ-ẹrọ itọju.
Ṣaajuview Immergas Victrix Zeus Superior 25-30-35 olumulo ká Afowoyi
Iwe afọwọṣe olumulo pipe fun Immergas Victrix Zeus Superior 25-30-35 igbomikana, fifi sori ẹrọ, iṣẹ ṣiṣe, itọju, data imọ-ẹrọ, ati laasigbotitusita.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Immergas Victrix Pro V2 35/55/60/68/80 EU: Fífi sori ẹrọ, ṣíṣiṣẹ́, àti ìtọ́jú
Ìwé ìtọ́ni tó péye fún ìlò fún ìgbóná omi ìgbóná Immergas Victrix Pro V2 35/55/60/68/80 EU. Ó ní àwọn ìlànà ààbò, ìṣiṣẹ́, ìtọ́jú, àti àwọn ìlànà ìmọ̀-ẹ̀rọ fún iṣẹ́ tó dára jùlọ àti pípẹ́.
Ṣaajuview Immergas Victrix Zeus Superior 25/30/35 olumulo Afowoyi
Ìwé ìtọ́ni tó péye yìí fún wa ní àwọn ìtọ́ni tó kún rẹ́rẹ́ nípa bí a ṣe lè fi sori ẹ̀rọ, bí a ṣe ń ṣiṣẹ́, àti bí a ṣe ń tọ́jú ẹ̀rọ Immergas Victrix Zeus Superior 25/30/35 condensing boiler, èyí tó máa ń mú kí iṣẹ́ wa dára sí i, kí ó sì pẹ́ tó.
Ṣaajuview Ìwé Ìtọ́sọ́nà Olùlò Immergas VICTRIX OMNIA: Ìtọ́sọ́nà Ìfisílé, Lílò, àti Ìtọ́jú
Ìwé ìtọ́ni tó péye fún ìlò fún ìgbóná omi ìfọ́ Immergas VICTRIX OMNIA. Ó ní àwọn ìtọ́ni lórí ìfisílé, àwọn ìlànà ìṣiṣẹ́, àwọn ìlànà ìtọ́jú, àwọn ìlànà ìmọ̀-ẹ̀rọ, àti ìṣòro fún iṣẹ́ àti ààbò tó dára jùlọ.
Ṣaajuview Immergas VICTRIX PRO V2 EU: Apoti Imọ-ẹrọ Ipilẹ Agbara giga
Iwe imọ-ẹrọ pipe fun Immergas VICTRIX PRO V2 EU jara ti agbara giga, awọn igbomikana condensing ti ogiri. Awọn alaye ni pato, awọn ẹya ara ẹrọ, awọn awoṣe (35-180 EU), awọn aṣayan fifi sori ẹrọ, awọn ẹya ẹrọ, ati data imọ-ẹrọ fun awọn solusan alapapo daradara.