Ọrọ Iṣaaju
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Everbilt 1/2 HP Submersible Aluminum Sump Pump. Please read all instructions carefully before use to ensure proper function and to prevent injury or damage.
Alaye Aabo
IKILO: Always disconnect power before servicing or performing any maintenance on the pump.
IJAMBA: Ewu ti ina-mọnamọna. Yi fifa soke ti wa ni ipese pẹlu grounding adaorin ati grounding-Iru asomọ plug. Lati din eewu ina-mọnamọna ku, rii daju pe o ti sopọ si ilẹ daradara nikan, gbigba iru-ilẹ.
- Ma ṣe ṣiṣẹ fifa soke ti okun tabi plug ba bajẹ.
- Rii daju pe a gbe fifa soke sori iduro, ipele ipele.
- Do not pump flammable or corrosive liquids.
- Pa awọn ọmọde ati awọn ẹranko mọ kuro ninu fifa ẹrọ ti n ṣiṣẹ.
- Wear appropriate personal protective equipment (PPE) when handling the pump.
- This pump is designed for clear water only.
Ọja Pariview
The Everbilt 1/2 HP Submersible Sump Pump is designed for efficient water removal from sump basins. It features an aluminum motor housing for effective cooling and a tethered float switch for automatic operation.
Nọmba 1: Everbilt 1/2 HP Submersible Aluminum Sump Pump. This image shows the black pump unit with its tethered float switch, power cord, and 1-1/2 inch FNPT discharge port. The Everbilt logo is visible on the side of the pump body.
Awọn ẹya pataki:
- Aluminum motor housing for efficient motor cooling.
- Continuous duty, efficient 115-Volt PSC motor for lower carbon footprint; higher efficiency using less energy to operate.
- 8.25 ft. cord length.
- Submersible for quiet operation.
- 1-1/2 in. FNPT discharge.
- Semi-open thermoplastic impeller passes 3/8 in. solids.
- Gbona apọju Idaabobo.
Eto ati fifi sori
- Sump Basin Igbaradi: Ensure your sump basin has a minimum diameter of 18 inches to accommodate the tethered float switch. Clean the basin of any debris or obstructions.
- Ibi: Place the pump on a solid, level surface at the bottom of the sump basin. Ensure the pump is stable and will not tip over during operation.
- Asopọ Paipu Isunjade: Connect a 1-1/2 inch FNPT (Female National Pipe Thread) discharge pipe to the pump's outlet. It is recommended to use a check valve in the discharge line to prevent water from flowing back into the sump basin when the pump turns off.
- Àtúnṣe Ìyípadà Lílefó: The tethered float switch controls the pump's on/off cycles. Adjust the tether length to set the desired "on" and "off" water levels. Ensure the float can move freely without obstruction within the sump basin. The switch-on height is approximately 11.81 inches and switch-off height is approximately 3.94 inches, but can be adjusted by tether length.
- Asopọ agbara: Plug the pump's 8.25 ft. power cord into a properly grounded 115-Volt AC outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety.
- Iṣiṣẹ Idanwo: Kún omi náà basin with water to activate the float switch and ensure the pump turns on and discharges water correctly. Allow the water level to drop to verify the pump turns off automatically.
Awọn ilana Iṣiṣẹ
The Everbilt 1/2 HP Submersible Sump Pump operates automatically via its tethered float switch. Once properly installed and connected to power, the pump will activate when the water level rises to the "on" point and deactivate when the water level drops to the "off" point.
- Isẹ aladaaṣe: The pump is designed for continuous duty and will cycle on and off as needed based on the water level in the sump basin.
- Àtúnṣe pẹ̀lú ọwọ́ (tí ó bá wúlò): While primarily automatic, some installations may allow for manual operation by lifting the float switch. Refer to your specific setup for manual control options.
- Abojuto: Lojoojumọ ṣayẹwo sump basin and pump operation, especially during heavy rainfall, to ensure it is functioning correctly.
Itoju
Regular maintenance ensures the longevity and reliable operation of your sump pump.
- Ge Agbara: Máa yọ ẹ̀rọ fifa omi kúrò nínú orísun agbára kí o tó ṣe àtúnṣe èyíkéyìí.
- Clean Sump Basin: Periodically remove any debris, dirt, or sediment from the sump basin that could interfere with pump operation or float switch movement.
- Ṣe ayẹwo Impeller: Check the pump's impeller for any clogs or damage. The semi-open thermoplastic impeller is designed to pass 3/8 inch solids, but larger debris can cause issues.
- Ṣàyẹ̀wò Yíyípadà Líle: Ensure the tethered float switch moves freely and is not obstructed by wires, pipes, or debris.
- Ṣayẹwo okun agbara: Examine the power cord for any signs of wear, cuts, or damage. Replace if necessary.
- Igba otutu (ti o ba wulo): If the pump is in an area subject to freezing temperatures and will not be used, remove it from the basin, clean it, and store it in a dry, warm place.
Laasigbotitusita
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Fifa ko tan. | No power; tripped circuit breaker/GFCI; float switch obstructed or faulty; motor thermal overload. | Check power connection; reset breaker/GFCI; clear float switch path; allow motor to cool down. |
| Fifa gbalaye continuously. | Switi omi tí ó dúró ní ipò "tí ó wà"; ṣàyẹ̀wò fáìlì tí kò ní àbùkù; wíwọlé omi nígbà gbogbo. | Clear float switch; inspect/replace check valve; address source of continuous water. |
| Pump runs but no water discharges. | Discharge pipe clogged or frozen; impeller clogged; air lock. | Clear discharge pipe; clean impeller; prime pump by ensuring it's fully submerged and free of air. |
| Awọn iyipo fifa soke nigbagbogbo. | Sump basin too small; float switch set too low; backflow from discharge pipe. | Consider larger basin; adjust float switch tether; install/check check valve. |
If problems persist after attempting these solutions, please contact Everbilt customer support.
Awọn pato
| Brand | Lailai |
| Nọmba awoṣe | HDPS50W |
| Agbara ẹṣin | 0.5 HP |
| Voltage | 115 Volts |
| Ampigba | 5.2 A |
| Orisun agbara | AC |
| Ohun elo Ile | Aluminiomu |
| Ohun elo Impeller | Thermoplastic (Plastic) |
| Iwon Ifijiṣẹ | 1-1 / 2 ni FNPT |
| Okun Gigun | 8.25 ft. |
| Iru Yipada Pump | Tethered leefofo Yipada |
| Max. Flow Rate (0 ft.) | 2800 GPH (gallons/hour) |
| Flow Rate (10 ft.) | 2400 GPH (gallons/hour) |
| Flow Rate (15 ft.) | 2100 GPH (gallons/hour) |
| Gíga Pípù Tó Gíga Jùlọ | 24 ft. |
| Awọn iwọn Ọja (L x W x H) | 8.27" x 6.3" x 10.63" |
| Iwọn Ọja | 8.8 lbs |
| Iwọn otutu Ṣiṣẹ Kere | 35°F |
| Iwọn otutu ti o pọju | 100°F |
| Awọn iwe-ẹri | CSA Ifọwọsi |
Atilẹyin ọja ati Support
For warranty information or technical support, please contact Everbilt customer service. Keep your purchase receipt as proof of purchase for any warranty claims.
Fun iranlọwọ siwaju sii, o le ṣabẹwo si Everbilt brand page on Amazon or consult the retailer where the product was purchased.