Apera Instruments EC850 Portable Handheld Conductivity Meter Kit User Manual

Awoṣe: AI5512

1. Ifihan

The Apera Instruments Value Series EC850 Portable Conductivity Meter Kit is engineered for precise conductivity and TDS measurements in various field applications. Its robust design and practical features ensure reliable performance and ease of use for professionals.

2. Ọja Ipariview

2.1 Key Awọn ẹya ara ẹrọ

2.2 Kini ni Apoti

2.3 Ọja irinše

Apera Instruments EC850 Portable Conductivity Meter and Probe

Figure 1: The EC850 meter with its conductivity probe, displaying a measurement of 1413 µS at 25.0°C. The meter is waterproof and features clear buttons for calibration, mode, setup, and power.

Apera Instruments EC850 Portable Conductivity Meter with Kickstand

Figure 2: The EC850 meter shown with its integrated kickstand extended, allowing for convenient benchtop use. The display shows a reading of 1413 µS and 25.0°C.

Apera Instruments Conductivity Probe Connector

olusin 3: Isunmọ view of the conductivity probe's connector, designed for secure attachment to the EC850 meter.

Apera Instruments EC850 Kit in Carrying Case

Figure 4: The complete EC850 Portable Conductivity Meter Kit neatly organized within its durable carrying case, including the meter, probe, and calibration solutions.

Apera Instruments Conductivity Probe Tip

Nọmba 5: Alaye view of the conductivity probe tip, showing the electrodes responsible for accurate measurements.

3. Eto

3.1 Ibẹrẹ Ayẹwo

Upon receiving your EC850 kit, carefully inspect all components for any signs of damage during transit. Ensure all listed items in "What's in the Box" are present.

3.2 Fifi sori batiri

Locate the battery compartment on the back of the meter. Insert the required batteries (typically AA or AAA, refer to the meter's battery compartment for specific type and polarity) ensuring correct orientation. Close the compartment securely.

3.3 Iwadi Asopọ

Connect the conductivity probe to the meter's input port. Ensure the connection is firm and secure to prevent measurement inaccuracies.

3.4 Iṣatunṣe Ibẹrẹ

For optimal accuracy, perform an initial calibration. The EC850 supports 1- to 3-point automatic calibration. Refer to the included quick start guide for detailed steps on using the provided calibration solutions.

4. Awọn ilana Iṣiṣẹ

4.1 Ipilẹ wiwọn

  1. Tan mita naa nipa titẹ bọtini agbara.
  2. Rinse the probe thoroughly with distilled or deionized water before each measurement.
  3. Fi iwadi naa bọ inu sample solution, ensuring the sensor area is fully submerged.
  4. Allow the reading to stabilize on the display. The meter will show conductivity/TDS and temperature.
  5. Record the measurement.
  6. Rinse the probe again after use.

4.2 Lílóye Àwọn Kíkà Ìfihàn

The EC850 display shows the primary measurement (Conductivity in µS/cm or mS/cm, or TDS in ppm) and the temperature in °C. The meter automatically compensates for temperature variations (ATC) to provide accurate readings.

4.3 Self-Diagnosis

The meter features a self-diagnosis function that can alert you to common issues such as calibration errors or probe problems. Follow the on-screen prompts or consult the troubleshooting section for guidance.

5. Itọju

5.1 Fífọ Ìwádìí náà

Regularly clean the conductivity probe to prevent buildup that can affect accuracy. Rinse the probe with distilled water after each use. For stubborn deposits, refer to the detailed cleaning instructions in the full manual or Apera Instruments' support resources.

5.2 Ibi ipamọ

When not in use, store the probe in its protective cap with a small amount of storage solution (or appropriate calibration solution if storage solution is unavailable). Store the meter and probe in a cool, dry place, preferably in its original carrying case.

5.3 Batiri Rirọpo

Replace batteries when the low battery indicator appears on the display. Ensure the meter is turned off before opening the battery compartment. Dispose of old batteries responsibly.

6. Laasigbotitusita

If you encounter issues with your EC850 meter, consult the following common problems and solutions:

IsoroOwun to le FaOjutu
Awọn kika ti ko peDirty probe, expired calibration, incorrect calibration.Clean the probe, recalibrate the meter with fresh solutions, ensure correct calibration procedure.
Mita ko ni tanDead batteries, incorrect battery installation.Replace batteries, check battery polarity.
Awọn kika aiṣedeedeAir bubbles on probe, damaged probe, electrical interference.Gently tap the probe to dislodge bubbles, inspect probe for damage, move away from strong electrical fields.

For more complex issues or persistent problems, please contact Apera Instruments customer support.

7. Awọn pato

IwaẸ̀kúnrẹ́rẹ́
Ọja Mefa13.78 x 10.63 x 3.15 inches; 2.6 iwon
Nọmba Awoṣe NkanAI5512
OlupeseApera Instruments
ASINB083RC3441
Ni akọkọ WaOṣu Kẹta Ọjọ 11, Ọdun 2020
Ingress Idaabobo (IP) RatingIP57 (Mabomire)
IsọdiwọnAutomatic 1- to 3-point
Biinu iwọn otutuAutomatic (ATC)

8. Atilẹyin ọja ati Support

Apera Instruments products are backed by a manufacturer's warranty. For detailed information regarding your product's warranty period, terms, and conditions, please visit the official Apera Instruments webaaye tabi kan si atilẹyin alabara wọn taara.

For technical assistance, troubleshooting, or to purchase replacement parts and accessories, please reach out to Apera Instruments customer service. Contact information can typically be found on their official webaaye tabi laarin apoti ọja.

Olupese: Apera Instruments
Webojula: www.aperainst.com

Awọn iwe aṣẹ ti o jọmọ - AI5512

Ṣaajuview EC850 Portable Conductivity Meter User Manual
User manual for the Apera EC850 portable conductivity meter, detailing its specifications, instrument description, conductivity measurement procedures, parameter settings, what's included, warranty information, and appendices.
Ṣaajuview Apera EC20 Apo Idanwo Conductivity: Ilana itọnisọna & Itọsọna
Iwe itọnisọna pipe fun Apera EC20 Oluṣeto Imudaniloju Apo. Kọ ẹkọ nipa iṣeto, isọdọtun, wiwọn adaṣe, awọn pato imọ-ẹrọ, ati alaye atilẹyin ọja.
Ṣaajuview Apera Instruments EC20 Pocket Conductivity Tester Ilana itọnisọna
Iwe afọwọkọ olumulo fun Apera Instruments EC20 Oluyẹwo Iwa Apo, fifi sori batiri ni wiwa, awọn iṣẹ bọtini foonu, isọdiwọn, wiwọn adaṣe, awọn pato imọ-ẹrọ, ati alaye atilẹyin ọja.
Ṣaajuview Apera Instruments EC400S Portable Conductivity Meter Instruction Manual
Comprehensive instruction manual for the Apera Instruments EC400S Portable Conductivity Meter, covering features, specifications, operation, calibration, sample measurement, maintenance, parameter settings, and USB data communication.
Ṣaajuview APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter Instruction Manual
Comprehensive instruction manual for the APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter, covering specifications, operation, calibration, maintenance, and troubleshooting for laboratory use.
Ṣaajuview Apera SX823-B pH/Conductivity Portable Meter Instruction Manual
This instruction manual provides detailed information on the Apera SX823-B portable pH/Conductivity meter, covering its features, specifications, operation, calibration procedures, maintenance, and troubleshooting.