1. Ifihan
This manual provides detailed instructions for the safe and effective operation of the ANENG M20 Digital Multimeter. The M20 is a portable, battery-powered instrument designed for measuring various electrical parameters, including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, and continuity. It features a 6000-count LCD with backlight and automatic polarity display.
2. Alaye Aabo
Ikilọ: To avoid possible electric shock, fire, or personal injury, please read all safety information before using the product.
- Rí i dájú pé multimeter náà wà ní iṣẹ́ àti ìwọ̀n tó yẹ kí o tó ṣe àwọn ìwọ̀n.
- Maa ko waye voltage or current that exceeds the maximum rated values for the multimeter.
- Ṣọra pupọ nigbati o ba n ṣiṣẹ pẹlu voltages loke 30V AC RMS, 42V tente oke, tabi 60V DC. Awọn wọnyi ni voltages duro a mọnamọna ewu.
- Ṣayẹwo awọn itọsọna idanwo fun idabobo ti o bajẹ tabi irin ti o farahan ṣaaju lilo. Rọpo ti o ba bajẹ.
- Má ṣe lo multimeter náà bí ó bá dàbí pé ó ti bàjẹ́ tàbí tí àpótí náà bá ṣí sílẹ̀.
- Yọ awọn itọsọna idanwo kuro ninu Circuit ṣaaju ki o to yi awọn iṣẹ tabi awọn sakani pada.
- Rọpo awọn batiri nigbati ifihan batiri kekere ba han lati rii daju pe o peye awọn kika.
- Tẹle awọn koodu aabo agbegbe ati ti orilẹ-ede.
3. Awọn ẹya ara ẹrọ Ọja ati Loriview
The ANENG M20 Digital Multimeter is equipped with several features for versatile electrical testing.
- Ifihan: Liquid Crystal Display (LCD) with backlight.
- Ifihan ti o pọju: 6000 counts, automatic polarity display.
- Ọna Wiwọn: Double integral A/D conversion.
- SampOṣuwọn ling: Nǹkan bí ìgbà mẹ́ta fún ìṣẹ́jú-àáyá kan.
- Itọkasi iwọn apọju: "OL" symbol displayed.
- Kekere Voltage Itọkasi: Battery symbol appears.
- Agbara Aifọwọyi Paa: The device will power off after a period of inactivity to conserve battery.
- RMS otitọ: Ó ń pèsè àwọn ìkà tó péye fún àwọn ìgbì omi tí kì í ṣe sinusoidal.
- Non-Olubasọrọ Voltage (NCV) Iwari: Fun wiwa AC voltage lai taara olubasọrọ.

Nọmba 3.1: Iwaju view of the ANENG M20 Digital Multimeter, showing the LCD display, function dial, and input jacks.

Nọmba 3.2: The ANENG M20 Digital Multimeter package contents, including the multimeter, test leads, and user manual.
4. Eto ati Batiri sori
The ANENG M20 Multimeter requires AAA 1.5V batteries for operation.
- Ensure the multimeter is powered off and disconnect any test leads.
- Wa yara batiri ni ẹhin ẹrọ naa.
- Lo screwdriver lati ṣii ideri iyẹwu batiri naa.
- Insert two AAA 1.5V batteries, observing the correct polarity (+ and -).
- Rọpo ideri kompaktimenti batiri ki o ni aabo pẹlu dabaru.

Nọmba 4.1: Ẹyìn view of the ANENG M20 Digital Multimeter, showing the battery compartment cover and integrated kickstand.
5. Awọn ilana Iṣiṣẹ
This section details how to use the ANENG M20 for various measurements.
5.1. Gbogbogbo isẹ
- Titan/Apapa: Rotate the function dial from "OFF" to any desired measurement function to power on. Rotate back to "OFF" to power off.
- Aṣayan iṣẹ-ṣiṣe: Turn the rotary dial to select the desired measurement function (e.g., V~ for AC Voltage, V- fún DC Voltage, Ω fún Àtakò).
- Aṣayan Ibiti: The multimeter typically operates in auto-ranging mode. For manual range selection (if available), press the "RANGE" button.
- Idaduro data: Tẹ bọtini "DÍDÁ" lati di kika lọwọlọwọ lori ifihan naa. Tẹ lẹẹkansi lati tu silẹ.
- Imọlẹ ẹhin: The backlight can be activated for better visibility in low-light conditions. Refer to the specific button for backlight control (often integrated with "HOLD" or "SELECT").

Nọmba 5.1: Igun view of the multimeter, highlighting the function dial and control buttons.
5.2. Measuring Voltage (AC/DC)
- Insert the red test lead into the "VΩHzmA" jack and the black test lead into the "COM" jack.
- Rotate the function dial to the "V~" position for AC voltage tàbí "V-" fún DC voltage.
- So awọn itọsọna idanwo ni afiwe si Circuit tabi paati ti o fẹ lati wiwọn.
- Ka voltage iye lori LCD.
5.3. Measuring Current (AC/DC)
Iṣọra: Always connect the multimeter in series with the circuit when measuring current. Never connect it in parallel to a voltage orisun.
- For currents up to 600mA, insert the red test lead into the "VΩHzmA" jack. For currents up to 10A, insert the red test lead into the "10A" jack. The black test lead always goes into the "COM" jack.
- Rotate the function dial to the "A~" position for AC current or "A-" for DC current.
- Open the circuit where you want to measure current and connect the test leads in series.
- Ka awọn ti isiyi iye lori LCD.

Nọmba 5.2: Sun mo tipetipe view of the input jacks: 10A, COM, and VΩHzmA, with safety ratings.
5.4. Ìwọ̀n Àìdádúró (Ω)
- Insert the red test lead into the "VΩHzmA" jack and the black test lead into the "COM" jack.
- Rotate the function dial to the "Ω" position.
- Rí i dájú pé agbára ìṣiṣẹ́ tàbí ohun èlò náà ti dínkù kí o tó wọn agbára ìdènà.
- So awọn itọsọna idanwo kọja paati naa.
- Ka iye resistance lori LCD naa.
5.5. Igbeyewo Ilọsiwaju
- Insert the red test lead into the "VΩHzmA" jack and the black test lead into the "COM" jack.
- Rotate the function dial to the continuity symbol (often shared with diode or resistance).
- So awọn itọsọna idanwo kọja Circuit tabi paati.
- A continuous beep indicates a low resistance path (continuity). The display will show the resistance value.
5.6. Diode igbeyewo
- Insert the red test lead into the "VΩHzmA" jack and the black test lead into the "COM" jack.
- Rotate the function dial to the diode symbol (often shared with continuity).
- So asiwaju igbeyewo pupa pọ si anode ati asiwaju idanwo dudu si cathode ti diode.
- Awọn àpapọ yoo fi awọn siwaju voltagìsàlẹ̀ e. Yí àwọn ìtọ́sọ́nà padà; ìṣàfihàn ṣíṣí (OL) tọ́ka sí diode tó dára.
5.7. Non-olubasọrọ Voltage (NCV) erin
- Yi ipe iṣẹ pada si ipo "NCV".
- Move the top part of the multimeter near a live AC voltage source (e.g., an electrical outlet or wire).
- The multimeter will emit an audible beep and/or flash an indicator light when AC voltage ti ri.

Nọmba 5.3: Apa view of the multimeter, showing the NCV sensor area.
6. Itọju
- Ninu: Pa ọran naa pẹlu ipolowoamp asọ ati ìwọnba detergent. Maṣe lo awọn abrasives tabi awọn nkan ti a nfo.
- Rirọpo Batiri: Replace batteries promptly when the low battery indicator appears. Refer to Section 4 for instructions.
- Rirọpo Fuse: If the current measurement function stops working, the fuse may need replacement. This should only be performed by qualified personnel. Ensure the replacement fuse matches the specified rating (e.g., 600mA/1000V for mA range, 10A/600V for 10A range).
- Ibi ipamọ: If the multimeter is not used for an extended period, remove the batteries to prevent leakage. Store in a cool, dry place.
7. Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Multimeter ko ni agbara. | Awọn batiri ti o ku tabi ti ko tọ ti fi sori ẹrọ. | Ṣayẹwo polarity batiri tabi ropo awọn batiri. |
| "OL" tí a fi hàn nígbà tí a bá ń wọn nǹkan. | Àpọ̀jù tàbí ṣíṣí kiri. | Ensure the measurement range is appropriate or check for an open circuit. |
| Awọn kika ti ko pe. | Low battery, incorrect range, or external interference. | Replace batteries, select appropriate range, or move away from strong electromagnetic fields. |
| Iwọn lọwọlọwọ ko ṣiṣẹ. | Fiusi ti fẹ. | Rọpo fiusi (wo apakan Itọju). |
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Ifihan | LCD, 6000 awọn iṣiro |
| Ọna wiwọn | Iyipada A/D ilọpo meji |
| SampOṣuwọn ling | Isunmọ. 3 igba / iṣẹju-aaya |
| Overrange Atọka | "OL" |
| Kekere Voltage Itọkasi | Aami batiri |
| Ayika Ṣiṣẹ | 0°C to 40°C, relative humidity < 80% |
| Ibi ti ina elekitiriki ti nwa | Awọn batiri 2 x AAA 1.5V (ko si ninu wọn) |
| Awọn iwọn (LWH) | 142mm x 70mm x 32mm |
| Aabo Rating | CAT IV 600V, CAT III 1000V (implied from image) |
| RMS otitọ | Bẹẹni |
| Non-Olubasọrọ Voltage (NCV) | Bẹẹni |
9. Atilẹyin ọja ati Support
Information regarding product warranty and customer support is not available in the provided product details. Please refer to the documentation included with your purchase or contact the seller directly for warranty claims and technical assistance.