ELIWELL RCS3UDTX20700

ELIWELL EWRC 500 NT HACCP Electronic Controller User Manual

Model: RCS3UDTX20700

1. Ifihan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the ELIWELL EWRC 500 NT HACCP Electronic Controller, Model RCS3UDTX20700. This device is designed for precise temperature regulation in industrial and commercial applications, particularly those requiring HACCP compliance. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

2. Alaye Aabo

Nigbagbogbo ṣe akiyesi awọn iṣọra aabo wọnyi:

3. Ọja Ipariview

The ELIWELL EWRC 500 NT is an advanced electronic controller featuring a digital display and intuitive button interface for easy parameter adjustment and monitoring. It is specifically designed for applications requiring HACCP protocol adherence.

ELIWELL EWRC 500 NT HACCP Electronic Controller front view

olusin 3.1: Iwaju view of the ELIWELL EWRC 500 NT HACCP Electronic Controller.

This image displays the front panel of the ELIWELL EWRC 500 NT HACCP Electronic Controller. The device is housed in a light grey, rectangular enclosure. The front panel features a dark grey rectangular display area with a digital readout, likely showing temperature or operational status. Below the display, the word "COLDFACE" is visible. To the right of the display, there are several control buttons arranged vertically. From top to bottom, these include: an "ESC" button with a snowflake icon, a "SET" button, a button with a light bulb icon, an "AUX" button with a down arrow, and an orange circular power button with a vertical line and circle icon. Above the "AUX" button, there is an up arrow button with a fan icon. The "eliwell" brand logo is visible in the upper left corner of the dark grey display area. The overall design suggests a robust and functional industrial control unit.

4. fifi sori

4.1 Iṣagbesori

The controller is designed for panel mounting with dimensions of 213x318mm. Ensure adequate ventilation around the unit to prevent overheating. Secure the controller using the provided mounting clips or screws, ensuring a snug fit to prevent vibration.

4.2 Onirin

All wiring must comply with local and national electrical codes. Use appropriate gauge wires for the power supply and load connections. Refer to the wiring diagram below for correct terminal connections.

Note: A detailed wiring diagram is typically provided on the device itself or in a separate technical sheet. For specific terminal assignments, consult the product's technical documentation.

Awọn Itọsọna Wire Gbogboogbo:

5. Eto

After successful installation and wiring, proceed with the initial setup:

  1. Agbara Tan: Apply power to the controller. The display will illuminate, and the unit will perform a self-test.
  2. Ifihan akọkọ: The display will typically show the current temperature reading from the primary probe.
  3. Accessing Parameters: Tẹ mọlẹ SET button for a few seconds to enter the parameter configuration menu.
  4. Lilọ kiri: Lo awọn Up ati Isalẹ arrow buttons to scroll through parameters.
  5. Ṣíṣàtúnṣe Àwọn Ìwọ̀n: Tẹ SET to select a parameter, use Up/Isalẹ lati yi iye rẹ pada, lẹhinna tẹ SET lẹẹkansi lati jẹrisi.
  6. Ijade Akojọ: Tẹ awọn ESC button to exit the parameter menu and return to the main display.

6. Awọn ilana Iṣiṣẹ

6.1 Ipilẹ isẹ

Once configured, the controller operates automatically based on the set parameters. The main display continuously shows the measured temperature.

6.2 Parameter Configuration (Advanced)

The EWRC 500 NT offers a wide range of configurable parameters to fine-tune its operation. These include setpoints, differentials, defrost cycles, alarm thresholds, and probe calibration. Access these parameters as described in the "Setup" section.

Consult the detailed parameter list in the full technical manual for specific codes and their functions. Incorrect parameter settings can lead to improper operation or damage.

7. Itọju

Regular maintenance ensures the longevity and accuracy of your controller.

All internal maintenance or repairs should only be performed by authorized service personnel.

8. Laasigbotitusita

Apá yìí ń pèsè àwọn ìdáhùn sí àwọn ìṣòro tó wọ́pọ̀. Fún àwọn ìṣòro tí a kò kọ síbí, kan si olùrànlọ́wọ́ ìmọ̀-ẹ̀rọ.

IsoroOwun to le FaOjutu
Ifihan jẹ òfoKo si ipese agbara; Asopọmọra ti ko tọ; Fiusi ti fẹ.Check power connections; Verify wiring against diagram; Replace fuse if necessary.
Kika iwọn otutu ko peFaulty probe; Incorrect probe type selected; Probe not properly installed.Check probe connection; Verify probe type in parameters; Reinstall probe.
Controller not switching loadIncorrect setpoint/differential; Relay fault; Wiring issue to load.Adjust parameters; Check load wiring; Contact service if relay is faulty.
Koodu aṣiṣe hanSpecific system fault (e.g., probe error, memory error).Refer to the full technical manual for specific error code meanings and remedies.

9. Awọn pato

Ẹya ara ẹrọẸ̀kúnrẹ́rẹ́
AwoṣeEWRC 500 NT HACCP (RCS3UDTX20700)
BrandELIWELL
Ibi ti ina elekitiriki ti nwa230 V AC
Awọn iwọn fifi sori ẹrọ213 x 318 mm (Panel Mount)
Ohun eloElectronic Temperature Regulation, HACCP Compliant
Olupese Reference4251759903357

10. Atilẹyin ọja ati Support

For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your distributor. Technical support can be obtained through the manufacturer or authorized service centers.

Olupese: Gastroteileshop

ASIN: B07Z5LXQWH

Awọn iwe aṣẹ ti o jọmọ - RCS3UDTX20700

Ṣaajuview Eliwell EWRC 300/500 NT Quick Bẹrẹ Itọsọna
Itọsọna ibẹrẹ iyara fun Eliwell EWRC 300/500 awọn olutona jara NT, ti a ṣe apẹrẹ fun aimi ati awọn yara tutu tutu. Iwe yii n pese alaye pataki lori fifi sori ẹrọ, lilọ kiri, awọn asopọ itanna, ati wiwo olumulo.
Ṣaajuview Eliwell Energy ST 500 Electronic Controllers for Air-Conditioning - User Manual
User manual for the Eliwell Energy ST 500, a range of electronic controllers designed for centralized air-conditioning units. Details features, configuration, operation, and technical specifications for HVAC systems.
Ṣaajuview Eliwell ICPlus 915 : Contrôleur Électronique de Température
Manuel technique pour le contrôleur électronique Eliwell ICPlus 915. Découvrez ses caractéristiques, spécifications, options de configuration et guides d'installation pour une régulation de température précise.
Ṣaajuview Eliwell AIR User Manual: Configuration, Monitoring, and Cloud Management for Refrigeration Systems
This comprehensive user manual guides users through the Eliwell AIR system, including the EW AIR EDGE gateway, Eliwell AIR APP, and Eliwell AIR Cloud platform. Learn how to configure, monitor, and manage refrigeration systems efficiently and securely.
Ṣaajuview Eliwell Dongle BTLE 5.0 AIR: Afọwọṣe olumulo Module Alailowaya HACCP
Itọsọna olumulo fun Eliwell Dongle BTLE 5.0 AIR, module alailowaya fun ibojuwo HACCP. Awọn aabo aabo, data imọ-ẹrọ, fifi sori ẹrọ, sisopọ, ati laasigbotitusita.
Ṣaajuview Eliwell ID 974 Itanna Controllers fun Fi agbara mu Air firiji Units - olumulo Afowoyi
Iwe yii n pese alaye okeerẹ lori Eliwell ID 974 oluṣakoso itanna, pẹlu wiwo olumulo, siseto, awọn iwadii aisan, fifi sori ẹrọ, data imọ-ẹrọ, ati awọn aworan onirin fun awọn iwọn itutu afẹfẹ fi agbara mu.