1. Ifihan
This manual provides essential instructions for the safe and efficient operation, maintenance, and care of your NutriBullet NB50100C Pro 1000 Single Serve Blender. Please read this manual thoroughly before first use and retain it for future reference.

Nọmba 1.1: The NutriBullet Pro 1000 Single Serve Blender with a cup filled with ingredients and another with a blended smoothie.
2. Alaye Aabo pataki
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury. Read all instructions.
- Ma ṣe fi omi mimọ sinu omi tabi awọn olomi miiran.
- Yago fun olubasọrọ pẹlu gbigbe awọn ẹya ara.
- Ma ṣe ṣiṣẹ ohun elo eyikeyi pẹlu okun ti o bajẹ tabi plug.
- Yọọ pulọọgi kuro ni iṣan jade nigbati o ko ba wa ni lilo, ṣaaju fifi sii tabi mu awọn ẹya kuro, ati ṣaaju ṣiṣe mimọ.
- Maṣe lo ni ita.
- Ma ṣe jẹ ki okun duro lori eti tabili tabi counter.
- Ma ṣe gbe sori tabi sunmọ gaasi ti o gbona tabi ina ina, tabi ni adiro ti o gbona.
- Always operate the blender on a flat, stable surface.
- Do not fill ingredients past the MAX line indicated on the cup.
- Awọn abẹfẹlẹ jẹ didasilẹ. Mu pẹlu itọju.
3. Package Awọn akoonu
Your NutriBullet Pro 1000 7-piece set includes the following components:
- 1000-Watt Motor Mimọ
- Extractor Blade
- 30 Fl Oz Cup
- Si-Lọ ideri
- Lip Ring
- Afowoyi Olumulo (iwe-ipamọ yii)
- Recipe Guide (may vary by package)

Nọmba 3.1: Main components of the NutriBullet Pro 1000 Blender.
4. Eto
Before first use, wash all parts except the motor base with warm soapy water. Rinse and dry thoroughly.
- Gbe ipilẹ mọto sori mimọ, gbẹ, ati dada ipele.
- Ensure the motor base is unplugged from the power outlet.
- Add your desired ingredients to the NutriBullet cup. Do not exceed the MAX fill line.
- Twist the Extractor Blade onto the cup until it is securely tightened.
- Invert the cup and blade assembly onto the motor base. Align the three tabs on the cup with the three slots on the motor base.
- Press down and twist the cup clockwise to activate the blending cycle.

Nọmba 4.1: The NutriBullet Pro 1000 motor base.
5. Awọn ilana Iṣiṣẹ
The NutriBullet Pro 1000 features a powerful 1000-watt motor designed for efficient blending.
5.1 Blending Cycle
- After assembling the cup and blade onto the motor base as described in Section 4, plug the power cord into a 110V electrical outlet.
- Press down firmly on the cup and twist clockwise until the tabs lock into place. The blender will begin operating.
- The blending cycle will run automatically for approximately 60 seconds and then shut off. For shorter blending times, simply twist the cup counter-clockwise and lift to stop.
- Once blending is complete, twist the cup counter-clockwise and lift it off the motor base.
- Unscrew the Extractor Blade from the cup.
- Attach the Lip Ring or To-Go Lid to the cup if desired.
5.2 idapọmọra Tips
- For best results, add liquids first, then soft ingredients, and finally harder ingredients or ice.
- If blending becomes difficult, add more liquid.
- Do not continuously blend for more than 1 minute. Allow the motor to rest for a few minutes between cycles.
- Ensure the cup is securely attached to the motor base to prevent leaks.

Nọmba 5.1: The NutriBullet Pro 1000 Blender prepared for operation with ingredients.
6. Ninu ati Itọju
Proper cleaning ensures the longevity and optimal performance of your NutriBullet blender.
6.1 Cleaning the Extractor Blade and Cups
- Immediately after each use, rinse the Extractor Blade and cups under warm running water.
- For a deeper clean, wash with warm soapy water using a dish brush to remove any residue.
- The cups and Extractor Blade are top-rack dishwasher safe.
- Iṣọra: Awọn abẹfẹlẹ jẹ didasilẹ. Mu pẹlu awọn iwọn itoju.
6.2 Nmu ipilẹ mọto naa mọ
- Yọọ ipilẹ mọto ṣaaju ki o to di mimọ.
- Pa mọto mimọ pẹlu ipolowoamp cloth. If necessary, use a mild soap.
- Ma ṣe fi omi mimọ sinu omi tabi omi miiran.
- Ensure the motor base is completely dry before plugging it back in or storing.
7. Laasigbotitusita
If you encounter issues with your NutriBullet Pro 1000, refer to the following common problems and solutions:
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Blender ko ni tan-an. | Not plugged in; cup not properly engaged. | Ensure power cord is securely plugged in. Twist cup firmly clockwise onto the motor base until locked. |
| Leaking during blending. | Blade not tightened; ingredients over MAX line. | Ensure Extractor Blade is securely twisted onto the cup. Do not fill ingredients past the MAX line. |
| Motor ma duro nigba isẹ ti. | Overheating; too many ingredients; too thick consistency. | Unplug and let cool for 15-20 minutes. Reduce ingredients or add more liquid. Do not blend continuously for more than 1 minute. |
| Ariwo ariwo tabi olfato dani. | Foreign object; motor strain. | Immediately unplug. Check for obstructions. If problem persists, discontinue use and contact customer support. |
8. Awọn pato
| Ẹya ara ẹrọ | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Brand | NutriBullet |
| Nọmba awoṣe | NB50100C |
| Orisun agbara | Okun Itanna |
| Ọkọ ayọkẹlẹ Wattage | 1000 Wattis |
| Voltage | 110V |
| Agbara | 30 Fl Oz (2140.95 Grams) |
| Pataki Ẹya | Nikan Sin |
| Blade elo | Irin ti ko njepata |
| Ohun elo Iru Ọfẹ | BPA Ọfẹ |
| Ọja Mefa | 5.47"D x 5.51"W x 14.88"H |
| Iwọn Nkan | 4.72 iwon |
9. Atilẹyin ọja ati Support
Your NutriBullet NB50100C Pro 1000 Single Serve Blender comes with a Atilẹyin ọja to lopin. For specific details regarding the warranty coverage, duration, and terms, please refer to the warranty card included with your product or visit the official NutriBullet webojula.
For technical support, replacement parts, or any other inquiries, please contact NutriBullet Customer Service. Contact information can typically be found on the official NutriBullet webaaye tabi lori apoti ọja.