1. Ifihan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your DAB FEKA 600 MA submersible pump. Please read this manual thoroughly before using the pump and keep it for future reference.
The DAB FEKA 600 MA is a robust submersible pump designed for draining and lifting light wastewater, greywater, and rainwater in domestic and residential environments. It is suitable for both fixed and mobile installations.
2. Alaye Aabo
Always observe the following safety precautions to prevent personal injury and damage to the pump.
- Aabo Itanna: Ensure the power supply matches the pump's specifications. Always disconnect power before performing any maintenance or installation. Do not operate the pump with a damaged power cord.
- Aabo omi: Never touch the pump or the water it is pumping while it is connected to power. This pump is designed for water only; do not use it for flammable, corrosive, or explosive liquids.
- Fifi sori: Install the pump in a well-ventilated area. Ensure the pump is stable and cannot tip over. Do not lift the pump by its power cable.
- Awọn ọmọde ati awọn ohun ọsin: Pa awọn ọmọde ati awọn ohun ọsin kuro ni fifa soke ati agbegbe iṣẹ rẹ.
- Itọju: Only qualified personnel should perform repairs. Use only genuine replacement parts.
3. Ọja Ipariview
The DAB FEKA 600 MA pump is engineered for reliability and durability, featuring high-quality materials and a robust design.

Figure 3.1: DAB FEKA 600 MA Submersible Pump - Front View.

Figure 3.2: Key Features of the DAB FEKA 600 MA Pump. This diagram highlights the automatic start/stop float arm, durable construction materials, a flow rate of 15,000 liters per hour, a maximum head of 9 meters, and the ability to handle solids up to 25mm. Note: Official specifications for flow rate and head are provided in Section 8.
3.1 Awọn paati bọtini
- Ara fifa: Constructed from technopolymer for durability.
- Suction Grille: Designed for efficient intake and handling of solids.
- Mọto: Asynchronous submersible motor for continuous duty, with integrated thermal protection for single-phase versions. Made of AISI 304 stainless steel with an AISI 431 steel shaft for corrosion resistance.
- Yiyi leefofo loju omi: Integrated float switch for automatic operation (in automatic versions).
- Triple Seal System: Oil bath triple seal for enhanced reliability.
3.2 Awọn ohun elo
The FEKA 600 MA pump is suitable for various applications, including:

Figure 3.3: Common Applications for the DAB FEKA 600 MA Pump. This image illustrates its use for emptying crawl spaces, pumping dirty water, dewatering construction sites, and managing rainwater.
- Draining crawl spaces
- Pumping dirty water and greywater
- Dewatering construction sites
- Managing rainwater
4. Eto ati fifi sori
Proper installation is crucial for the pump's performance and longevity. Follow these steps carefully.
4.1 Akojọ aṣyn fifi sori ẹrọ tẹlẹ
- Ensure the installation site is clear of debris and has adequate space.
- Daju awọn ipese agbara voltage and frequency match the pump's requirements.
- Prepare the discharge pipe and any necessary fittings.
4.2 fifi sori Igbesẹ
- Ipo ti fifa soke naa: Place the pump on a stable, flat surface in the lowest part of the area to be drained. Ensure the suction grille is not obstructed. The minimum admission level is 38 mm.
- Connecting the Discharge Pipe: Attach a suitable discharge pipe to the pump's outlet. Ensure all connections are watertight. The pump has a 1 1/4" G threaded outlet.
- Float Switch Adjustment (for automatic versions): Adjust the float switch cable length to set the desired ON/OFF levels. Ensure the float can move freely without obstruction.
- Asopọ agbara: Connect the pump to a grounded electrical outlet. Ensure the circuit is protected by a residual current device (RCD).
- Idanwo: Before full operation, perform a test run to ensure the pump activates and deactivates correctly and that there are no leaks.
For detailed technical specifications and installation diagrams, refer to the official technical sheet: DAB FEKA Technical Sheet.
5. Awọn ilana Iṣiṣẹ
The DAB FEKA 600 MA pump is designed for straightforward operation.
5.1 Automatic Operation (with float switch)
- Ensure the pump is properly installed and connected to power.
- The pump will automatically start when the water level rises and lifts the float switch.
- The pump will automatically stop when the water level drops and the float switch returns to its lower position.
5.2 Manual Operation (without float switch or for specific tasks)
For manual versions or when bypassing the float switch:
- Connect the pump to power. The pump will begin operating immediately.
- Monitor the water level to prevent the pump from running dry for extended periods. The pump can run dry for up to 1 minute without damage.
- Disconnect the pump from power to stop operation.
Pataki: Do not allow the pump to run dry for more than 1 minute. Prolonged dry running can cause damage.
6. Itọju
Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect the pump from the power supply before any maintenance.
6.1 Ninu fifa soke
- Periodically inspect the suction grille for blockages from debris, leaves, or other solids. Clean as necessary.
- Rinse the pump with clean water after use, especially if pumping heavily contaminated liquids.
6.2 Winter Ibi ipamọ
If the pump will not be used for an extended period or during freezing temperatures:
- Drain all water from the pump and discharge pipe.
- Mu fifa soke daradara.
- Tọju fifa soke ni ibi gbigbẹ, ti ko ni otutu.
6.3 Ọjọgbọn Iṣẹ
For internal components, motor, or seal inspection, it is recommended to contact a qualified service technician. Do not attempt to disassemble the motor housing.
7. Laasigbotitusita
Ṣaaju ki o to kan si atilẹyin, tunview awọn oran ti o wọpọ wọnyi ati awọn ojutu wọn.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Pump ko bẹrẹ. | Ko si ipese agbara. Float switch stuck (automatic version). Gbona apọju Idaabobo mu ṣiṣẹ. | Ṣayẹwo asopọ agbara ati fifọ Circuit. Clear any obstructions around the float switch. Allow pump to cool down; it should reset automatically. |
| Pọ́ọ̀pù náà ń ṣiṣẹ́ ṣùgbọ́n omi kò jáde. | Suction grille blocked. Discharge pipe blocked or kinked. Air lock in the pump. | Disconnect power and clear the suction grille. Check and clear the discharge pipe. Submerge the pump completely and shake gently to release air. |
| Yiyi fifa soke tan ati pa nigbagbogbo. | Float switch incorrectly adjusted. Insufficient water volume. | Adjust float switch to allow for a larger water level differential. Ensure adequate water volume for continuous operation. |
| Reduced flow rate. | Partial blockage in suction or discharge. Pump wear. | Clean suction grille and check discharge pipe. Kan si oṣiṣẹ iṣẹ ti o peye fun ayewo. |
8. Imọ ni pato
Detailed specifications for the DAB FEKA 600 MA pump.
| Paramita | Iye |
|---|---|
| Awoṣe | FEKA 600 MA |
| Agbara | 0.70 HP |
| Voltage | 230 V (2.3E+2 Volts) |
| Oṣuwọn Sisan ti o pọju | 16 m³/h (16,000 liters/hour) |
| Max Ori | 7.5 m |
| Max Immersion Depth | 7 m |
| Pumped Liquid Type | Wastewater and Rainwater |
| Free Passage of Solids | 25 mm |
| Min Admission Level | 38 mm |
| Liquid otutu Range | +0°C to +35°C (domestic use) +0°C to +50°C (other uses) |
| Kilasi Idaabobo | IP68 |
| Ohun elo | Technopolymer body, Stainless Steel motor (AISI 304), Steel shaft (AISI 431) |
| Awọn iwọn (isunmọ.) | 43.4 x 26 x 19.8 cm (Apapọ) 43 x 21 x 29 cm (Pump) |
| Ìwọ̀n (isunmọ́.) | 6.24 kg |
For complete technical details, please refer to the official product documentation provided by DAB PUMPS.
9. Atilẹyin ọja ati Support
Information regarding product warranty and customer support.
9.1 atilẹyin ọja Alaye
Specific warranty terms and conditions are typically provided with your purchase documentation or can be found on the manufacturer's official webojula. Jọwọ ṣe idaduro ẹri rira rẹ fun awọn iṣeduro atilẹyin ọja.
9.2 Onibara Support
For technical assistance, spare parts, or service inquiries, please contact your authorized DAB PUMPS dealer or visit the official DAB PUMPS webojula fun alaye olubasọrọ.
Official commercial profile of the Feka range: DAB FEKA Commercial Profile.