1. Ifihan
The DAB FEKA 300 MA is a robust submersible pump designed for efficient drainage and lifting of clear, grey, or rainwater in various settings, including domestic and residential environments. This pump is capable of handling moderately dirty water containing solids up to 25mm in diameter. Its versatile design makes it suitable for both fixed and mobile installations. The FEKA 300 MA features an integrated float switch for automatic operation and is engineered to run dry for up to 1 minute without damage.
2. Alaye Aabo
- Always disconnect the pump from the power supply before any installation, maintenance, or cleaning operations.
- Ensure the power cable is intact and free from damage. Do not use the pump if the cable is damaged.
- Awọn fifa gbọdọ wa ni ilẹ daradara.
- Do not operate the pump in explosive atmospheres or with flammable liquids.
- Pa awọn ọmọde ati awọn oṣiṣẹ laigba aṣẹ kuro ni agbegbe iṣẹ.
- Ensure the pump is fully submerged during operation to prevent overheating, except for the specified 1-minute dry run capability.
3. Eto
- Ṣii silẹ: Carefully remove the pump and all accessories from the packaging. Inspect for any signs of damage.
- Asopọ sisilẹ: Connect a suitable discharge hose to the pump's outlet. Ensure a secure, watertight connection. The pump is designed with a discharge outlet for easy hose attachment.
- Àtúnṣe Ìyípadà Lílefó: The pump features an integrated float switch for automatic operation. Adjust the cable length of the float switch to set the desired start and stop levels for the pump. The pump will start when the water level rises and lift the float, and stop when the water level drops and the float falls.
- Ibi: Place the pump on a stable, flat surface in the area to be drained. Ensure the suction grille is clear of obstructions.
- Asopọ agbara: Connect the pump to a suitable power outlet. Ensure the power supply matches the pump's requirements (230V ~ 50Hz).

4. Awọn ilana Iṣiṣẹ
- Isẹ aladaaṣe: Once connected to power and placed in water, the pump will automatically start when the water level reaches the activation point of the float switch. It will continue to pump until the water level drops below the deactivation point.
- Iṣẹ afọwọṣe (ti o ba wulo): If your model supports manual operation (without a float switch or with a manual override), ensure the pump is continuously monitored to prevent dry running for extended periods.
- Abojuto: Periodically check the pump's operation and the water level to ensure proper functioning.
5. Itọju
- Ninu igbagbogbo: Periodically clean the pump's suction grille to remove any debris, leaves, or solids that may obstruct water intake.
- Ayewo: Regularly inspect the power cable, float switch, and pump body for any signs of wear, damage, or corrosion.
- Ibi ipamọ igba otutu: If storing the pump for an extended period, especially in freezing temperatures, ensure it is thoroughly cleaned, drained of all water, and stored in a dry, frost-free location.
- Iṣẹ Ọjọgbọn: For any internal repairs or complex issues, contact a qualified service technician.
6. Laasigbotitusita
- Pump ko bẹrẹ: Check the power supply, ensure the plug is securely inserted, and verify that the float switch is not stuck in the 'off' position (if applicable).
- Pump runs but no water is discharged: Check for blockages in the suction grille or discharge hose. Ensure the water level is sufficient for the pump to operate.
- Reduced flow rate: Clean the suction grille and check the discharge hose for kinks or partial blockages.
- Pọ́ọ̀pù náà dúró láìròtẹ́lẹ̀: Check for thermal overload protection activation (allow to cool down). Verify the float switch position.
7. Awọn pato
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Olupese | DAB fifa |
| Nọmba awoṣe | FEKA 300 |
| Ọja Mefa | 18.9 x 30.3 x 32.9 cm |
| Iwọn Nkan | 4.6 kilo |
| Àwọ̀ | Black / Alawọ ewe |
| Ara | Submersible |
| Material (Pump Body) | Technopolymer |
| Material (Motor Casing/Shaft) | AISI 304 Stainless Steel / AISI 431 Steel |
| Orisun agbara | Okun Itanna |
| Flow Rate (Min/Max) | 1 m³/h to 16 m³/h |
| Max Ori | 7.5 Mita |
| Max Immersion Depth | 7 Meters (with adequate cable length) |
| Olomi Iru | Wastewater, Dirty Water, Rainwater |
| Free Passage for Solids | 25 mm |
| Minimum Suction Level | 38 mm |
| Liquid Temperature (Domestic Use) | +0°C si +35°C |
| Liquid Temperature (Other Uses) | +0°C si +50°C |
| Motor Idaabobo Rating | IP68 |
8. Atilẹyin ọja ati Support
Àwọn àlàyé ìdánilójú pàtó àti ìwífún ìbáṣepọ̀ ìtìlẹ́yìn ni a sábà máa ń fúnni pẹ̀lú àpótí ọjà tàbí lórí ilé iṣẹ́ olùpèsè. website. Please refer to the documentation included with your purchase for precise warranty terms and conditions. For technical assistance or service inquiries, contact DAB PUMPS customer support.
9. Awọn fidio ọja
No relevant product videos from the seller were found for this specific model in the provided data. Please refer to the manufacturer's webaaye tabi oju-iwe ọja fun eyikeyi awọn orisun fidio ti o wa.