1. Ọja Ipariview
This manual provides detailed instructions for the installation, operation, and maintenance of your COMFEE CF-CFW12A 12000 BTU Monosplit Air Conditioner Kit. This system is designed for wall installation and features inverter technology for efficient cooling and heating.
Awọn ẹya pataki pẹlu:
- Cooling Capacity: 12000 BTU (3.52 kW)
- Heating Capacity: 13000 BTU (3.81 kW)
- Energy Efficiency Class (Cooling): A++
- Energy Efficiency Class (Heating): A+
- Integrated Dehumidifier Function
- Night Function for optimized sleep comfort
- Utilizes R-32 Refrigerant
2. Alaye Aabo pataki
Read all safety warnings and instructions carefully before installing or operating this appliance. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Ti beere fifi sori Ọjọgbọn: This air conditioning system requires professional installation by a qualified technician. Do not attempt to install the unit yourself.
- Aabo Itanna: Ensure the power supply matches the specifications of the unit. Do not use extension cords or multiple outlet adapters. Always disconnect power before performing any maintenance or cleaning.
- Imudani firiji: This unit contains R-32 refrigerant, which is mildly flammable. Only qualified personnel should handle refrigerant. Do not puncture or burn the refrigerant circuit.
- Awọn ọmọde ati Awọn eeyan Alailagbara: Ohun elo yii kii ṣe ipinnu fun lilo nipasẹ awọn eniyan (pẹlu awọn ọmọde) pẹlu idinku ti ara, imọlara tabi awọn agbara ọpọlọ, tabi aini iriri ati imọ, ayafi ti wọn ba ti fun wọn ni abojuto tabi itọnisọna nipa lilo ohun elo nipasẹ eniyan ti o ni iduro fun aabo wọn.
- Afẹfẹ: Ensure proper ventilation around both indoor and outdoor units to prevent overheating and ensure efficient operation.
- Itọju: Only perform maintenance tasks described in this manual. For complex repairs, contact a qualified service technician.
3. Package Awọn akoonu
Your COMFEE CF-CFW12A air conditioner kit includes the following main components:
- Indoor Unit (CF-CFW12A IU)
- Outdoor Unit (CF-CFW12A OU)
- Isakoṣo latọna jijin
- Afowoyi Olumulo (iwe-ipamọ yii)
- Installation Accessories (e.g., mounting plate, refrigerant lines, electrical cables - specific items may vary by kit)

Nọmba 3.1: COMFEE CF-CFW12A Indoor Unit. This unit is designed for wall mounting inside the room to be conditioned.

Nọmba 3.2: COMFEE CF-CFW12A Outdoor Unit. This unit houses the compressor and condenser, and is installed outside.

Nọmba 3.3: Remote Control for COMFEE Air Conditioner. Used to adjust settings and modes.
4. Fifi sori ẹrọ ati Oṣo
The installation of the COMFEE CF-CFW12A monosplit air conditioner requires specialized knowledge and tools. It must be performed by a certified professional. Attempting self-installation may void your warranty and lead to improper operation or safety hazards.
4.1. Professional Installation Steps (Overview for User Information)
- Aṣayan Aaye: The technician will choose optimal locations for both the indoor and outdoor units, considering factors like airflow, structural support, drainage, and proximity to power.
- Gbigbe Ẹka inu inu: The indoor unit's mounting plate is securely fixed to the wall.
- Gbigbe Ẹka Ita gbangba: The outdoor unit is placed on a stable, level surface or mounted on a wall bracket, ensuring adequate clearance for airflow.
- Pipa omi firiji: Copper pipes are connected between the indoor and outdoor units to form the refrigerant circuit. This involves flaring, connecting, and vacuuming the lines to remove moisture and air.
- Asopọmọra ṣiṣan: A drain hose is connected to the indoor unit to remove condensed water, ensuring proper slope for gravity drainage.
- Asopọmọra Itanna: Power cables and communication wires are connected between the units and to the main power supply, following local electrical codes.
- Leak Test and Commissioning: After all connections are made, the system is checked for leaks, refrigerant is released into the system, and the unit is tested for proper operation in all modes.
For detailed installation instructions, please refer to the separate installation manual provided to your professional installer.
5. Awọn ilana Iṣiṣẹ
The COMFEE CF-CFW12A air conditioner is operated primarily using the wireless remote control. Ensure batteries are correctly inserted into the remote control.
5.1. Awọn iṣẹ Iṣakoso latọna jijin
Refer to Figure 3.3 for a visual guide to the remote control buttons.
- Bọtini AGBARA: Tẹ lati tan-an tabi PA kuro.
- Bọtini MODE: Cycles through operating modes: AUTO, COOL, DRY, FAN, HEAT.
- IGBE ▲ / ▼ Awọn bọtini: Ṣe atunṣe eto iwọn otutu ti o fẹ.
- Bọtini FAN: Selects fan speed: AUTO, LOW, MED, HIGH.
- Bọtini SWING: Controls the vertical louver movement for air direction.
- Bọtini TIMER: Ó ń ṣètò aago ON/PA fún iṣẹ́ aládàáṣe.
- Bọtini Orun: Activates the Sleep mode, which adjusts temperature gradually for comfort during sleep and saves energy.
- Bọtini ECO: Activates energy-saving mode (if available).
- Bọtini TURBO: Ó ń mú kí ìtútù tàbí ìgbóná tó pọ̀ jùlọ ṣiṣẹ́ fún ìyípadà iwọ̀n otútù kíákíá.
5.2. Ipilẹ isẹ
- Tan-an: Press the POWER button. The unit will start in the last selected mode or AUTO mode.
- Yan Ipo: Press the MODE button repeatedly until your desired mode (COOL, HEAT, DRY, FAN) is displayed.
- Ṣeto iwọn otutu: Use the TEMP ▲ or ▼ buttons to set your preferred temperature.
- Ṣatunṣe Iyara Fan: Tẹ bọtini FAN lati yan iyara afẹfẹ ti o fẹ.
- Paa: Tẹ bọtini AGBARA lẹẹkansi.
6. Itọju
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always disconnect power to the unit before performing any maintenance.
6.1. Air Filter Cleaning
The air filters should be cleaned every two weeks or more frequently depending on usage and air quality.
- Ṣii iwaju iwaju ti ẹyọ inu inu.
- Yọ awọn asẹ afẹfẹ kuro.
- Pa awọn asẹ mọ nipa lilo ẹrọ igbale tabi wẹ wọn pẹlu omi tutu (ni isalẹ 40°C).
- Allow the filters to dry completely in a shaded area before reinstalling. Do not expose to direct sunlight.
- Tun fi awọn asẹ naa sori ẹrọ ki o si ti iwaju panẹli naa.
6.2. Ìmọ́tótó Ẹ̀yà Ìta
The outdoor unit should be cleaned periodically to remove dust, leaves, and debris that can accumulate on the coils and fan blades. This should ideally be done by a professional technician.
- Ensure the power supply to the outdoor unit is disconnected.
- Carefully remove any visible debris from the coil fins and fan area.
- Do not bend the coil fins. If they are bent, gently straighten them with a fin comb.
- Yago fun fifa omi taara sori awọn paati itanna.
6.3. Awọn sọwedowo igba
- Before Summer/Winter: Have a professional technician inspect the refrigerant levels, electrical connections, and overall system performance.
- Long Periods of Non-Use: If the unit will not be used for an extended period, operate it in FAN mode for a few hours to dry the internal components and prevent mold growth. Disconnect the power supply.
7. Laasigbotitusita
Ṣaaju ki o to kan si iṣẹ, tunview awọn oran ti o wọpọ wọnyi ati awọn ojutu wọn.
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Ẹka ko bẹrẹ | Ko si ipese agbara Remote control batteries dead Ti mu iṣẹ aago ṣiṣẹ | Ṣayẹwo asopọ agbara ati fifọ Circuit Rọpo awọn batiri isakoṣo latọna jijin Fagilee eto aago |
| Insufficient itutu / alapapo | Dirty air filters Àwọn fèrèsé/ìlẹ̀kùn ṣí sílẹ̀ Eto iwọn otutu ko tọ Outdoor unit obstructed | Mọ air Ajọ Pa ferese ati ilẹkun Ṣatunṣe eto iwọn otutu Clear obstructions around outdoor unit |
| Sisọ omi lati inu ile | Drain hose clogged or bent Indoor unit not level | Check and clear drain hose Ensure indoor unit is level (professional service) |
| Awọn ariwo dani | Àwọn ohùn ìṣiṣẹ́ déédéé (fún àpẹẹrẹ, ìṣàn omi inú itutu) Awọn ẹya alaimuṣinṣin Idilọwọ àìpẹ | No action required for normal sounds Contact professional service for inspection |
| Isakoṣo latọna jijin ko ṣiṣẹ | Awọn batiri ti ku tabi fi sii lọna ti ko tọ Idilọwọ laarin latọna jijin ati ẹyọkan | Replace batteries, ensure correct polarity Remove obstructions, ensure direct line of sight |
Ti iṣoro naa ba wa lẹhin igbiyanju awọn ojutu wọnyi, jọwọ kan si onimọ-ẹrọ iṣẹ ti o peye.
8. Awọn alaye ọja
The following table outlines the technical specifications for the COMFEE CF-CFW12A air conditioner kit.
| Ẹya ara ẹrọ | Sipesifikesonu |
|---|---|
| Brand | COMFEE |
| Nọmba awoṣe | CF-CFW12A |
| Iru | Mini-split Air Conditioner |
| Iru fifi sori ẹrọ | Professional (Wall-mounted) |
| Agbara Itutu | 12000 BTU (3.52 kW) |
| Alapapo Agbara | 13000 BTU (3.81 kW) |
| Energy Efficiency (Cooling) | A++ |
| Energy Efficiency (Heating) | A+ |
| Ipin Iṣiṣẹ Agbara Igba Igba (SEER) | 16 |
| Firiji | R-32 |
| Voltage | 230 Volts |
| Pataki Awọn ẹya ara ẹrọ | Dehumidifier, Heating and Cooling Function, Inverter Technology |
| Àwọ̀ | Funfun |
| Iwọn Nkan | 90 kilograms (Total for kit) |
| Àlẹmọ Iru | Standard àlẹmọ |
| Bẹrẹ Odun | 2020 |
9. Atilẹyin ọja ati Support
9.1. Atilẹyin ọja
COMFEE products are manufactured to high-quality standards. For specific warranty terms and conditions, including coverage period and what is covered, please refer to the warranty card included with your product or consult your retailer at the time of purchase. Keep your proof of purchase for warranty claims.
9.2. Technical Support and Service
If you encounter any issues that cannot be resolved using the troubleshooting guide, or if you require professional service or spare parts, please contact:
- Your authorized COMFEE retailer.
- An authorized COMFEE service center.
When contacting support, please have your product model number (CF-CFW12A) and serial number ready. This information can typically be found on a label on the indoor or outdoor unit.