1. Ifihan
The Klein Tools CL120 Digital Clamp Meter is an automatically ranging digital clamp-meter designed for professional and DIY electrical tasks. It measures AC current and Non-Contact Voltage (NCVT) via the clamp, ati AC/DC voltage, resistance, and continuity via test-leads. This manual provides essential information for safe and effective operation of your CL120 Digital Clamp Mita.
2. Alaye Aabo
WARNING: Risk of electric shock or personal injury.
- Nigbagbogbo wọ aabo oju ti a fọwọsi.
- Ma ṣe lo ti mita tabi awọn idari idanwo ba han bajẹ.
- Ma ṣe lo lori awọn iyika ti o kọja iwọn voltage ati lọwọlọwọ-wonsi.
- Ensure the meter is turned OFF before connecting or disconnecting test leads.
- Lo iṣọra nigbati o ba n ṣiṣẹ pẹlu awọn iyika laaye.
- Refer to local and national safety codes.
3. Package Awọn akoonu
- CL120 Digital Clamp Mita
- Ọran gbigbe
- Test Leads with CAT III/CAT IV Safety Caps
- 3 x AAA batiri
- Ilana itọnisọna

4. Awọn ẹya Ọja
- Wapọ Clamp Mita: Measures AC current and NCVT via clamp; AC/DC voltage, resistance, and continuity via test-leads.
- Non-Olubasọrọ Voltage Idanwo: Integrated into the clamp jaw for convenient electrical testing.
- Ifihan Afẹyinti: LCD shows clear readings in low-light conditions for enhanced visibility.
- Awọn wiwọn to peye: Auto-ranging technology selects the appropriate measurement range for accurate results.
- Awọn ẹya Rọrun: Test lead holder on the side of the clamp fun ọwọ-free isẹ.
- Awọn ẹya afikun: Max, Data Hold capability for enhanced functionality and auto-power off after 10 minutes to conserve battery life.

5. Eto
5.1 Fifi sori batiri
- Rí i dájú pé mita náà ti pa.
- Using a Phillips head screwdriver, loosen the screw on the battery compartment cover located on the back of the meter.
- Remove the cover and insert 3 AAA batteries, observing correct polarity.
- Ropo ideri kompaktimenti batiri ki o si Mu dabaru.

5.2 Igbeyewo asiwaju Asopọ
Connect the red test lead to the VΩmA input jack and the black test lead to the COM input jack for voltage, resistance, ati awọn wiwọn lilọsiwaju.

6. Awọn ilana Iṣiṣẹ
6.1 Agbara Tan / Pa
Rotate the function dial from the OFF position to any desired measurement function to power on the meter. Rotate the dial back to OFF to power off.
6.2 AC Wiwọn lọwọlọwọ (Clamp)
- Rotate the function dial to the 2/20A~ or 200/400A~ position.
- Ṣii clamp ẹnu nípa títẹ ohun tí ń fa ìfàsẹ́yìn náà.
- Gbe awọn clamp jaw around a single conductor (not a power cord with multiple wires) to measure AC current.
- Ka iye lọwọlọwọ lori ifihan naa.


6.3 AC / DC Voltage Measurement (Test Leads)
- Rotate the function dial to the V~ (AC Voltage) tabi V- (DC Voltage) ipo.
- Connect the test leads to the circuit points you wish to measure.
- Ka voltage iye lori ifihan.

6.4 Wiwọn resistance ati Itẹsiwaju
- Rotate the function dial to the Ω (Resistance) or Continuity position.
- So awọn itọsọna idanwo kọja paati tabi iyika lati wọn.
- For continuity, the meter will beep if a continuous path is detected. For resistance, read the value on the display.
6.5 Non-olubasọrọ Voltage (NCV) erin
Press the NCV button and hold the meter's tip near a live AC voltage source. The meter will emit an audible beep and the NCV indicator light will illuminate if AC voltage ti ri.
6.6 Backlight and Data Hold/Max Functions
- Imọlẹ ẹhin: Press the backlight button to illuminate the display for better visibility in low-light conditions.
- Idaduro data: Press the HOLD button to freeze the current reading on the display. Press again to release.
- O pọju: Press the MAX button to capture the maximum reading during a measurement.
7. Itọju
7.1 Ninu
Wipe the meter with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
7.2 Batiri Rirọpo
Replace batteries when the low battery indicator appears on the display. Refer to section 5.1 for battery installation instructions.
8. Laasigbotitusita
- Mita ko ni agbara lori: Ṣàyẹ̀wò fífi bátìrì sílẹ̀ kí o sì rí i dájú pé àwọn bátìrì náà kò tán.
- Awọn kika ti ko pe: Ensure test leads are properly connected and the correct function is selected. Verify the circuit is within the meter's specified range.
- Ko si ariwo itesiwaju: Ensure the circuit is de-energized and the component is not open.
9. Awọn pato
| Sipesifikesonu | Iye |
|---|---|
| Brand | KLỌN irinṣẹ |
| Nọmba awoṣe | CL120 |
| Orisun agbara | Battery Powered (3 x AAA included) |
| AC Lọwọlọwọ Range | 400 Amp |
| AC/DC Voltage Ibiti | Títí dé 600 Volts |
| Resistance Range | Titi di 20 MΩ |
| Itesiwaju | Bẹẹni |
| Non-Olubasọrọ Voltage (NCV) | Bẹẹni |
| Ifihan Backlit | Bẹẹni |
| Gbigbe Aifọwọyi | Bẹẹni |
| Data Hold / Max | Bẹẹni |
| Aabo Rating | Nran III 600V |
| Iwọn Nkan | 9.8 iwon (0.61 iwon) |
| Awọn iwọn Ọja (L x W x H) | 8.45 x 3.51 x 1.51 inches |
10. Awọn fidio ọja osise
Video 1: A comprehensive review of the Klein Tools CL120 Digital Clamp Meter, demonstrating its features and practical applications, including use with a line splitter.
Video 2: An informational video covering essential aspects and functionalities of the Klein Tools Clamp Mita.
Video 3: A showcase of Klein Tools Digital Clamp Meters, highlighting their robust design and various measurement capabilities.
Video 4: A comparison between the Klein Tools CL120 and CL390 clamp meters, helping users decide which model best suits their needs.
Video 5: A alaye review assessing the value and performance of the Klein Tools CL120 Digital Clamp Mita.
Video 6: A demonstration of the Klein Digital Clamp Meter in various electrical testing scenarios.
11. Atilẹyin ọja ati Support
Klein Tools products are manufactured to high standards of quality and durability. For warranty information, product registration, or technical support, please visit the official Klein Tools webojula tabi kan si wọn onibara iṣẹ. Tọju iwe-ẹri rira rẹ fun awọn ẹtọ atilẹyin ọja.
For further assistance, please refer to the contact information provided on the official Klein Tools webojula: www.kleintools.com